background image

APPENDIX A

SPECIFICATIONS

Transmission Format:  Sync. or async.

Transmission Line: Unconditioned twisted pair 19 - 26 AWG

Clocking: Internal, external or receive loopback

Distance: To 6 miles

Interfaces: EIA RS-232, CCITT V.24, CCITT V.35 

Data Rates: 32, 56 and 64 Kbps (switch selectable)

Isolation: Minimum 1500 V RMS via isolation transformers

Surge Protection:  600W power dissipation at 1 mS and response

time of 1 pS

Control Signals:  “Constantly on” or “Controlled by RTS”

RTS/CTS Delay:  No delay, 7mS, 53mS

Connectors: DB-25 female or male on RS-232/V.35 side;  

RJ-11 or RJ-45 on line side

Power Supply:  7.5V DC wall mount transformer

Temperature Range: 0-60°C (32-140°F)

Altitude:  0-15,000 feet

Humidity:  Up to 95% non-condensing

Dimensions:  3.55” x 2.1” x .80”

Weight:  2 oz.

15

APPENDIX B

PIN CONFIGURATIONS

16

1 - (FG) Frame Ground

Common

2 - (TD) Transmit Data

To Model 1045

3 - (RD) Receive Data

From Model 1045

4 - (RTS) Request to Send

To Model 1045

5 - (CTS) Clear to Send

From Model 1045

6 - (DSR) Data Set Ready

From Model 1045

7 - (SG) Signal Ground

Common

8 - (CD) Carrier Detect

From Model 1045

To Model 1045

Data Term. Ready (DTR) - 20

DIRECTION

RS-232 PIN-OUT REFERENCE (DB-25)

DIRECTION

To Model 1045

External Clock - 24

From Model 1045

Transmit Clock - 15   

From Model 1045

Receive Clock - 17

To Model 1045

Local Analog Loopback - 18

From Model 1045 Remote Digital Loopback - 21

From Model 1045

Test Mode - 25

1 - (FG) Frame Ground

Common

2 - Transmit Data A

To Model 1045

3 - Receive Data A

From Model 1045

4 - (RTS) Request to Send

To Model 1045

5 - (CTS) Clear to Send

From Model 1045

6 - (DSR) Data Set Ready

From Model 1045

7 - (SG) Signal Ground

Common

8 - (CD) Carrier Detect

From Model 1045

9 - Receive Clock B

From Model 1045

11 - External Clock B

To Model 1045

12 - Transmit Clock B

From Model 1045

To Model 1045

Data Term. Ready (DTR) - 20

DIRECTION

CCITT V.35 PIN-OUT REFERENCE (DB-25)

DIRECTION

To Model 1045

External Clock A - 24

From Model 1045

Transmit Clock A - 15   

From Model 1045

Receive Clock A - 17

To Model 1045

Local Loopback (LAL) - 18

To Model 1045

Remote Loopback (RDL) - 21

From Model 1045

Test Mode - 25

To Model 1045

Transmit Data B - 14   

From Model 1045

Receive Data B - 16   

Summary of Contents for 1045

Page 1: ...R MANUA L MODEL 1045 Powered High Speed Short Range Modem RS 232 and V 35 versions SALES OFFICE 301 975 1000 TECHNICAL SUPPORT 301 975 1007 http www patton com Part 07M1045 A Doc 054041UA Revised 11 06 96 ...

Page 2: ...Electronics All returns must have a Return Materials Authorization number on the outside of the shipping container This number may be obtained from Patton Electronics Technical Service at 301 975 1007 Packages received without an RMA number will not be accepted Patton Electronics technical staff is also available to answer any questions that might arise concerning the installation or use of your M...

Page 3: ...ation switches OFF 1 2 3 4 5 6 7 8 DHS 8 OFF ON Figure 1 The inside of the Model 1045 OFF 1 2 3 4 5 6 7 8 OFF 1 2 3 4 5 6 7 8 SW1 SW2 3 2 OPENING THE CASE Open the unit by gently inserting a screwdriver into the special pry slot on the plastic case below You don t have to worry about breaking the plastic 3 3 SWITCH SETTINGS All possible settings for the Model 1045 s configuration switches are pres...

Page 4: ...h Off SW1 7 Character Length Off SW1 8 V 54 Enable Disable Off Enabled 10 bits Figure 3 Summary of DIP switch settings for set SW1 SW1 4 Async Sync The setting for switch SW1 4 determines whether the Model 1045 is in asynchronous or synchronous operating mode SW1 4 Setting On Asynchronous Off Synchronous SW1 5 Extended Signalling Rate The setting for switch SW1 5 determines the range of variabilit...

Page 5: ...transmit clock 7 SW2 SUMMARY TABLE Position Function Factory Default SW2 1 Data Rate Off SW2 2 Data Rate On SW2 3 Data Rate Off SW2 4 Clock Source On SW2 5 Clock Source On SW2 6 Carrier Control Off Constantly On SW2 7 RTS CTS Delay On SW2 8 RTS CTS Delay On Internal 56 Kbps Figure 4 Summary of DIP switch settings for set SW2 7 mS SW2 6 Carrier Control Method The setting for switch SW2 6 determines...

Page 6: ...gnal pin relationships are shown on the table on the following page 9 Figure 5 Standard AT T color codes 1 Blue 2 Yellow 3 Green 4 Red 5 Black 6 White 1 Blue 2 Orange 3 Black 4 Red 5 Green 6 Yellow 7 Brown 8 Slate RJ 11 SIGNAL RJ 45 SIGNAL 1 GND 1 N C 2 RCV 2 GND 3 XMT 3 RCV 4 XMT 4 XMT 5 RCV 5 XMT 6 GND 6 RCV 7 GND 8 N C Connection to ground is optional When connecting two Model 1045s it is neces...

Page 7: ... red for a space on transmit data CD Glows red for high on carrier detect BERT Glows red when bit errors occur in test mode 511 pattern Lights when 511 E test pattern has been selected LOOP Glows red when the Model 1045 is in remote digital loopback or local analog loopback mode 12 Figure 6 Model 1045 s LED indicators and test switches TD CD PWR BERT LOOP 511 E RDL NORMAL 511 LAL 4 2 2 CONNECTION ...

Page 8: ...4 test modes on the Model 1045 are available for point to point applications only 5 3 1 Local Analog Loopback LAL The Local Analog Loopback LAL test checks the operation of the local Model 1045 and is performed separately on each unit Any data sent to the local Model 1045 in this test mode will be echoed returned back to the user device For example characters typed on the keyboard of a terminal wi...

Page 9: ...l 1045 6 DSR Data Set Ready From Model 1045 7 SG Signal Ground Common 8 CD Carrier Detect From Model 1045 To Model 1045 Data Term Ready DTR 20 DIRECTION RS 232 PIN OUT REFERENCE DB 25 DIRECTION To Model 1045 External Clock 24 From Model 1045 Transmit Clock 15 From Model 1045 Receive Clock 17 To Model 1045 Local Analog Loopback 18 From Model 1045 Remote Digital Loopback 21 From Model 1045 Test Mode...

Page 10: ...APPENDIX C BLOCK DIAGRAM 17 ...