background image

A.  Activate RDL.  This may be done in two ways:  First, by moving

the front panel toggle switch UP to "Remote".  Second, by raising pin 21
on the RS-232 interface (Note: Make sure DIP switch S3-6 is ON; and
DIP switch S2-6 is OFF).

B.  Perform a BER (bit error rate) test on the system.

C.  If the BER test equipment indicates a fault, and the Local Analog

Loopback test was successful for both Model 1080A Series units, you
may have a problem with the twisted pair line between the modems.
You should then test the twisted pair line for proper connections and
continuity.

5.4.3  Using the V.52 BER Test Independently

The V.52 BER test can be used independently of the V.54 loopback

tests.  This requires two operators:  one to initiate and monitor the test
at the local 1080A/1080A-64, and one at the remote 1080A/1080A-64.
To use the V.52 BER test by itself, both operators should
simultaneously follow these steps:

1.  Locate the “511/511E” toggle switch on the front panel of the unit

and move it UP.  This activates the V.52 BER test mode and
transmits a “511” test pattern to the other unit.  If any errors are
present, the receiving modem's red “ERROR” LED will blink
sporadically.  Note:  For this test to function, the “511” switch on
both 1080A Series units must be on.

2.  If the test indicates no errors are present, move the V.52 toggle

switch DOWN, activating the “511/E” test with periodic errors
present.  If the test is working properly, the receiving modem’s red
“ERROR” LED will blink 

regularly.  A successful “511/E” test will

confirm that the link is in place, and that the Model 1080A Series’
built-in “511” generator and detector are working properly.

5.5  POWER-DOWN

Turn off the Model 1080A Series by simply unplugging the AC

power adapter from the wall.  There is no power switch.

23

24

APPENDIX A

PATTON MODEL 1080A SERIES SPECIFICATIONS

Transmission Format:  

Synchronous or asynchronous, 2-
wire/half duplex, or 4-wire/full or half 
duplex

Interface:

RS-232 (CCITT V.24) connection via 
DB-25 female; twisted pair connection 
via RJ-45 or terminal block

Transmission Line:  

2 or 4-wire UTP, 19 - 24 AWG

Data Rates:  

Model 1080A - Synchronous or 
asynchronous at 1.2, 1.8, 2.4, 3.6, 4.8, 
7.2, 9.6, 14.4, 19.2, 28.8, 38.4, and 57.6 
kbps—switch selectable;
Model 1080A-64 - Synchronous or 
asynchronous at 16, 32, and 64 
kbps—switch selectable 

Clocking:

Internal, external or receive recover

Controls:

Carrier constantly “ON” or “controlled by 
RTS”;  RTS/CTS delay set to no  delay, 7 
or 53 ms

Applications:

Point-to-point or multi-point

Indicators:  

Bi-color LED indicators for TD, RD, RTS 
& DCD; single LED indicators for Test 
and Error

RTS Anti-stream Timer 

12.5 sec., 50 sec., or disabled (switch 
selectable);  tolerance:  +50%, -0

Diagnostics:  

V.52 compliant bit error rate pattern 
(511/511E pattern) generator and 
detector with error injection mode; 
V.54 compliant—Local Analog Loopback 
and Remote Digital Loopback, activated 
by front panel switch or via RS-232 
interface

Transformer Isolation:

1500 V RMS

Surge Protection:

Immune to IEC-801-5 Level 2, 1kV

Temperature:

0-50°C / 32-122°F

Humidity:

0-95%, non-condensing

Dimensions: 

6.2”w x 4.2”h x 1.5”l

Power Supply (US):  

Wall-mount; input: 120 V AC; output: 
10-12 V AC

Summary of Contents for 1080A

Page 1: ...1080A 64 Universal Synchronous Asynchronous Short Range Modems SALES OFFICE 301 975 1000 TECHNICAL SUPPORT 301 975 1007 http www patton com Part 07M1080A D Doc 072041UD Revised 6 19 98 C E R T I F I...

Page 2: ...re designed to provide reasonable protection from such interference in a commercial installation However there is no guarantee that interference will not occur in a particular installation If the Mode...

Page 3: ...tic gain control anti streaming timer transformer isolation to guard against data loss due to ground potential differences and Silicon Avalanche Diode surge protection to guard against data line trans...

Page 4: ...al Figure 2 Close up of DIP switches showing ON and OFF positions 1 2 3 4 5 6 7 8 ON OFF ON Shown in the tables below are DIP Switch settings for Models 1080A and 1080A 64 Switches S1 5 and S1 6 Clock...

Page 5: ...f Normal Operation S2 7 2 Wire 4 Wire Off 4 Wire S2 8 Not Used N A 7 ms 10 bits Switch S2 3 Extended Signaling Rate The setting for switch S2 3 determines the range of variability the Model 1080A Seri...

Page 6: ...e Off S3 3 Not yet assigned n a S3 4 Mode Selection On Point to Point S3 5 Local Loopback Off Disabled S3 6 Remote Loopback Off Disabled S3 7 Anti stream Control Off S3 8 Anti stream Control Off 200 O...

Page 7: ...elded or unshielded Both types yield favorable results The Model 1080A Series offers two methods of twisted pair connection RJ 45 jack and terminal blocks Figure 3 below shows the location of these in...

Page 8: ...ne wire of the pair to a Transmit lug TX or TX on both the local and remote Model 1080A or 1080A 64 C Connect the other wire of the pair to the other Transmit lug on both the local and remote Model 10...

Page 9: ...nnection Via Terminal Blocks If you are not going to use the modular jacks then follow the instructions below A Locate the terminal block on the back of the unit It should look like the following diag...

Page 10: ...led by RTS S1 8 ON Figure 4 illustrates a typical Model 1080A Series multipoint application 4 3 1 Multipoint Twisted Pair Connection The Model 1080A Series supports multipoint applications using a sta...

Page 11: ...odem to RTS control S1 8 On 6 Place both front panel toggle switches to neutral position Test Led will not light 7 Connect both modems to the 4 wire twisted pair cable 20 5 0 OPERATION Once you have c...

Page 12: ...D RD flashing red and green RTS DCD green TEST off 21 5 4 V 54 TEST MODES The Model Series offers two V 54 test modes to evaluate the condition of the modems and the communication link These tests can...

Page 13: ...gularly A successful 511 E test will confirm that the link is in place and that the Model 1080A Series built in 511 generator and detector are working properly 5 5 POWER DOWN Turn off the Model 1080A...

Page 14: ...ance but not functionality Wire should be 26 AWG 4mm or larger smaller AWG Patton products are designed to withstand normal environmental noise and conditions however other environmental factors too n...

Page 15: ...To 1080A 5 CTS Clear to Send From 1080A 6 DSR Data Set Ready From 1080A 7 SG Signal Ground 8 DCD Data Carrier Detect From 1080A To 1080A Analog Loop 18 To 1080A Data Term Ready DTR 20 To 1080A Digita...