been placed in Test Mode.  The unit can be placed in 
test mode by the local or remote user.

NS

Glow red to indicate that the local Model 1092A has 
not yet connected with the remote 

5.3  TEST MODES

The Model 1092A offers two proprietary loopback test modes, plus

a built-in V.52 BER test pattern generator, to evaluate the condition of
the modems and the communication link.  These tests can be activated
physically from the front panel, or via the interface.  

5.3.1  Local Line Loopback (LLB)

The Local Line Loopback (LLB) test checks the operation of the

local Model 1092A, and is performed separately on each unit.  Any data
sent to the local Model 1092A in this test mode will be echoed
(returned) back to the user device (see Figure 7, below).  For example,
characters typed on the keyboard of a terminal will appear on the

terminal screen.

To perform an LLB test, follow these steps:
1.

Activate LLB.  This may be done in one of three ways:  
-  Move the front panel toggle switch to the right to 

“Local”.  

-  Raise the LLB signal on the interface (see Appendix C).  
-  Set Local Loop from the VT100 screen.

Once LLB is activated, the Model 1092A transmitter output is

connected to its own receiver. Data is also looped back to the line.  The
“TM” LED should be lit. 

2.

Verify that the data terminal equipment is operating 
properly 

and can be used for a test.  

3.  

Perform a V.52 BER (bit error rate) test as described in 

Section 5.3.3

.  If the BER test equipment indicates no faults, 

but the data terminal indicates a fault, follow the 

manufacturer’s checkout procedures for the data terminal.  Also,

check the interface 

cable between the terminal and the Model 1092A.

Figure 7. Local Line Loopback

LLB initiated

27

5.3.2  Remote Digital Loopback (RDL)

The Remote Digital Loopback (RDL) test checks the performance

of both the local and remote Model 1092As, and the communication
link between them.  Any characters sent to the remote Model 1092A in
this test mode will be returned back to the originating device (see
Figure 8, below).  For example, characters typed on the keyboard of the
local terminal will appear on the local terminal screen after having been
passed to the remote Model 1092A and looped back. 

To perform an RDL test, follow these steps:

1.

Activate RDL.  This may be done in three ways:  

-  Move the front panel toggle switch to the Left to “Remote”.  
-  Raise the RDL signal on the interface (see Appendix C).
-  Set Remote Loopback from the VT100 screen.

2.

Perform a V.52 BER test as described in 

Section 5.3.3

.  If the 

BER test equipment indicates a fault, and the Local Line 
Loopback test was successful for both Model 1092As, you 
may have a problem with the twisted pair line between the 
modems. You should then check the twisted pair line for 
proper connections and continuity.

28

Figure 8.  

Remote Digital Loop

Local 1092A

Remote 1092A

RDL initiated

Important! Do not send a 511 test pattern from the test
equipment when you connect external test equipment to the
1092A .

Note: Remote Loopback cannot be activated until
approximately 45 seconds after the two modems have
linked to each other.

Summary of Contents for 1092A

Page 1: ...DEL 1092A High Speed 2 Wire 4 Wire Sync Async Short Range Modem Part 07M1092A E Doc 033031UD Revised 03 29 00 SALES OFFICE 301 975 1000 TECHNICAL SUPPORT 301 975 1007 http www patton com An ISO 9001 Certified Company ...

Page 2: ...condition shall Patton Electronics be liable for any damages incurred by the use of this product These damages include but are not limited to the following lost profits lost savings and incidental or consequential damages arising from the use of or inability to use this product Patton Electronics specifically disclaims all other warranties expressed or implied and the installation or use of this p...

Page 3: ...twisted pair 2 or 4 Wires Point to point distances up to 11 miles 17 6Km Remote digital loopback local line loopback diagnostics Internal external or receive recovered clocking options LED indicators for TD RD CTS CD DTR TM ER and NS Standard Gas Tube Surge Protection Made in the U S A 2 2 DESCRIPTION The Patton Electronics Model 1092A KiloModem 2W 4WTM baseband modem allows synchronous or asynchr...

Page 4: ...f eight DIP switches which allow configuration of the unit to a wide variety of applications This section describes switch locations and explains all possible configurations 3 1 CONFIGURING THE HARDWARE DIP SWITCHES The Model 1092A uses a unique set of 16 external mini DIP switches that allow configuration to a wide range of applications The 16 external switches are grouped into two eight switch s...

Page 5: ...n Reserved Reserved On Off On Reserved Reserved Off Off On 19 2 kbps Reserved Possible Bit Rate Settings Switch S1 1 S1 2 and S2 1 8 Switch S1 3 Data Set Ready During Line Loopback Test Use Switch S1 3 to control the behavior of the DSR signal at the EIA interface during the line loopback test S 3 Setting On DSR is on during local line loop Off DSR is off during local line loop Switches S1 4 Manag...

Page 6: ...2 SUMMARY TABLE Position Function Factory Default S2 1 Data Rate Off S2 2 Front Panel Switch Enable Off Enable S2 3 Response to LAL from DTE Off Disabled S2 4 2 Wire 4 Wire Off 2 Wire S2 5 Not Assigned Off S2 6 Response to RDL from DTE On Enabled S2 7 Not Assigned Off S2 8 Not Assigned Off 10 Switch S2 3 Response to Local Line Loop Requests from DTE Use Switch S2 3 to enable Local Line Loopback co...

Page 7: ...wered on the control port will send out this message Model 1092A Software version x xx Patton Electronics Copyright C 2000 5 Press ESC on the terminal 6 The 1092A will then display the MAIN MENU screen You may configure the LOCAL Model 1092A from this screen Important To make a selection from any menu enter the option number To exit any menu without making a selection or to return to the previous ...

Page 8: ...inally select MAIN MENU Option 8 to save the changes SOFTWARE 14 MAIN MENU Option 4 Setup Software Configuration Select Option 4 to edit the software configuration of the Model 1092A To save changes after editing the software configuration select MAIN MENU Option 5 then select Use Software Switches and then select MAIN MENU Option 8 1 DTE Rate Select Option 1 in the SOFTWARE CONFIGURATION menu to ...

Page 9: ...ster Clock either internal or external and the other must be Slaved to the Receive Clock 16 4 DSR During Local Line Loop Select Option 4 in the SOFTWARE CONFIGURATION to configure the behavior of the local Data Set Ready DSR signal during the Local Line Loop test mode below 5 Response to Remote Digital Loop Select Option 5 in the SOFTWARE CONFIGURATION Menu to instruct the Model 1092A to either re...

Page 10: ...on 1 4 Wire Mode 2 2 Wire Mode MAIN MENU Option 6 Display Modem Status Select Option 6 from MAIN MENU to display the Modem Status below Press the space bar on the keyboard to update and redisplay the screen NOTE Valid Model 1092A Handshake Statuses are listed below 1 Handshaking This status occurs when the 1092A is in the process of establishing a link with another 1092A 2 Data Mode This status oc...

Page 11: ... Menu Press the space bar to update and redisplay the status 20 4 0 INSTALLATION Once the Model 1092A is properly configured it is ready to connect to the twisted pair interface to the serial port and to the power source This section tells you how to make these connections 4 1 CONNECTING THE TWISTED PAIR INTERFACE The Model 1092A supports communication between two DTE devices at distances to 5 mil...

Page 12: ...particular version of the Model 1092A it should be shipped to you with the appropriate QuikConnect Module already installed If you need to install a different QuikConnect Module follow these steps Removing the Existing QuikConnect Module 1 Turn the power switch off Leave the power cord plugged into a grounded outlet to keep the unit grounded 2 Loosen the two thumbscrews on the module by turning th...

Page 13: ...Pin out requirements for null modem applications vary widely between manufacturers If you have any questions about a specific application contact Patton Electronics Technical Support 24 4 2 4 Configuring the X 21 QuikConnect Module The serial port on the X 21 QuikConnect Module is default wired as a DCE but may be switched to a DTE This is done by reversing the orientation of the DCE DTE strap as ...

Page 14: ...er switch 5 2 LED STATUS MONITORS The Model 1092A features eight front panel LEDs that monitor power the DTE signals network connection and test modes Figure 6 below shows the front panel location of each LED Following Figure 6 is a description of each LEDs function TD RD Glows yellow to indicate an idle condition of Binary 1 data on the respective terminal interface signals Green indicates Binary...

Page 15: ...t indicates no faults but the data terminal indicates a fault follow the manufacturer s checkout procedures for the data terminal Also check the interface cable between the terminal and the Model 1092A Figure 7 Local Line Loopback LLB initiated 27 5 3 2 Remote Digital Loopback RDL The Remote Digital Loopback RDL test checks the performance of both the local and remote Model 1092As and the communic...

Page 16: ...ir Clocking Internal external or receive loopback Interface Modules EIA RS 232 ITU T V 24 RS 232 530 ITU T V 35 ITU T X 21 64k G 703 10BaseT Ethernet and Voice Data Data Rates Synchronous 19 2 32 56 64 128 kbps Asynchronous0 38 4 kbps Diagnostics V 52 compliant bit error rate pattern 511 511E pattern generator and detector with error injection mode Local Line Loopback and Remote Digital Loopback a...

Page 17: ...srael Power Cord 0805JAP Japan Power Cord 0805SW Switzerland Power Cord 31 APPENDIX C PATTON ELECTRONICS MODEL 1092A INTERFACE PIN ASSIGNMENT RS 232 RS 530 Interface Pin Description DB 25 Female Connector DCE Configuration Pin Signal 1 FG Frame Ground 2 TD Transmit Data 3 RD Receive Data 4 RTS Request to Send 5 CTS Clear to Send 6 DSR Data Set Ready 7 SGND Signal Ground 8 CD Carrier Detect 9 RC Re...

Page 18: ...a B T RD Receive Data B U XTC External Transmit Clock V RC Receive Timing W XTC External Transmit Clock X RC Receive Timing Y TC Transmit Timing A AA TC Transmit Timing B 34 APPENDIX C PATTON ELECTRONICS MODEL 1092A INTERFACE PIN ASSIGNMENT Continued X 21 Interface DB 15 Female Connector DTE DCE Configuration Pin Signal 1 Frame Ground 2 T Transmit Data A 3 C Control A 4 R Receive Data A 5 I Indica...

Page 19: ...ster the other unit as Slave MASTER UNIT SETTINGS S1 1 ON S1 2 OFF S1 3 ON S1 4 and 5 OFF S1 6 and 7 ON S1 8 ON S2 1 2 and 3 OFF S2 4 ON 4 wire operation OFF 2 wire operation S2 5 OFF S2 6 7 and 8 ON SLAVE UNIT SETTINGS S1 1 ON S1 2 OFF S1 3 ON S1 4 and 5 OFF S1 6 ON S1 7 OFF S1 8 ON Switch S2 settings are the same as the MASTER UNIT 3 Connect the twisted pair circuit between the model 1092A s tur...

Reviews: