background image

RENTQUIP USA INC.  |  1-800-818-1199  |  WWW.PATRONPRODUCTS.COM

E3 PRODUCT MANUAL

RENTQUIP USA INC.  |  1-800-818-1199  |  WWW.PATRONPRODUCTS.COM

MAINTENANCE

WARNING!

NEVER SERVICE THE HEATER WHILE IT IS PLUGGED IN, RUNNING OR HOT. SEVERE BODILY INJURE 

OR ELECTRIC SHOCK MAY OCCUR.

ONLY QUALIFIED PERSONS ARE ALLOWED TO OPEN HEATER FOR SERVICE. NO USER-SERVICE-

ABLE PARTS INSIDE.

•  Keep heater clean. Use pressurized air to blow fan blades clean. Note! Use moderate pressure to avoid 

damage to fan blades

•  Inspect heater before and after each use

•  The fan motor is sealed and has permanently lubricated bearings

STORAGE

When not in use, the heater must be disconnected from power source, cleaned of dust and stored in a dry 

place.

The power supply cord should be loosely wound around the handle of the heater.

TECHNICAL SPECIFICATIONS

HEAT OUTPUT

BTU/Hr

10,200 (3,000W)

AIRFLOW

CFM

205

ELECTRIC CONNECTION

V ac / Hz

240 / 60 single phase

AMPERAGE DRAW

A

12.5

POWER CORD

3x16 AWG

PLUG

NEMA 6-15P

EXTENSION CORD

min. 3x12 AWG

AMBIENT THERMOSTAT

temp. range

32 - 100 °F  (0 - 40 °C)

LENGTH

inches

11.8

WIDTH

inches

10.2

HEIGHT

inches

15.2

WEIGHT

lbs

20.3

Summary of Contents for E3

Page 1: ...EAD AND UNDERSTAND THIS MANUAL BEFORE ASSEM BLING STARTING OR SERVICING THE HEATER IMPROPER USE OF HEATER CAN CAUSE SERIOUS INJURY KEEP THIS MANUAL FOR FUTURE REFERENCE FOR PROFESSIONAL USE ONLY RENTQ...

Page 2: ...l into a bathtub or other liquid container 7 Do not run cord under carpeting Do not cover cord with throw rugs runners or the like Arrange cord away from traffic area and where it will not be tripped...

Page 3: ...r than those provided by an authorized PATRON service THERE ARE NO OBLIGATIONS OR LIABILITIES ON THE PART OF PATRON PRODUCTS INC FOR CON SEQUENTIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH THE USE...

Page 4: ...supply plug NOTE THE HEATER IS EQUIPPED WITH AN OVERHEAT LIMIT SWITCH WHICH MAY CAUSE THE HEATER TO STOP CHECK AND REMOVE THE CAUSE FOR OVERHEATING BEFORE RESTARTING 3 OPERATION REVIEW AND UNDERSTAND...

Page 5: ...nspect heater before and after each use The fan motor is sealed and has permanently lubricated bearings STORAGE When not in use the heater must be disconnected from power source cleaned of dust and st...

Page 6: ...heat Limit Switch 7 14104 Fan Motor 8 16200 Fan Blade 9 36910 Strain Reliever 10 80100 Handle 11 20405 Ambient Thermostat 12 17907 Fan Hub Plastic 13 20405 Ambient Thermostat 14 493406 Bracket Termina...

Page 7: ...ock X2 n a Grounding Lug X3 30320 Power Cord Plug Pos Patron E3 Code M fan motor motor du ventilateur 14104 R heating element element 42800 S2 room thermostat thermostat ambiant 20405 S3 overheat limi...

Page 8: ...PATRON PRODUCTS A DIVISION OF RENTQUIP 1 800 818 1199 www patronproducts com...

Reviews: