10.  TIP the top half of the case as necessary to place it over the

strain relief assembly.  Do not snap the case together yet.

11.  Insert one captive screw through a saddle washer and then

insert the entire piece through the hole in the DB-15 end of the case.
Snap that side of the case closed.  Repeat the process for the other
side.  This completes cable installation.

4.2  CONNECTION TO THE RS-232 INTERFACE

Once you have configured the Model 1015 for DTE or DCE and

connected the twisted pair wires correctly, simply plug the 1015 directly
into the DB-15 port of the RS-232 device.  After doing so, remember to
insert and tighten the two captive connector screws.

Note:  If you must use a cable to connect the Model 1015 to the

RS-232, make sure it is a 

straight through

cable of the shortest possi-

ble length—we recommend 6 feet or less.  The Model 1015 requires a
cable that incorporates pins 1, 2, 3, 4, 9, 10, 11 and 12.

4.3  OPERATING THE MODEL 1015

Once the Model 1015 is properly installed, it should operate trans-

parently—as if it were a standard cable connection.  Operating power
is derived from the RS-232 data and control signals; there is no
“ON/OFF” switch.  All data signals from the RS-232 interface are
passed straight through.  All control signals from the RS-232 interface
are looped back.

Note:  If your system requires 

hardware

flow control, you will need

the Patton Model 1012 or Model 1060 Short Range Modem.  Call
Patton Customer Service at (301) 975-1007 for more information.

APPENDIX A

PATTON MOCEL 1015 SPECIFICATIONS

Transmission Format:  Asynchronous

Data Rate:  

0 to 19,200 bps (no strapping)

Surge Protection:  

600W peak power dissipation at 1 mS   
(10 x 1000 µs exponential waveform) and 
response time of 1.0 pS

Control Signal:  

CTS (Pin 10) turns ON immediately after 
the terminal raises RTS (Pin 2); DSR (Pin 3)
turns on when powered up; DCD (Pin 12) 
turns on immediately after the terminal 
raises DTR (Pin 4)

Transmit Line:  

4 wire, unconditioned line (2 twisted pairs)

Transmit Mode

Full duplex, 4-wire

Transmit Level

 0 

dBm

Line Connection:  

RJ-11 or RJ-45 jack or 5 screw terminal 
posts (4 wires and 1 ground) and a strain 
relief insert

Power Supply:  

No external power required, uses ultra low 
power from EIA data and control signals

Size:

2.6” x 1.3” x 0.75”

9