APPENDIX B

PATTON MODEL 1006 CABLE RECOMMENDATIONS

The Patton Model 1005 operates at frequencies of 20kHz or less

and has been performance tested by Patton technicians using twisted-
pair cable with the following characteristics:

Wire Gauge

Capacitance

Resistance

19 AWG/.9mm 83nf/mi or 15.72 pf/ft. .0163 Ohms/ft.
22 AWG/.6mm 83nf/mi or 15.72 pf/ft. .0326 Ohms/ft.
24 AWG/.5mm 83nf/mi or 15.72 pf/ft. .05165 Ohms/ft.

To gain optimum performance from the Model 1006, please keep

the following guidelines in mind:

• 

Always

use

 twisted pair wire

—this is not an option.

• Use twisted pair wire with a capacitance of  20pf/ft or less.

• Avoid twisted pair wire thinner than 26 AWG (i.e. avoid higher 

AWG numbers than 26)

• Use of twisted pair with a resistance greater than the above 

specifications may cause a reduction in maximum distance 
obtainable.  Functionality should not be affected.

• Environmental factors too numerous to mention can affect the 

maximum distances obtainable at a particular site.  Use “maximum 
distance” figures as a

 general guideline only.

APPENDIX C

PATTON MODEL 1006 PIN/SIGNAL ASSIGNMENTS

1- (FG) Frame Ground
2- (TD) Transmit Data To Model 1006
3- (RD) Receive Data From Model 1006
4- (RTS) Request to Send To Model 1006
5- (CTS) Clear to Send From Model 1006
6- (DSR) Data Set Ready From Model 1006
7- (SG) Signal Ground
8- (DCD) Data Carrier Detect From Model 1006

To Model 1006 Data Term. Ready (DTR) - 20

DIRECTION STANDARD “DCE” SETTING DIRECTION

1- (FG) Frame Ground
2- (TD) Transmit Data From Model 1006
3- (RD) Receive Data To Model 1006
4- (RTS) Request to Send From Model 1006
5- (CTS) Clear to Send To Model 1006
6- (DSR) Data Set Ready To Model 1006
7- (SG) Signal Ground
8- (DCD) Data Carrier Detect To Model 1006

From  Model 1006 Data Term. Ready (DTR) - 20

DIRECTION STANDARD “DTE” SETTING DIRECTION

11 12

Summary of Contents for 1006

Page 1: ...DB 9 Async Short Range Modem with Carrier Sense SALES OFFICE 301 975 1000 TECHNICAL SUPPORT 301 975 1007 http www patton com Part 07M1006 C Doc 060011UC Revised 4 29 98 USER MANUAL An ISO 9001 Certifi...

Page 2: ...o provide reasonable protection from such interference in a commercial installation However there is no guarantee that interference will not occur in a particular installation If the Model 1006 does c...

Page 3: ...ng installation or use of this product please do not hesitate to contact Patton Electronics Technical Support at 301 975 1007 2 1 FEATURES Ideal for UNIX operating systems Range to 17 miles 27 2 km Da...

Page 4: ...am below shows how a crossover cable should be constructed for an environment where both Model 1006s use a 4 wire RJ 11 connector Similar logic should be followed when using RJ 45 connectors or a comb...

Page 5: ...on the terminal block making careful note of which color is positive and which color is negative 5 Connect the other pair of wires to RCV and RCV receive positive and negative on the terminal block ag...

Page 6: ...it over the strain relief assembly Do not snap the case together yet 11 Insert one captive screw through a saddle washer and then insert the entire piece through the hole in the DB 9 end of the case S...

Page 7: ...se a reduction in maximum distance obtainable Functionality should not be affected Environmental factors too numerous to mention can affect the maximum distances obtainable at a particular site Use ma...

Page 8: ...APPENDIX B PATTON MODEL 1006 BLOCK DIAGRAM Copyright 1998 Patton Electronics Company All Rights Reserved 13...

Reviews: