6
Model 3087 Quick Start Guide
Connect the serial cable to the ipRocketLink serial port as follows:
1.
Attach the male connector of the serial cable to the female serial connector on the IAD.
2.
Attach the other end of the cable to the serial connector on local serial NTU.
Note
The 3087’s V.35 interface is wired as a DCE. No DTE configuration is possible. If you are directly con-
necting the 3087’s V.35 interface to a third-party equipment that cannot be configured as a DTE, you
must use a tail-circuit cable. You can purchase a tail-circuit cable from a datacom-supply vendor. A tail-
circuit cable will cross-over the necessary V.35 signals so that the two DCE interfaces can communicate.
Note
The 3087’s X.21 interface is default configured as a DCE. Changing the DTE/DCE strap internally can set
the configuration for DTE. The 3087’s X.21 interface requires a cable with a male DB-15 connector.
7.0 Additional Information
For detailed information about configuring and operating guidance, set up procedures, and troubleshooting,
refer to the
ipRocketLink 3086 User Guide
available online at
www.patton.com/manuals/3086.pdf
.