![Patron 18E Series Product Manual Download Page 4](http://html1.mh-extra.com/html/patron/18e-series/18e-series_product-manual_4012737004.webp)
18E PRODUCT MANUAL
RENTQUIP USA INC. | 1-800-818-1199 | WWW.PATRONPRODUCTS.COM
OPERATION
REVIEW AND UNDERSTAND ALL WARNINGS IN THIS MANUAL. THEY ARE ESSENTIAL FOR SAFE USE
OF THE HEATER.
FOLLOW ALL LOCAL CODES
TO START HEATING:
1. Place the heater on a stable and level surface. Make sure that no explosive or combustible fumes or dust
are present.
MINIMUM CLEARANCES FROM COMBUSTABLE MATERIALS
OUTLET = 6 feet
SIDES = 1 foot
TOP = 2 feet
REAR = 2 feet
FLOOR = COMBUSTABLE
2. Connect power cord of heater into 240 V / 60 Hz power source. THE POWER SOURCE MUST BE
EQUIPPED WITH A CIRCUIT BREAKER! See paragraph “Technical specifications” in this manual for cor
-
rect amperage rating. NOTE: Check your heater to make sure it is wired for either one or three phase use.
3. Set the room thermostat to a temperature above the ambient room temperature by turning the knob. Note!
The heater will start heating only if the thermostat “calls for heat” meaning that it is set to higher than pre
-
vailing ambient temperature
4.
Turn the main switch into position 2 = ”Output 13,000 W” for partial heating output or into position 3 =
”Output 19,000 W” for full heating output. THE HEATER WILL NOW OPERATE AUTOMATICALLY, CON
-
TROLLED BY THE THERMOSTATS.
5.
When no heating is needed, turn the main switch into position 1 = ”Ventilation only” for air circulating pur
-
poses.
TO STOP HEATING
1.
Turn the main switch into position “0” standby
2. Let the fan cooldown heater for 2-3 minutes
3. Disconnect the power supply plug
NOTE!
THE HEATER IS EQUIPPED WITH AN OVERHEAT LIMIT SWITCH WHICH MAY CAUSE THE HEATER TO
STOP. CHECK AND REMOVE THE CAUSE FOR OVERHEATING BEFORE RESTARTING.
RENTQUIP USA INC. | 1-800-818-1199 | WWW.PATRONPRODUCTS.COM