5.3  TEST MODES

The Model 1140ARC offers two V.54 test modes and two V.52 test

modes to evaluate the condition of the modems and the communication
link.  Both sets of tests can be activated physically from the front panel.
The V.54 test can also be activated from the RS-232 interface.  

Note:

V.54 and V.52 test modes on the Model 1140ARC are available for
point-to-point applications only.

5.3.1  LOCAL ANALOG LOOPBACK (LAL)

The Local Analog Loopback (LAL) test checks the operation of the

local Model 1140ARC, and is 

performed separately on each unit.

Any

data sent to the local Model 1140ARC in this test mode will be echoed
(returned) back to the user device.  For example, characters typed on
the keyboard of a terminal will appear on the terminal screen.  To
perform a LAL test, follow these steps:

1.

Activate LAL.  This may be done in one of two ways:  First, by
moving the upper front panel toggle switch RIGHT to “Analog”.
Second, by raising pin 18 on the RS-232 interface (note: be
sure DIP switch S2-8 is off).  Once LAL is activated, the Model
1140ARC transmit output is connected to its own receiver.
The “Test” LED should be lit.

2.

Verify that the data terminal equipment is operating properly
and can be used for a test.  

3.

Locate the lower of the two toggle switches on the front panel
of the Model 1140ARC and move it to the right.  This will
activate the V.52 BER test mode and inject a “511” test pattern
into the local loop.  If any errors are present in the loop, the
red “Error” LED will blink sporadically.

4.

If the BER test indicates 

no errors

are present,  move the V.52

toggle switch to the left, thus activating the “511/E” test with
periodic errors.  If the test is working properly, the red “Error”
LED will light.  A successful “511/E” test will confirm that the
loop is in place, and that the Model 1140ARC’s built-in “511”
generator and detector are working properly.

5.

If the BER test indicates that errors 

are

present, check to see

that the RS-232 cable connecting the DTE to the Model
1140ARC is wired straight through, and is plugged in properly.
Also, ensure that the Model 1140ARC is configured properly.
Then re-check your DTE equipment.  If you still have errors,
call 

Patton Technical Support at (301) 975-1007.

16

5.3.2  REMOTE DIGITAL LOOPBACK (RDL)

The Remote Digital Loopback (RDL) test checks the performance of

both the local and remote Model 1140ARCs, 

and

the communication

link between them.  Any characters sent to the remote 1140ARC in this
test mode will be returned back to the originating device.  For example,
characters typed on the keyboard of the local terminal will appear on
the local terminal screen 

after

having been passed to the remote Model

1140ARC and looped back.  To perform an RDL test, follow these
steps:

1.

Activate RDL.  This may be done in two ways:  First, by
moving the upper front panel toggle switch LEFT to “Remote”.
Second, by raising pin 21 on the RS-232 interface.  (Note: be
sure DIP switch S2-8 is off).

2.

Verify that the DTE equipment on the local end is operating
properly and can be used for a test.

3.  Locate the lower of the two toggle switches on the front panel

of the 1140ARC and move it to the right.  This will activate the
V.52 BER test mode and inject a “511” test pattern into the
remote loop.  If any errors are present in the loop, the red
“Error” LED will blink sporadically.

4.

If the BER test indicates 

no errors

are present,  move the V.52

toggle switch to the left, thus activating the “511/E” test with
periodic errors.  If the test is working properly, the red “Error”
LED will light.  A successful “511/E” test will confirm that the
loop is in place, and that the Model 1140ARC’s built-in “511”
generator and detector are working properly.

5.

If the remote BER test indicates that errors 

are

present, and

the local analog loopback/BER tests showed that both Model
1140ARCs were functioning properly, this suggests a problem
with the twisted pair communication line connecting the two
modems.  A common problem is improper crossing of the
pairs.  Also, verify that the modular connections are pinned
properly, and the twisted pair line has continuity.  If you still
have errors, call 

Technical Support at (301) 975-1007.

Summary of Contents for 1140ARC

Page 1: ...2 Fiber Optic Rack Card Modem w V 54 V 52 Diagnostics SALES OFFICE 301 975 1000 TECHNICAL SUPPORT 301 975 1007 http www patton com Part 07M1140ARC A Doc 018032U Rev B Revised 1 22 08 C E R T I F I E D...

Page 2: ......

Page 3: ...tainer This number may be obtained from Patton Electronics Technical Support 301 975 1007 http www patton com or support patton com NOTE Packages received without an RMA number will not be accepted Pa...

Page 4: ......

Page 5: ...le when the cards are removed from the rack chassis Once configured the Model 1140ARC is designed to operate transparently without need for frequent re configuration 3 1 FRONT CARD CONFIGURATION The M...

Page 6: ......

Page 7: ...Synchronous Mode The setting for switch S1 7 determines whether the Model 1140ARC is in asynchronous or synchronous operating mode S1 7 Setting On Asynchronous Off Synchronous S1 8 Carrier Control Met...

Page 8: ......

Page 9: ...V 54 circuit set switch S2 6 to the ON position then back to the OFF position S2 8 Setting Off V 54 Enable On V 54 Disable 3 2 REAR CARD CONFIGURATION The Model 1140ARC is compatible with two dual fi...

Page 10: ......

Page 11: ...K POWER SUPPLY The power supply included in the Model 1000R16 rack uses the same mid plane architecture as the modem cards The front card of the power supply slides in from the front and the rear card...

Page 12: ......

Page 13: ...out is the same as a standard DB 25 Pin 26 is not used You will need an interface cable to connect the Model 1140ARC to your RS 232 device Assuming your RS 232 device is a DTE PC host terminal worksta...

Page 14: ......

Page 15: ...ol signal is off When the 1140ARC is connected to a DTE RTS will glow green for an incoming signal on RS 232 pin 4 CD will glow green for an incoming signal from the line and an outgoing signal on RS...

Page 16: ......

Page 17: ...on the front panel of the 1140ARC and move it to the right This will activate the V 52 BER test mode and inject a 511 test pattern into the remote loop If any errors are present in the loop the red Er...

Page 18: ......

Page 19: ...CTS Delay Switch selectable No delay 7 0 mS 53 mS Receiver Sensitivity 45 dBm Coupled Power Output 20 to 25 dBm Optic Wavelength 850 nm LED Indicators Power TD RD RTS CD Test Mode Error Connectors HD...

Page 20: ......

Page 21: ...Signal Ground 6 DSR Data Set Ready 5 CTS Clear to Send 4 RTS Request to Send 3 RD Receive Data 2 TD Transmit Data 1 FG Frame Ground UNIVERSAL D 26 INTERFACE DCE WIRING Digital Loop RDL 21 Data Termina...

Page 22: ......

Page 23: ...________________ __________________________________________ __________________________________________ __________________________________________ __________________________________________ ___________...

Page 24: ......

Reviews: