Patton electronics 1140 User Manual Download Page 7

1.  Locate the “511/511E” toggle switch on the front panel of the

1140 and move it DOWN.  This activates the V.52 BER test mode and
transmits a “511” test pattern to the other unit.  If any errors are pres-
ent, the receiving modem’s red “Error” LED will blink sporadically.
Note:  For this test to function, the “511” switch on both Model 1140s
must be on.

2.  If the test indicates no errors are present, move the V.52 toggle

switch UP, activating the “511/E” test with errors present.  If the test is
working properly, the receiving modem's red “Error” LED will glow.  A
successful “511/E” test will confirm that the link is in place, and that the
Model 1140’s built-in “511” generator and detector are working proper-
ly.

5.3  POWER UP

Once the Model 1140 is properly installed, it should operate trans-

parently—as if it were a standard cable connection.  Since operating
power is derived from the RS-232 data and control signals; there is no
“ON/OFF” switch.  All data signals from the RS-232 interface are
passed straight through. 

APPENDIX A

SPECIFICATIONS

Transmission Line:  Dual optical cable

Transmission Mode:  Async. or sync., half or full duplex

Interfaces: EIA RS-232, CCITT V.24

Data Rates:  0 - 38.4 Kbps

Distance: 2 miles over continuous fiber

RTS/CTS Delay:  Switch-selectable:  No delay, 9.0 mS, 79.5 mS

Receiver Sensitivity:  -45 dBm

Coupled Power Output:  -30 to -36 dBm

Optic Wavelength:  850 nm

LED Indicators:  Carrier Detect and Fiber Optic Output

Connectors:  DB-25 male or female on RS-232 side; ST or SMA con-

nectors on fiber side

Power Supply:  No external power required; uses power from RS-232

data and control signals

Temperature Range:  0-60°C (32-140°F)

Altitude:  0-15,000 feet

Humidity:  Up to 95% non-condensing

Weight:  2 oz.

Dimensions:  23.42” x 2.10” x 0.73”

11

12

Summary of Contents for 1140

Page 1: ...USER MANUA L MODEL 1140 Miniature Fiber Optic Modem w V 54 Diagnostics SALES OFFICE 301 975 1000 TECHNICAL SUPPORT 301 975 1007 http www patton com Part 07M1140 A Doc 018041UA Revised 9 21 94...

Page 2: ...ll returns must have a Return Materials Authorization number on the outside of the shipping container This number may be obtained from Patton Electronics Technical Service at 301 975 1007 Packages rec...

Page 3: ...d signaling rates async or sync mode The drawings text and tables on the following pages describe all switch locations positions and functions The Model 1140 has two sets of eight switches yielding 16...

Page 4: ...us or synchronous operating mode S1 7 Setting On Asynchronous Off Synchronous S1 8 Carrier Control Method The setting for switch S1 8 determines whether the carrier is con stantly on or controlled by...

Page 5: ...tch S2 6 to the ON position then back to the OFF position S2 8 Setting Off V 54 Enable On V 54 Disable 4 0 INSTALLATION The Model 1140 is easy to install After configuring the DIP switches simply conn...

Page 6: ...erform a BER bit error rate test on each unit If the BER test equipment indicates no faults but the data terminal indicates a fault follow the manufacturer s checkout procedures for the data termi nal...

Page 7: ...operate trans parently as if it were a standard cable connection Since operating power is derived from the RS 232 data and control signals there is no ON OFF switch All data signals from the RS 232 in...

Page 8: ...RD Receive Data From Model 1140 4 RTS Request to Send To Model 1140 5 CTS Clear to Send From Model 1140 6 DSR Data Set Ready From Model 1140 7 SG Signal Ground 8 DCD Data Carrier Detect From Model 114...

Reviews: