background image

USER

MANUAL

MODEL 1193RC

G.703/G.704 to Single-mode
Fiber Rack Mount Modem Card

Part# 07M1193RC-A
Doc# 017141UA
Revised 05/04/01

SALES OFFICE
(301)975-1000
TECHNICAL SUPPORT
(301)975-1007
http://www.patton.com

An ISO-9001

Certified

Company

Summary of Contents for 1193RC

Page 1: ...1193RC G 703 G 704 to Single mode Fiber Rack Mount Modem Card Part 07M1193RC A Doc 017141UA Revised 05 04 01 SALES OFFICE 301 975 1000 TECHNICAL SUPPORT 301 975 1007 http www patton com An ISO 9001 C...

Page 2: ...the following lost profits lost savings and incidental or consequen tial damages arising from the use of or inability to use this product Patton Electronics specifically disclaims all other warrantie...

Page 3: ...his product please do not hesitate to con tact Patton Electronics Technical Support at 301 975 1007 2 1 FEATURES ITU G 703 G 704 E1 transport over Single mode fiber Full duplex operation over a single...

Page 4: ...2 Setting Description On On Internal Transmit clock generated internally On Off Receive Recover Transmit clock derived from the Receive data on the fiber side Off On Network Transmit clock derived fro...

Page 5: ...l 1001RCM703SC with SC fiber connector and 1001RCM703FC with FC fiber connector See Figure 4 at upper right Each of these inter face cards support one fiber connector two BNC and one RJ 48C line conne...

Page 6: ...ower card replacement information 4 4 0 0 I IN NS ST TA AL LL LA AT TI IO ON N This section describes the functions of the Model 1001R14 rack chassis tells how to install front and rear Model 1193RC S...

Page 7: ...section describes both options After selecting the appropriate connec tion set the internal jumpers as described in section 3 2 of this manual 4 2 1 Connecting theTwisted Pair 120 Ohm to G 703 G 704 N...

Page 8: ...synchro nization process should take approximately 5 seconds Any time one of the Model 1193RCs lose power i e in a lightning storm the local and remote units will re synchronize before they can resum...

Page 9: ...tern generator See section 5 2 3 on how to use the built in 511 511E pattern generator 3 If the BER test equipment indicates a fault and the Local Analog Loopback test was successful for both Model 11...

Page 10: ...OS LED indicates the presense of coding errors NS The red NS LED indicates that the sig nal on the fiber side is too weak to be detected ER Flashing red ER LED indicates errors in 511 test pattern TM...

Page 11: ...240V Front Power Supply Module 1001RPEM RDC DC Rear Power Entry Module 1001RPSM R48A 48V Front Power Supply Module 1001R14P Rack 14 Slot 2U Chassis Only 1001R14P R48V Rack 14 Slot 2U w Dual Universal...

Reviews: