background image

 

Connecting leads and electric animal fence wires shall not 
cross above overhead power or communication lines. 
Crossings with overhead power lines shall be avoided 
wherever possible. If such a crossing cannot be avoided it shall 

be made underneath the power line and as nearly as possible 
at right angles to it. 
If connecting leads and electric animal fence wires are installed 
near an overhead power line, the clearances shall not be less 
than those shown in the table below. 

Minimum clearances from power lines for electric animal 
fences

 

Power line voltage 

Clearance 

1000 V 

3 m (10’) 

>1000  

33,000 V 

4 m (13’) 

>33,000 V 

8 m (27’) 

 
If connecting leads and electric animal fence wires are installed 

near an overhead power line, their height above the ground 
shall not exceed 3 m (10’). This height applies to either side of 
the orthogonal projection of the outermost conductors of the 

power line on the ground surface, for a distance of: 

• 

2 m (6’6”) for power lines operating at a nominal voltage 

not exceeding 1000 V. 

• 

15 m (50’) for power lines operating at a nominal voltage 
exceeding 1000 V. 

Electric animal fences intended for deterring birds, household 
pet containment or training animals such as cows need only 

be supplied from low output electric fence controllers to 
obtain satisfactory and safe performance. 
In electric animal fences intended for deterring birds from 
roosting on buildings, no electric fence wire shall be 
connected to the electric fence controller ground electrode. A 

warning sign shall be fitted to every point where persons may 
gain ready access to the conductors. 
Where an electric animal fence crosses a public pathway, a 
non-electrified gate shall be incorporated in the electric animal 
fence at that point or a crossing by means of stiles shall be 

provided. At any such crossing, the adjacent electrified wires 
shall carry warning signs.  
Any part of an electric animal fence that is installed along a 
public road or pathway shall be identified at frequent intervals 
by warning signs securely fastened to the fence posts or firmly 

clamped to the fence wires. 

• 

The size of the warning sign shall be at least 

100x200 mm (4x8”). 

• 

The background colour of both sides of the warning sign 
shall be yellow. The inscription on the sign shall be black 
and shall be either: 

 

or the substance of “CAUTION: Electric animal fence”. 

• 

The inscription shall be indelible, inscribed on both sides 

of the warning sign and have a height of at least 
25 mm (1”). 

Ensure that all mains-operated, ancillary equipment connected 
to the electric animal fence circuit provides a degree of 

isolation between the fence circuit and the supply mains 
equivalent to that provided by the electric fence controller. 
Protection from the weather shall be provided for the ancillary 
equipment unless this equipment is certified by the 
manufacturer as being suitable for use outdoors, and is of a 

type with a minimum degree of protection IPX4.

Servicing

 

This electric fence controller contains no user serviceable parts.  

It must be returned to a Patriot-appointed service agent for 
repair.  

 

Summary of Contents for PS15

Page 1: ...F L E X I B IL I T Y D E S I G N VA L U E F L E X I B IL I T Y D E S I G N VA L U E SOLAR POWERED ELECTRIC FENCE CONTROLLER PS15 INSTRUC TION MANUAL W A R NI N G R E A D A L L I N S T R UC T I O NS...

Page 2: ...rademarks of Tru Test Corporation Limited No part of this publication may be photocopied reproduced stored in a retrieval system or transmitted in any form or by any means electronic mechanical photoc...

Page 3: ...es an electric fence controller and an insulated fence The electric fence controller puts very short pulses of electricity onto the fence line These pulses have a high voltage but are of very short du...

Page 4: ...lse every 1 seconds Low A pulse every 3 seconds Note If the pulse indicator light flashes quickly several times and then there is a pause there may be a problem with the electric fence controller Retu...

Page 5: ...person may come into contact with the electric fence without the protection of a physical barrier Requirements for electric animal fences Electric animal fences and their ancillary equipment shall be...

Page 6: ...o the electric fence controller ground electrode A warning sign shall be fitted to every point where persons may gain ready access to the conductors Where an electric animal fence crosses a public pat...

Page 7: ...gth of the fence or reduce the number of fence wires Alternatively divide the fence line into smaller zones with each zone powered by a separate electric fence controller The pulse speed is irregular...

Page 8: ...S AV E T H E S E I N S T R UC T I O NS w w w p a t r i ot g l o b a l c o m...