Installation

Select an appropriate location accessible to and within six feet of an AC power
outlet. The outlet must have a ground pin receptacle for product warranty. The DCE-
to-DTE cabling between each attached device and the MSD should be “Straight
Through”, shielded and terminated with male DB-25 connectors. Sub-Channels are
marked “PORT 1” through “PORT 8”; the Master Port is marked “MASTER”. If any
terminal has a priority service mode, ensure it is connected to the port connector
designated “PORT 1” on the rear panel of the MSD. Secure other terminals to be
serviced to the remaining PORT connectors. Connect the MODEM to the connector
designated “MASTER”.

Equipment Grounding (Switch Pos 6)

Position 6 on the DIP switch provides for grounding interconnection in those systems
requiring a connection between (Frame Ground) and (Signal Ground). Connect ONLY
if required.

Anti-Streaming (Switch Pos 1,2,3,4)

The maximum data block size is user selectable via the internal DIP switch positions
1, 2, and 3. As shown below eight block sizes are provided to the user. To disable
anti-streaming set position 4 to 

OFF

OFF

OFF

OFF

OFF

. The maximum block size is normally defined at

the time of installation. The MSD will isolate the affected sub-channel until the
streaming condition has been corrected, then automatically re-establish
communications as before.

3

2

1

Time

OFF

OFF

OFF

.02 sec

OFF

OFF

ON

.04 sec

OFF

ON

OFF

.08 sec

OFF

ON

ON

.30 sec

ON

OFF

OFF

1.3 sec

ON

OFF

ON

5.0 sec

ON

ON

OFF

20.0 sec

ON

ON

ON

40.0 sec

Summary of Contents for 3012/V24, 3014/V24, 3018/V24

Page 1: ...12 A MODEM SHARING DEVICE 3012 V24 CTS MSD 2C 3014 V24 CTS MSD 4C 3018 V24 CTS MSD 8C INSTALLATION AND OPERATIONS MANUAL B AnISO 9001 CertifiedCompany Copyright 2000 Patton Electronics Co All Rights R...

Page 2: ...rt 07M3012 A MODEM SHARING DEVICE 3012 V24 CTS MSD 2C 3014 V24 CTS MSD 4C 3018 V24 CTS MSD 8C INSTALLATION AND OPERATIONS MANUAL B AnISO 9001 CertifiedCompany Copyright 2000 Patton Electronics Co All...

Page 3: ...anty period shall be two years from the date of shipment of equipment Patton s sole obligation under its warranty is limited to the repair or replacement of the defective equipment provided it is retu...

Page 4: ...ion 2 1 Factory Configuration Switch Settings 2 1 Disassembly 2 2 Installation 2 3 Equipment Grounding Switch Pos 6 2 3 Anti Streaming Switch Pos 1 2 3 4 2 3 Switching Mode Selection Switch Pos 5 MSD...

Page 5: ...the attached DCE device on the Master Port The Patton MSDs have Anti Streaming capabilities that include selectable time outs depending on your system transmission speed and a setting to disable anti...

Page 6: ...will automatically default to the highest priority lowest number sub channel with activity Port Enable Disable front panel switches must be pushed in GREEN indication for a sub channel to access the...

Page 7: ...es when AC voltage is applied Two adjacent green LED indicators illuminate in union with individual port activity and identify Transmit Data TXD and Receive Data RXD activity Positive latching type sw...

Page 8: ...on Switch Settings The MSDs are configured prior to shipment with the switches set to the following default positions 3012 V24 CTS MSD 2C Switch 3 positions 4 5 and 6 to OFF OFF OFF OFF OFF 1 2 and 3...

Page 9: ...and 10 Test Voltage JP6 to OUT OUT OUT OUT OUT CTS delay No Delay JP1 JP2 and JP3 to IN IN IN IN IN Factory Test Jumpers must be installed If the system application requires one or more of the default...

Page 10: ...tors Connect the MODEM to the connector designated MASTER Equipment Grounding Switch Pos 6 Position 6 on the DIP switch provides for grounding interconnection in those systems requiring a connection b...

Page 11: ...unit If the terminal will not toggle RTS it will not work with an MSD CTS Delay on the 3012 V24 CTS MDS 2C Switch Pos 5 If a 25 mS CTS delay is desired set switch position 5 to ON ON ON ON ON If no de...

Page 12: ...S channel one has highest access Sub Channel Interface EIA RS 232 V 24 female connectors DB 25 Modem Interface EIA RS 232 V 24 female connector DB 25 Front Panel Indicators Power Send Receive Data Cha...

Page 13: ...16 17 18 19 20 21 22 23 24 25 Shield com mon Transm it Data from DTE R eceive Data from D CE Request to Send from DTE Clear To Send from D CE Data Set Ready from DCE S ignal Ground com mon Data Carrie...

Page 14: ...le ON Disable OFF Signal to Chassis Ground ON OFF 1 2 3 4 5 6 SW3 3012 V24 CTS MSD 2C CTS Delay 25mS ON No Delay OFF JP1 5V JP1 JP2 JP3 JP4 JP5 5V 8V 8V Negative Test Voltage Positive Test Voltage Ant...

Page 15: ...012 14 18 V24 JP1 JP2 JP3 JP4 JP5 5V 8V 8V Negative Test Voltage Positive Test Voltage Anti Stream Timer Anti Stream Enable ON Disable OFF Priority Mode ON Scan Mode OFF Signal to Chassis Ground ON OF...

Page 16: ...B 7622 Rickenbacker Drive Gaithersburg MD 20879 Sales 301 975 1000 Support 301 975 1007 Web Address www patton com...

Reviews: