OnSite 2888 Quick Start Guide

1.0  Powering up the OnSite 

1.1  Connecting the power supply

AC Power

   1.

Connect the AC power cord female plug directly to the OnSite AC connector.

   2.

Connect the AC power cord male plug to an AC power outlet (120–240 VAC).

The 

Power 

LED blinks as the OnSite is powering up. When the 

Power

 LED stops blinking and remains lit, the 

OnSite is ready for user configuration. (See Figure 2 on page 3).

DC Power

The 36-60 VDC DC to DC adapter is supplied with the DC version of the Model 2888.  The black and red leads 
plug into a DC source (nominal 48VDC) and the barrel power connector plugs into the barrel power supply jack 
on the 2888. (See Figure 1 on page 3).

• The OnSite contains no user serviceable parts. The equipment shall be 

returned to Patton Electronics for repairs, or repaired by qualified 
service personnel.

• Mains Voltage: Line voltages are present when the power cord is con-

nected. The mains outlet shall be within 10 feet (3 meters) of the 
device, shall be easily accessible, and protected by a circuit breaker.

• For AC powered units, ensure that the power cable used meets all 

applicable standards for the country in which it is to be installed, and 
that it is connected to a wall outlet which has earth ground.

• Hazardous network voltages are present in WAN ports, regardless of 

whether power to the OnSite is ON or OFF. To avoid electric shock, 
use caution when near WAN ports. When detaching the cables, detach 
the end away from the OnSite first.

• Do not work on the system or connect or disconnect cables during 

periods of lightning activity.

• For units with an external power adapter, the adapter shall be a 

listed Limited Power Source.

The interconnecting cables shall be acceptable for external use and shall be rated for 
the proper application with respect to voltage, current, anticipated temperature, flam-
mability, and mechanical serviceability.

WARNING

CAUTION

Summary of Contents for 2888

Page 1: ...d is intended for use in a light industrial environment It is not intended nor approved for use in an industrial or residential environment Part Number 07M2888 QS Rev B Revised February 23 2012 Sales...

Page 2: ...ltage Line voltages are present when the power cord is con nected The mains outlet shall be within 10 feet 3 meters of the device shall be easily accessible and protected by a circuit breaker For AC p...

Page 3: ...mail at support patton com for more information To Power Supply Jack To 48VDC Source Vin Vin Black lead V Red lead V Barrel power connector SWITCHING POWER SUPPLY MODEL SYD1106 2012 INPUT 36 60V 0 8A...

Page 4: ...ion connect a PC s Ethernet port to the OnSite s LAN port see Figure 3 Use the black Ethernet cable included with your OnSite for this purpose Figure 3 Connecting to the PC s ENET port 2 Configure you...

Page 5: ...4 Log into the unit using the following login admin password 2 4 Changing the IP address To change the OnSite s IP address 1 Login to the unit using admin then use the following set of commands Trini...

Page 6: ...ir cable to the female connector on the OnSite 2 Attach the other end of the cable to the serial connector on the local T1 E1 unit 4 0 Additional information For detailed information about configuring...

Page 7: ...ber states relating to Radio and Telecommunication Terminal Equip ment and the mutual recognition of their conformity The safety advice in the documentation accompanying this product shall be obeyed T...

Page 8: ...t Patton free of charge by using a VoIP ISP phone to call sip support patton com Fax 1 253 663 5693 Alternate Patton support for Europe Middle East and Africa EMEA Telephone support Standard telephone...

Reviews: