1.3  SERVICE

All warranty and non-warranty repairs must be returned freight

prepaid and insured to Patton Electronics.  All returns must have a
Return Materials Authorization number on the outside of the shipping
container.  This number may be obtained from Patton Electronics
Technical Support at:

tel:      

(301)975-1007

email:  

[email protected]

www:  

http://www.patton.com

Patton Electronics' technical staff is also available to answer any

questions that might arise concerning the installation or use of your
Model 1186RC.  Technical Support hours:  

8AM to 5PM EST, Monday

through Friday.

3

2.0  GENERAL INFORMATION

2.0  GENERAL INFORMATION

Thank you for your purchase of this Patton Electronics product.  This

product has been thoroughly inspected and tested and is warranted for
one year parts and labor.  If any questions or problems arise during instal-
lation or use of this product, please do not hesitate to contact Patton
Electronics Technical Support at (301) 975-1007.

2.1  FEATURES

·  ITU G.703/G.704 (E1) transport over Multi-Mode fiber
·  Full duplex operation over a single string of fiber
·  Multi-Mode fiber with max distance 2.5km (1.5 miles)
·  Two fiber connection options available: ST or SMA
·  120 Ohm (RJ-48C) and 75 Ohm (dual coax) G.703/G.704 terminations
·  Clocking Options: Internal, Network (G.703/G.704) or Receive

Recover (fiber link)

·  Optional AMI or HDB3 G.703/G.704 data coding
·  Six Front Panel LED status indicators: Fiber line, E1 line, LOS, TM,

ER, and NS

·  Testing/troubleshooting tools: V.54 compliant local/remote loop

backs, V.52 compliant 511/511E test patterns

2.2  DESCRIPTION

The Patton Electronics 

Model 1186RC

offers the ability to extend E1

(G.703/G.704) service over Multi-Mode fiber. A pair of 1186RC Multi-Mode
Fiber Modems provides G.703/G.704 Network "extension" between remote
locations (Figure 1). 

The Model 1186RC is designed to transmit/receive G.703/G.704 data

over one string of fiber. The Model 1186RC allows transmission over Multi-
Mode fiber with distances up to 2.5 km (1.5 miles). The clocking options
for the Model 1186RC include Internal, Network (from G.703/G.704
Network) or Receive Recovered clock (from fiber line). 

The Model 1186RC also incorporates V.54 compliant local/remote

loopbacks and V.52 compliant 511/511E test patterns. Front panel switches
activate test patterns and loopbacks. LED status indicators monitor the
fiber and G.703/G.704 links. The Model 1186RC is supplied with a
1001RCM703ST (with an ST fiber connector) or a 1001RCM703SMA (with
an SMA fiber connector) rear card. 

4

NOTE:  

Packages received without an RMA number will not be

accepted.

Figure 1. 

Network extension remote location

G.703/G.704

G.703/G.704

Fiber Optic Line

Modem

Modem

Summary of Contents for 1186RC

Page 1: ...L 1186RC G 703 G 704 to Multi mode Fiber Rack Mount Modem Card Part 07M1186RC A Doc 017171UA Revised 12 01 00 SALES OFFICE 301 975 1000 TECHNICAL SUPPORT 301 975 1007 http www patton com An ISO 9001 C...

Page 2: ...hese damages include but are not limited to the following lost profits lost savings and incidental or consequen tial damages arising from the use of or inability to use this product Patton Electronics...

Page 3: ...4 terminations Clocking Options Internal Network G 703 G 704 or Receive Recover fiber link Optional AMI or HDB3 G 703 G 704 data coding Six Front Panel LED status indicators Fiber line E1 line LOS TM...

Page 4: ...e 1186RC S1 S2 Setting Description On On Internal Transmit clock generated internally On Off Receive Recover Transmit clock derived from the line Off On Network Transmit clock derived from G 703 G 704...

Page 5: ...with ST fiber connector and 1001RCM703SMA with SMA fiber connector See Figure 4 at upper right Each of these inter face cards support one fiber connector two BNC and one RJ 48C line connectors The in...

Page 6: ...switched on a red front panel LED will glow Since the Model 1001R14 is a hot swappable rack it is not necessary for any cards to be installed before switching on the power supply The power supply may...

Page 7: ...ections The connector pinout and signals are shown in Figure 8 below RX Data FROM G 703 G 704 Network TX Data TO G 703 G 704 Network Network Figure 8 Fiber cable to G 703 G 704 Interface connection Fi...

Page 8: ...ttern gen erator to evaluate the condition of the modems and the communication link These tests can be activated physically from the front panel 5 2 1 Local Loopback The local loopback test checks the...

Page 9: ...front panel switch to the NORMAL position The TM LED should turn off on both local and remote units 5 2 3 V 52 Test Pattern Generator To use the V 52 BER test in conjunction with the Local or Remote...

Page 10: ...s not been established Blinking red LOS LED indicates the presense of coding errors NS The red NS LED indicates that the sig nal on the fiber side is too weak to be detected ER Flashing red ER LED ind...

Page 11: ...nput 48VDC Power Supplies 1001R14P RUIA Rack 14 Slot 2U w Dual Universal Input 90 260VAC Power Supplies European Power Cord 1001R14P RUIC Rack 14 Slot 2U w Dual Universal Input 90 260VAC Power Supplie...

Reviews: