APPENDIX B
INTERNATIONAL ELECTROTECHNICAL COMMISSION (IEC)
COMPLIANCE
Meets IEC standards 801.2, 801.4 and 801.5 (CE Mark)
Effective January 1996 the European Economic Community will
require that all electronic devices be tested and comply with all
applicable International standards relating to the product type and
category of use. Electromagetic Compatibility Directive 89/336/EEC
specifically addresses communication line surge protection devices,
since conformity to immunity standard EN50082-1:1992 is mandatory.
The EN50082-1:10992 standard incorporates International
Organization for Standardization (ISO) publications 801.2 and 801.4,
which describe Electrostatic Discharge and Electrical Fast Transient
requirements. ISO 801.5 describes Surge Immunity Requirements and
is expected to be adopted as a mandatory requirement under
EN50082-1 by the Technical Committee in 1996. Any protector sold
into the international community must meet these standards. This
device has been tested and found to comply with these standards as
evidenced by its CE mark
Class
1
1.0 kV
24 A
2
1.0 kV
24 A
3
2.0 kV
48 A
4
(n/a)
(n/a)
5
4.0 Kv
95 A
Wave
(1.2 x 50 μs)
Forms
(1.2 x 50 μs)
IEC 801-5 Threat Levels as a Function of Class
Sym. Lines Coupling Mode
Line-GND, Zs=42 Ohms
Figure B-1.
IEC Threat Levels as a Function of Class.
6
Copyright ©
Patton Electronics Company
All Rights Reserved
APPENDIX A
PATTON MODEL 542/543 SPECIFICATIONS
Case:
Molded ABS (black) plastic
Interface:
Coaxial, with one male and one female BNC-type
connector, for CCTV Security Systems, or one male
and one female, or two female F-series connectors
for SATV/CATV Security Systems.
Circuit:
Solid state, bidirectional protection on BNC or F-
series connectors
Primary Circuit
Response Time:
400A (8/20μs wave form )clamped to +/-
12V after 0.2μs.
Surge Capacity:
1.5KW for 1mS
Maximum Clamp Voltage:
12 Volts when subjected to
6kV/3kA test transient
Secondary Circuit
Response Time:
100μs
Surge Capacity:
20kA (8/20μs wave form)
Bandwidth (3dB)
in 50/50 ohms Circuit:
80 Mhz
Series Resistance:
4.3 ohms
Capacitance:
45pf (line-line or line-ground)
Operational/Storage
Temperature:
-55 to +100°C (-67 to 212°F)
Grounding:
External connection provides separate unit-
ground to earth-ground contact
Size:
2.0” long x 1.0” diameter