Patriot PS5 User Manual Download Page 4

-

 

Check your installation to ensure that it complies 

with all local safety regulations. 

-

 

Do not connect simultaneously to a fence and to 

any other device such as a cattle trainer or a 
poultry trainer. Otherwise, lightning striking your 
fence will be conducted to all other devices. 

 

 

Safe electric fence construction 

Warning!

  Read before use. 

An electric fence can be hazardous when there is a risk 
of entrapment or entanglement, or other hazards exist. 
Serious injury or death may result. Take all steps to 
avoid the risk of entrapment or entanglement. 

Hazards 

:

 

Do not climb through or under an electric fence. If it 
is necessary to cross an electric fence use a gate or 
specially designed crossing point. 

:

 

Do not allow young or infirm persons to use this unit 
without supervision. Do not allow young children to 
play with this unit or near an electric fence or 
electrified wires. 

:

 

Do not electrify barbed wire. 

:

 

Do not support off-set electrified wires less than 6” 
(150 mm) from a barbed wire fence. 

:

 

Do not electrify any fence construction which could 
lead to entanglement of persons or animals. We 
recommend for instance, that no more than one 
electrified off-set wire be supported on either side of 
a barbed wire or mesh fence. 

:

 

Do not supply an electric fence from two units. 

:

 

Do not allow electrified wires from two units on the 
same or adjacent properties to be less than 6’6” 
(2 m) apart. 

:

 

Do not place the unti’s ground electrode within 33’ 
(10 m) of any part of a power supply ground system 
or telecommunications ground system. 

:

 

Do not run electric fence wires above or close to 
overhead power or communication lines. 

 

Duty to the public 

A warning sign shall be fitted to every point where 
persons may gain ready access to the conductors. 
Where an electric animal fence crosses a public 
pathway, a non-electrified gate shall be incorporated 
in the electric animal fence at that point or a crossing 
by means of stiles shall be provided. At any such 
crossing, the adjacent electrified wires shall carry 
warning signs.  
Any part of an electric animal fence that is installed 
along a public road or pathway shall be identified at 
frequent intervals by warning signs securely fastened 
to the fence posts or firmly clamped to the fence wires. 

 

The size of the warning sign shall be at least 
4x8” (100x200 mm). 

 

The background colour of both sides of the 
warning sign shall be yellow. The inscription on 
the sign shall be black and shall be either: 

 

or the substance of “CAUTION: Electric fence”. 

 

The inscription shall be indelible, inscribed on 
both sides of the warning sign and have a height 
of at least 1” (25 mm). 

 

Definition of special terms 

Unit/Charger/Energizer 

– An appliance that is intended 

to periodically deliver voltage impulses to a fence 
connected to it.

 

Fence 

– A barrier for animals or for the purpose of 

security, comprising one or more conductors such as 
metal wires, rods or rails. 

Electric fence 

– A barrier which includes one or more 

electric conductors, insulated from ground, to which 
electric pulses are applied by a unit. 

Ground electrode 

– Metal structure that is driven into 

the soil near a unit and connected electrically to the 
Fence ground terminal of the unit, and that is 
independent of other grounding arrangements. 

Connecting lead 

– An electric conductor, used to 

connect the unit to the electric fence or the ground 
electrode. 

Summary of Contents for PS5

Page 1: ...lified personnel No user serviceable parts Read full instructions before use This unit must NOT be disposed of with other normal waste Instead it is your responsibility to dispose of it correctly by h...

Page 2: ...nit The unit can be mounted to a wooden post or other surface using two 10 gauge galvanized screws 1 Insert the screws into the Mounting points at the top of the carry handle 2 Tighten the screws ensu...

Page 3: ...r local dealer The battery must only be replaced with a 4 V 4 5 Ah sealed rechargeable battery Do not use a non rechargeable battery Contact your local dealer if you are unsure Maintenance and storage...

Page 4: ...close to overhead power or communication lines Duty to the public A warning sign shall be fitted to every point where persons may gain ready access to the conductors Where an electric animal fence cro...

Page 5: ...ffectively insulated from the grounded structural parts of the building This may be achieved by using insulated high voltage cable Connecting leads that are run underground shall be run in conduit of...

Page 6: ...of protection IPX4 Product specifications Peak output energy 50 mJ Peak stored energy 70 mJ Period between pulses charged battery 2 s Maximum output voltage up to 7 5 kV Rated load performance 2000 3...

Page 7: ...nto con los residuos dom sticos M s bien es su responsabilidad desechar correctamente el residuo del aparato entreg ndolo en un punto de recogida de una autoridad local responsable del reciclaje de re...

Page 8: ...dor est correctamente posicionado y que no se mueva con el viento Conectar el energizador a una cerca el ctrica 1 Entierre completamente en el suelo firme una varilla de toma a tierra de acero galvani...

Page 9: ...a el energizador y la bater a a su distribuidor local La bater a s lo debe ser reemplazada por una bater a sellada recargable de 4 V 4 5 Ah No utilice una bater a no recargable P ngase en contacto con...

Page 10: ...les Recomendamos que se apoye s lo un alambre electrificado en ambos lados de una cerca de espino o de mallas met licas No alimente nunca una cerca el ctrica con dos energizadores La distancia entre a...

Page 11: ...es no conductivos o una barrera met lica aislada Tanto el alambre de espino como el alambre de arista viva no deber n ser electrificados por un energizador Una cerca no electrificada con alambre de es...

Page 12: ...esultado satisfactorio y seguro Si se desean usar cercas el ctricas para animales para apartar p jaros de edificios no se debe conectar ning n alambre de cerca el ctrica al electrodo a la varilla de t...

Page 13: ...ordinaires Il est de votre responsabilit de l liminer correctement en l apportant une autorit locale responsable de la collecte de d chets d quipements lectriques et lectroniques Installation Pour me...

Page 14: ...une cl ture lectrique 1 Enfoncez un piquet de terre en acier galvanis de 3 1 m dans un sol ferme dans un rayon de 15 5 m autour de l lectrificateur 2 Connectez un fil de calibre 20 9 AWG 0 51 mm 6 6...

Page 15: ...lectrificateur et la batterie votre concessionnaire local La batterie ne doit tre remplac e que par une batterie rechargeable scell e 4 V 4 5 Ah N utilisez pas de batterie non rechargeable En cas de...

Page 16: ...0 mm d un fil barbel N lectrifiez jamais une cl ture qui pourrait entra ner un risque d emm lement pour l homme ou les animaux Nous vous recommandons par exemple de n installer qu un seul fil d cal le...

Page 17: ...es pour animaux s par es chacune aliment e par un lectrificateur ind pendant la distance entre les fils des deux cl tures lectriques pour animaux sera au moins de 8 2 5 m Si cette s paration doit tre...

Page 18: ...une alimentation par un lectrificateur faible puissance pour obtenir une performance satisfaisante et fiable Si les cl tures lectriques pour animaux sont utilis es pour loigner les oiseaux ou pour les...

Page 19: ...tom or otherwise Garant a de 1 a o a partir de la fecha de la compra La garant a de este producto cubre defectos de materiales y de fabricaci n durante un periodo de 1 a o A PARTIR DE LA FECHA DE LA C...

Page 20: ...la survenue qu elles manent d une loi d une prescription du secteur commercial des us et coutumes etc 2011 Tru Test Limited All product names and brand names in this document are trademarks or registe...

Reviews: