5.3.2. Remote Digital Loopback (RDL)

The Remote Digital Loopback test checks the performance of both

the local and remote Model 1186s, and the communication link
between them. In this test, any characters sent from the originating
device to the remote unit will be returned (see Figure 12). Any data
sent from the remote DTE wil be ignored.

To perform a RDL test, follow these steps:

1. Activate RDL by moving front panel toggle switch DOWN to
"Remote". The TM LED on both local and remote units will light up.  

2. Perform a BER (Bit Error Rate) test on the system, using BER tester
on the local end. BER test can also be performed using built-in
511/511E pattern generator. (See section 5.3.3 on how to use the built-
in 511/511E pattern generator.)

3. If the BER test equipment indicates a fault and the Local Analog
Loopback test was successful for both Model 1186s, there may be a
problem with the line between the units. 

4.  Upon completion of the RDL test, return the front panel switch to
the NORMAL position. The TM LED should turn off on both local and
remote units.

5.3.3. V.52 Test Pattern Generator 

To use the V.52 BER test in conjunction with the Local or Remote
Loopbacks, follow these instructions:

1. Locate the "511/511E" toggle switch on the front panel of the Model
1186 and move it UP. This activates the V.52 BER test mode and
transmits a "511" test pattern into the loop. If any errors are present,
the local modem's red "ER" LED will blink intermittently.

15

2. If the above test indicates no errors, move the V.52 toggle switch
DOWN, activating the "511/E" test with errors present. If the test is
working properly, the local modem's red "ER" LED will blink once every
two seconds. A successful "511/E" test will confirm that the link is in
place, and that the built-in "511" generator and detector are working
properly.

16

Figure 12.

Remote Loopback Diagram

G.703/G.704

Network

Note: When the unit is set for Network Clock Mode, the unit will
derivew its timing from the G.703/G.704 Interface. Failure to connect
to G.703/G.704 may result in bit errors during the 511 or 511/E test.

Summary of Contents for 1186

Page 1: ...Mode Fiber Modem with Fixed G 703 G 704 Interface Part 07M1186 UM Doc 01716U2 001 Rev C Revised 10 25 06 SALES OFFICE 301 975 1000 TECHNICAL SUPPORT 301 975 1007 http www patton com C E R T I F I E D...

Page 2: ...limited to the following lost profits lost savings and incidental or consequen tial damages arising from the use of or inability to use this product Patton Electronics specifically disclaims all other...

Page 3: ...3 G 704 terminations Clocking Options Internal Network G 703 G 704 or Receive Recover fiber link Optional AMI or HDB3 G 703 G 704 data coding Six Front Panel LED status indicators Fiber line E1 line L...

Page 4: ...S2 Setting Description On On Internal Transmit clock generated internally On Off Receive Recover Transmit clock derived from the line Off On Network Transmit clock derived from G 703 G 704 equipment...

Page 5: ...witches S5 through S8 are reserved for future applications and should be set to OFF 3 1 2 Select RJ 48C or BNC Connectors The Model 1193 is shipped configured for use with a BNC connec tion to the G 7...

Page 6: ...75 ohm dual coax G 703 G 704 Network inter face If your G 703 G 704 Network terminates via dual coaxial cable 10 use the diagram below to make the proper connections The connec tor pinout and signals...

Page 7: ...y This section describes power up reading the LED status monitors and using the built in loopback test modes 5 1 POWER UP To apply power to the Model 1186 first be sure that you have read Section 4 3...

Page 8: ...The local loopback test checks the operation of the local Model 1186 and is performed separately on each unit The following section describes how to perform a local loopback test between the Network a...

Page 9: ...e RDL test return the front panel switch to the NORMAL position The TM LED should turn off on both local and remote units 5 3 3 V 52 Test Pattern Generator To use the V 52 BER test in conjunction with...

Page 10: ...errors NS The red NS LED indicates that the sig nal on the fiber side is too weak to be detected ER Flashing red ER LED indicates errors in 511 test pattern TM The yellow TM LED indicates that modem...

Page 11: ...100 240VAC 5V 5 reg DC 2A Universal Input Adapter 0805EUR European Power Cord CEE 7 A 0805UK United Kingdom Power Cord D 0805US American Power Cord K 0805AUS Australia New Zealand Power Cord C 0805DEN...

Reviews: