RENTQUIP USA INC. | 1-800-818-1199 | WWW.PATRONPRODUCTS.COM
E1.5 PRODUCT MANUAL
RENTQUIP USA INC. | 1-800-818-1199 | WWW.PATRONPRODUCTS.COM
MAINTENANCE
WARNING!
NEVER SERVICE THE HEATER WHILE IT IS PLUGGED IN, RUNNING OR HOT. SEVERE BODILY INJURE
OR ELECTRIC SHOCK MAY OCCUR.
ONLY QUALIFIED PERSONS ARE ALLOWED TO OPEN HEATER FOR SERVICE. NO USER-SERVICE-
ABLE PARTS INSIDE.
• Keep heater clean. Use pressurized air to blow fan blades clean. Note! Use moderate pressure to avoid
damage to fan blades
• Inspect heater before and after each use
• The fan motor is sealed and has permanently lubricated bearings
STORAGE
When not in use, the heater must be disconnected from power source, cleaned of dust and stored in a dry
place.
The power supply cord should be loosely wound around the handle of the heater.
TECHNICAL SPECIFICATIONS
HEAT OUTPUT
BTU/Hr
5,100 (1,500W)
AIRFLOW
CFM
116
ELECTRIC CONNECTION
V ac / Hz
120 / 60 single phase
AMPERAGE DRAW
A
12.5
POWER CORD
3x16 AWG
PLUG
NEMA 5-15P
EXTENSION CORD
min. 3x12 AWG
AMBIENT THERMOSTAT
temp. range
32 - 100 °F (0 - 40 °C)
LENGTH
inches
14.5
WIDTH
inches
7.9
HEIGHT
inches
12.2
WEIGHT
lbs
13.7