Patton electronics 1092 User Manual Download Page 9

Switches S1-4 and S1-5:  Asynchronous/Sync Operation

Use Switches S1-4 and S1-5 to configure the Model 1092 for

async/sync operation. Both switches must be set in the “Off” position.
There is no other valid setting.

S1-4

S1-5

Setting

Off

Off

Async/Sync

On

Off

Reserved

Off On

Reserved

On

On

Reserved

Switches S1-6 and S1-7: System Clock Mode

Use Switches S1-6 and S1-7 to configure the 1092 for internal,

external, or receive recover clock mode.

S1-6

S1-7

Clock Mode

Description

On

On

Internal System 

clock 

generated internally

Off

On

External (DTE)

System clock derived
from terminal interface

On

Off

Receive Recover

System clock derived
from the received line
signal.

Off

Off

Hardware Reset

Switch S1-8:  Response to RDL Request

Use Switch S1-8 to allow Model 1092 to enter the Remote Digital

Loopback diagnostic test when requested to do so by the far end Model
1092  For example, when Switch S1-8 is set to “ON”, it will enter RDL
mode (See Section 5.3.2) when requested to do so by the remote
Model 1092.

S1-8

Setting

On

Response to RDL Request Enabled

Off

Response to RDL Request Disabled

7

3.1.2  Configuration Switch Set “S2”

Use the eight DIP Switches in Switch S2 to enable 19.2 kbps

synchronous operation, set the loopback modes and the speed of the
control port.   The following table summarizes default positions of DIP
Switch S2.  Detailed descriptions of each switch follow the table.

Switches S2-1:  19.2 kbps Synchronous Rate Enable

Use Switch S2-1 to allow the Model 1092 to operate at the 19.2

kbps

synchronous

data rate. 

S2-1

Activation

Description

Off

Disabled

Synchronous data rate is 32 - 128 
kbps as defined by switches S1-1 
and S1-2 

On

Enabled

Model 1092 operates at 
synchronous 19.2 kbps data rate*

*NOTE:

To operate at 19.2 kbps, Set Switches S1-1 and S1-2 to

the OFF position (see page 6, Switches S1-1 and S1-2)

.

Switch S2-2:  Not Assigned

8

S2 SUMMARY TABLE

Position

Function

Factory Default

S2-1

19.2 kbps Enable

Off

S2-2

Not Assigned

Off 

S2-3

Response to LAL from DTE

Off

Disabled

S2-4

Not Assigned

Off

S2-5

Not Assigned

Off

S2-6

Response to RDL from DTE

On

Enabled

S2-7

Control Port Data Rate

On

S2-8

Control Port Data Rate

On

}

9600 bpsc

Important:

A pair of Model 1092s communicate synchronously

across the twisted pair line connection.  Therefore, 

you must set

these switches whether your application is async or sync

.

For X.21 or Async applications, please configure one Model 1092
for internal clock mode and the other Model 1092 for receive
recover clock mode.

Summary of Contents for 1092

Page 1: ...L MODEL 1092 High Speed 2 Wire Sync Async Short Range Modem SALES OFFICE 301 975 1000 TECHNICAL SUPPORT 301 975 1007 http www patton com Part 07M1092 F Doc 033011U Rev G Revised 1 23 08 5 7 Q 62 HUWLI...

Page 2: ......

Page 3: ...led and used properly that is in strict accordance with the manufacturer s instructions may cause interference to radio and television reception The Model 1092 has been tested and found to comply with...

Page 4: ......

Page 5: ...r receive recovered clocking options LED indicators for TD RD CTS CD DTR TM ER and NS Made in the U S A 2 2 DESCRIPTION The Patton Model 1092 is a high speed AC powered short range modem that is able...

Page 6: ......

Page 7: ...s NOTE The Model 1092 can also operate at the 19 2 kbps synchronous rate To operate at 19 2 synchronous set Switches S1 1 and S1 2 both to the OFF position and Switch S2 1 to the ON position see Secti...

Page 8: ......

Page 9: ...a rate S2 1 Activation Description Off Disabled Synchronous data rate is 32 128 kbps as defined by switches S1 1 and S1 2 On Enabled Model 1092 operates at synchronous 19 2 kbps data rate NOTE To oper...

Page 10: ......

Page 11: ...wer up the terminal and set its RS 232 port as follows 9600 Baud 8 data bits i stop bit no parity Local echo CR CR LF on inbound data ANSI VT 100 emulation 3 Verify that switches S2 8 and S2 7 are set...

Page 12: ......

Page 13: ...ware Configuration Select Option 3 to display the configuration of the software switches To use the software configuration for the Active Configuration select MAIN MENU Option 5 Then select Use Softwa...

Page 14: ......

Page 15: ...e the system clock from the locally connected DTE Slaved to Receive Clock Selection 3 to allows the Model 1092 to derive the timing source from the incoming data stream from the remote Model 1092 4 DS...

Page 16: ......

Page 17: ...tion After changing this setting select MAIN MENU Option 8 to implement the changes MAIN MENU Option 6 Display Modem Status Select Option 6 from MAIN MENU to display the Modem Status below Press RETUR...

Page 18: ......

Page 19: ...starts the internal 511 generator and detectors Remote Digital Initiates the Remote Digital Loopback test Loop and and starts the 511test patterns In this test 511 with errors the 511 pattern generato...

Page 20: ......

Page 21: ...splay the status of the REMOTE unit REMOTE MAIN MENU Option 4 Display Hardware Software Control Select REMOTE MAIN MENU Option 4 to select whether the remote Model 1092 will use the hardware switch se...

Page 22: ......

Page 23: ...to you with the appropriate QuikConnect Module already installed If you need to install a different QuikConnect Module follow these steps Removing the Existing QuikConnect Module 1 Turn the power swi...

Page 24: ......

Page 25: ...ion 4 2 1 4 3 POWER CONNECTION The Model 1092 is available with three power supply options Standard AC Power Supply option Model 1092 no suffix is switchable between 100 and 253 VAC and is available w...

Page 26: ......

Page 27: ...1 data on the respective terminal interface signals Green indicates Binary 0 data CTS Glows green to indicate that the Clear to Send signal from the modem is active CD Glows red if no carrier signal...

Page 28: ......

Page 29: ...ce NOTE Switch S1 8 Response to RDL Request on the remote Model 1092 must be enabled 2 Perform a V 52 BER test as described in Section 5 3 3 If the BER test equipment indicates a fault and the Local L...

Page 30: ......

Page 31: ...gnostics V 52 compliant bit error rate pattern 511 511E pattern generator and detector with error injection mode Local Line Loopback and Remote Digital Loopback activated by front panel switch or via...

Page 32: ......

Page 33: ...ta Set Ready 7 SGND Signal Ground 8 CD Carrier Detect 9 RC Receive Timing B 10 CD Carrier Detect B 11 XTC External Transmit Clock 12 TC Test Control B 13 CTS Clear to Send 14 TD Transmit Data B 15 TC...

Page 34: ......

Page 35: ...TE DCE Configuration Pin Signal 1 Frame Ground 2 T Transmit Data A 3 C Control A 4 R Receive Data A 5 I Indication A 6 S Signal Element iming A 7 BT Byte Timing A 8 SGND Signal Ground 9 T Transmit Dat...

Page 36: ......

Page 37: ......

Page 38: ......

Page 39: ......

Page 40: ......

Reviews: