background image

11

4.2.2 Configuration DIP Switch Set “S3” 

Use the DIP Switches in Switch S3 to set the DTE Rate (for LAN

Bandwidth Allocation), the transmit data sampling point and to reset
the unit to its software default settings.   The following table summa-
rizes default positions of DIP Switch S3.  Detailed descriptions of each
switch follow the table.  

Switch S3-1 through S3-6:  DTE Rate

Use Switch S3-1 through S3-6 to provision bandwidth to the LAN

in 64kbps increments up to 2.304Mbps.  Peak bandwidth utilization on
the local domain on an Ethernet LAN runs typically between 15% to
20% (1.5Mbps to 2Mbps) of the maximum bit rate of 10Mbps.  Traffic
between LANs typically runs even lower -- between 2% to 7%
(200kbps to 700kbps) of the maximum bit rate depending upon appli-
cation and environmental conditions.  This is the amount of traffic that
will run across the DSL span.  

Set Switches 3-1 through S3-6 to allocate bandwidth based upon

expected LAN to LAN traffic rates.  As an example, set applications
which low LAN to LAN bandwidth content between 64kbps and
576kbps.  Applications with high bandwidth LAN to LAN content should
be set between 576kbps and 2.304Mbps as required.  

S3-1

S3-2

S3-3

S3-4 S3-5 S3-6

DTE Rate (kbps)

Off

Off

On

On

On

On

64

On

On

Off

On

On

On

128

Off

On

Off

On

On

On

192

On

Off

Off

On

On

On

256

Off

Off

Off

On

On

On

320

On

On

On

Off

On

On

384

Off

On

On

Off

On

On

448

On

Off

On

Off

On

On

512

12

Off

Off

On

Off

On

On

576

On

On

Off

Off

On

On

640

Off

On

Off

Off

On

On

704

On

Off

Off

Off

On

On

768

Off

Off

Off

Off

On

On

832

On

On

On

On

Off

On

896

Off

On

On

On

Off

On

960

On

Off

On

On

Off

On

1024

Off

Off

On

On

Off

On

1088

On

On

Off

On

Off

On

1152

Off

On

Off

On

Off

On

1216

On

Off

Off

On

Off

On

1280

Off

Off

Off

On

Off

On

1344

On

On

On

Off

Off

On

1408

Off

On

On

Off

Off

On

1472

On

Off

On

Off

Off

On

1536

On

On

Off

Off

Off

On

1600

Off

On

Off

Off

Off

On

1664

On

Off

Off

Off

Off

On

1728

Off

Off

Off

Off

Off

On

1792

On

On

On

On

On

Off

1856

Off

On

On

On

On

Off

1920

On

Off

On

On

On

Off

1984

Off

Off

On

On

On

Off

2048

On

On

Off

On

On

Off

2112

Off

On

Off

On

On

Off

2176

On

Off

Off

On

On

Off

2240

Off

Off

Off

On

On

Off

2304

Switch S3-7: Reset Software Defaults

Use Switch S3-7 to reset the software configured factory defaults.

This feature is applicable only using the Model 1001MC to SNMP
through Model 1095 central office to manage your units.  For more
information, please refer to the Model 1001MC Operations Manual.

S3-7

Setting

On

Normal Operation

Off

Reset

Switch S3-8: Reserved

Switch S3-8 is reserved for factory use and must remain in the On

position.  

NOTE:  

The Model 1088 will automatically select the optimum

line rate for the required distance based on the DTE rate set by
Switches S3-1 through S3-6.  This selection is based on the low-
est line rate that will support the DTE rate.

S3 SUMMARY TABLE

Position

Function

Factory Default

S3-1

DTE Rate

On

S3-2

DTE Rate

Off 

S3-3

DTE Rate

Off

S3-4

DTE Rate

Off

S3-5

DTE Rate

On

S3-6

DTE Rate

On

S3-7

Reset Software Defaults

On

Normal Operation

S3-8

Reserved 

On

}

768 kbps

Summary of Contents for 1088/I

Page 1: ...R MANUAL MODEL 1088 I 10BaseT mDSL Rocket Part 07M1088I UM Doc 03311U2 001 Rev D Revised 10 24 06 SALES OFFICE 301 975 1000 TECHNICAL SUPPORT 301 975 1007 http www patton com An ISO 9001 Certified Company ...

Page 2: ...lost profits lost savings and incidental or consequen tial damages arising from the use of or inability to use this product Patton Electronics specifically disclaims all other warranties expressed or implied and the installation or use of this product shall be deemed an acceptance of these terms by the user 1 1 RADIO AND TV INTERFERENCE The Model 1088 generates and uses radio frequency energy and ...

Page 3: ...ivity over 2 Wire mDSL up to 10km NetLink Plug and Play Slave HTTP SNMP Manageable as CP Customer Premises Unit with 1095RC CO Central Office Rack Card Internal or receive recovered clocking between units LED indicators for 10BaseT Link DSL Link Status No Signal Error and Test Mode 2 2 DESCRIPTION The NetLinkTM 10BaseT mDSL Rocket Model 1088 is a Multi Rate DSL Modem that provides seamless MAC Lay...

Page 4: ... 1 shows a typical Cisco router with a serial interface configured as a PPP Half Bridge The router serial interface uses a remote device that supports PPP bridging to function as a node on the remote Ethernet network The serial interface on the Cisco will have an IP address on the same Ethernet subnet as the bridge For example the customer site is assigned the addresses 192 168 1 0 24 through 192 ...

Page 5: ...plication 2 Set the Model 1088 CP to NetLink Plug and Play CP by setting all S2 and S3 DIP switches in the OFF position as described in Figure 3 below When the CO and CP units connect over DSL the CP will enter a predefined default configuration Receive Recovered Clocking During the negotiation process between the units the CO unit will configure the DTE rate line rate on the CP unit as defined by...

Page 6: ... are reserved for fac tory use and must remain in the factory default settings as shown in the table above Switches S2 6 and S2 7 Clock Mode Use Switches S2 6 and S2 7 to configure internal or receive recover clocking derived from the remote Model 1088 across the DSL span settings One Model 1088 typically the CO or Central Office unit will be set for Internal Clock The remote Model 1088 typically ...

Page 7: ...ff On On 576 On On Off Off On On 640 Off On Off Off On On 704 On Off Off Off On On 768 Off Off Off Off On On 832 On On On On Off On 896 Off On On On Off On 960 On Off On On Off On 1024 Off Off On On Off On 1088 On On Off On Off On 1152 Off On Off On Off On 1216 On Off Off On Off On 1280 Off Off Off On Off On 1344 On On On Off Off On 1408 Off On On Off Off On 1472 On Off On Off Off On 1536 On On Of...

Page 8: ...signal pin relationships are shown in Figure 6 below 5 2 CONNECTING 10BASE T ETHERNET PORT TO PC DTE The 10Base T interface is configured as DTE Data Terminal Equipment If the Model 1088 is to to connect to another DTE device such as a 10Base T network interface card construct a 10Base T crossover cable and connect the wires as shown in the diagram below 10BaseT Port 10Base T DTE RJ 45 Pin No RJ 4...

Page 9: ...5 4 and ensure that the unit is connected to the appropriate power source 6 2 LED STATUS MONITORS The Model 1088 features six front panel LEDs that monitor con nections on the DSL and 10BaseT links signaling error and test modes Figure 9 below shows the front panel location of each LED Descriptions of each LED follow Figure 9 DSL Link Active Green Solid green On indicates that the end to end DSL F...

Page 10: ...on is detected 17 6 4 TEST MODES The Model 1088 offers a proprietary Remote Loopback test modes plus a built in V 52 BER test pattern generator to evaluate the communi cation status between units Activate this test mode by toggling the Test Mode Switch on the front panel of the unit 6 4 1 Overview Figure 10 below shows the major elements used in the loop back and 511 pattern tests available in the...

Page 11: ...ns The following section describes the Remote Loopback BER test modes Remote Digital When Remote Loop 511 or Remote Loop 511 E is enabled via the front panel switch the Remote unit s Restart Timer is set to one minute This is because when the 511 511E gen erator is initiated on the local unit the Remote framer begins seeing unframed packets The Remote unit can not distinguish the 511 511E pattern ...

Page 12: ...Connection Status Flashing Yellow Status indica tion from the Ethernet port NS Red Active No signal on DSP Link ER Flashing Red CRC error during nor mal operation bit error during pattern gen eration test TM Active Yellow Test Mode Enabled Configuration Externally accessible dip switches or SNMP HTTP managed through 1095RC Power 5V External desk top power supply 100 240VAC 50 60 Hz Universal Input...

Page 13: ...70380 13 3 21 7 90488 17 1 27 8 400 320 384 18600 3 5 5 7 29100 5 5 9 0 40740 7 7 12 5 52380 9 9 16 1 55290 10 5 17 0 66930 12 7 20 6 86053 16 3 26 5 528 448 512 17400 3 3 5 4 26100 4 9 8 0 36540 6 9 11 2 46980 8 9 14 5 49590 9 4 15 3 60030 11 3 18 5 77181 14 6 23 7 784 576 768 15800 3 0 4 9 22600 4 3 7 0 29380 5 6 9 0 38420 7 3 11 8 42940 8 1 13 2 51980 9 8 16 0 67974 12 9 20 9 1040 832 1024 1550...

Reviews: