4.0  INSTALLATION

After you have configured the DCE/DTE strap, all you need to do

is plug the Model 2020 or 2020N into the proper device ports.  Figures
4 and 5 show how to intstall the Model 2020/2020N.  

*NOTE:  The diagrams below show the Model 2020 in the
installed application.  If you are using a Model 2020N, connect the
RS-232 interface directly to the RS-232 equipment and connect
the V.35 interface to the V.35 interface.

4.1  CONNECTING AN RS-232 DTE TO A V.35 DCE*

Figure 4 (below) illustrates proper connection of an RS-232 DTE

to a V.35 DCE using the Model 2020.  The RS-232 interface of the
Model 2020/2020N must be configured as DCE.

4.2  CONNECTING A V.35 DTE TO AN RS-232 DCE*

Figure 5 (below) illustrates proper connection of a V.35 DTE to

an RS-232 DCE using the Model 2020.  The RS-232 interface of the
Model 2020/2020N must be configured as DTE.

4.3  CONNECTING THE MODEL 2020-25 

The Model 2020-25 is connected the same way as the standard

Model 2020, with the exception that the V.35 interface has a DB-25
connector instead of an M/34 connector.  The DB-25 carries the same
signals as the M/34, but is pinned according to the RS-530 Standard.
Please refer to Appendix B for specific pin out information.

A

AP

PP

PE

EN

ND

DIIX

 

A

A..

MODEL 2020 AND 2020N SPECIFICATIONS

Interfaces

EIA RS-232/ITU/CCITT V.24 to ITU/CCITT 
V.35/EIA RS-530

Data Rates:  

0 - 384 Kbps

Transmission Mode:   Synchronous, full or half duplex

Protocol:  

Transparent to protocol

Clocking:  

Set by connected devices

Connectors:

All Versions: DB-25 male or female on 
RS-232 side; 
Model 2020: M/34 male or female on V.35 
side at the end of 6 ft. cable.
Model 2020-25: DB-25 male or female on 
V.35 side at the end of 6 ft. cable.
Model 2020N: RS-232 Male or Female 
with M/34 male or female on V.35 side.

Power Supply: 

None required.  Uses power from interface 
data and control signals

Temperature Range:

0-60 degrees C (32-140 degrees F)

Altitude:  

0-15,000 feet (0-5,000 meters)

Humidity:  

5 to 95% noncondensing

Dimensions:  

Model 2020:  2.66"L x 2.10"H x 0.73"W
(6.76cmL x 5.33cmH x 1.85cmW)
Model 2020N: 2.40”L x 1.73”H x 0.89”W
(6.10cmL x 4.39cmH x 2.26cmW)

Weight:  

Model 2020:  14 oz, including cable and 
connectors
Model 2020N: 2.2 oz

7

8

Sync. Terminal

(DTE)

V.35 Modem

(DCE)

Figure 4. A Common RS-232 DTE to V.35 DCE Installation

V.35 Mini Computer

(DTE)

Sync. Modem

(DCE)

Figure 5. A common V.35 DTE to RS-232 DCE installation

Summary of Contents for 2020N

Page 1: ...2020 and MODEL 2020N Interface Powered RS 232 to V 35 Converters SALES OFFICE 301 975 1000 TECHNICAL SUPPORT 301 975 1007 http www patton com Part 07M2020 E Doc 077011UE Revised 08 16 99 An ISO 9001...

Page 2: ...les which are designed to provide reasonable protection from such interference in a commercial installation However there is no guaran tee that interference will not occur in a particular installation...

Page 3: ...ser to configure the Model 2020 2020N as DCE to DTE or DTE to DCE In most cases this eliminates the need for special crossover cables Housed in an ultra miniature case measuring only 2 66 x 2 10 x 0 7...

Page 4: ...the Model 2020 2020N s RS 232 port is configured as a DCE and will connect to a RS 232 DTE port The arrow pointing toward the cable at the rear of the PC board shows the orientation of the Model 2020...

Page 5: ...signals as the M 34 but is pinned according to the RS 530 Standard Please refer to Appendix B for specific pin out information A AP PP PE EN ND DI IX X A A MODEL 2020 AND 2020N SPECIFICATIONS Interfac...

Page 6: ...l Timing B Y Transmit Timing A AA Transmit Timing B Signal Ground B Clear To Send D Data Carrier Detect F Receive Data A R Receive Data B T Receive Timing A V Receive Timing B X CCITT V 35 Interface M...

Page 7: ...RC B X RTS CTS C D V 35 RTS CTS 4 5 RS 232 D C D D T R F G F H A V 35 D C D D T R F G 8 20 1 RS 232 5V 5V POWER SUPPLY A N D CTS RTS XC TC 24 15 4 5 D T R D C D D S R 6 8 20 DATA SWITCHING R E G U L...