background image

Buffer Options

The 378S comes factory-configured with different amounts of buffer

memory.  Versions are available with no RAM, 256 KB RAM, and 1 MB
dynamic RAM.  Contact Patton Technical Support at 301-975-1007 for
details on upgrades.

Communication Parameters

Data Rate–  All ports share a common data rate.  The data rate is

selected via DIP SWITCHES for one of five rates: 1200, 2400, 4800,
9600, or 19,200 baud.

Parity–  Even/Odd/None
Word Length– 7 or 8 Bits
Flow Control– Incoming PC data is flow controlled by the switch

using CTS/DSR or XON/XOFF.  This flow control is unidirectional --
only data coming from the PC can be flowed off, not data coming from
the printer

back to the PC.  Transmitted data to the PC consists of

XON/XOFF flow control characters. 

Configuration Switches

Baud Rate- 1200, 2400, 4800, 9600, or 19200
Word Length- 7 or 8 data bits
Parity Enable- Enabled/Disabled
Parity Type- Even/Odd
Stop Bits- 1 or 2
Timeout Interval- 2, 8, 60, 120 seconds
Form Feed at EOJ- Enabled/Disabled

(Note:  The Model 378S has a "paper saver" feature that is active only
when "Form Feed at EOJ" switch is enabled.  When the paper saver
feature is active, the switch monitors whether or not the last character
sent by the selected PC was a form feed.  If it was, the switch will
decline to insert its own form feed character [carriage returns inserted
by the PC after form feed are ignored]).

Power

9.8VAC, 800 MA Wall mount transformer

Size

10”W X 5”D x 1”H (approximate).

APPENDIX B

RS-232C PIN CONFIGURATIONS

1- (FG) Frame Ground
2- (TD) Transmit Data

To Model 378S

3- (RD) Receive Data

From Model 378S

4- (RTS) Request to Send

To Model 378S

5- (CTS) Clear to Send

From Model 378S

6- (DSR) Data Set Ready

From Model 378S

7- (SG) Signal Ground
8- (DCD) Data Carrier Detect

From Model 378S

DIRECTION

MODEL 378S "DCE" SETTING

DIRECTION

1- (FG) Frame Ground
2- (TD) Transmit Data

From Model 378S

3- (RD) Receive Data

To Model 378S

4- (RTS) Request to Send

From Model 378S

5- (CTS) Clear to Send

To Model 378S

7- (SG) Signal Ground

DIRECTION

MODEL 378S "DTE" SETTING

DIRECTION

9

10

To Model 378S

Data Term. Ready (DTR) - 20

Reviews: