10. Troubleshooting guide
Faults
Cause
Remedy
The equip-
ment does
not start
- Power supply not con-
nected
- Check power supply
The equip-
ment does
not pump
- Intake sieve clogged
- Discharge hose kinked
- Clean intake sieve with
water jet
- Unkink the hose
Insu
ffi
cient
pumping rate
- Intake sieve clogged
- Performance reduced
due to heavily conta-
minated and abrasive
water impurities
- Clean intake sieve
- Clean equipment and
replace wear parts
The equip-
ment swit-
ches o
ff
after
brie
fl
y run-
ning
- Motor circuit-breaker
switches the equipment
o
ff
due to excessive
water contamination
- Water temperature
too high; motor circuit-
breaker switches the
equipment o
ff
- Unplug power plug and
clean equipment and
shaft
- Ensure that maximum
permissible water tem-
perature (35 °C) is not
exceeded