GAS CONVERSION
Conversion from Natural Gas (NG) to Liquid Propane (LP) or vice versa may only be performed by an authorized service agent.
CLEANING
It is important to clean and check the range daily. Cleaning and checking the range regularly can avoid serious accidents. Stop using if
user feels that there is a problem with the range.
1.
Before cleaning, turn off all gas valves.
2.
Clean the burners and drip tray of all debris and spillage daily. A complete cleaning every day will ensure a good service and
extend the service life of the range.
3.
Clean the stainless steel surface with warm soapy water every day and rinse it completely. Do not saturate range with water,
excessive water will cause operational issues. During cleaning, do not clean the stainless steel surface with abrasive
detergents, brushes, scraper etc. The residual iron scale may cause rusting.
4.
Do not clean the surface with chlorine cleanser (bleach, dish detergent, hydrochloric acid etc.). Do not clean the
floor where the device locates with corrosive substance.
5.
Do not change the burner shutter settings.
6.
Accumulation of substances containing salt or acidic ingredients, e.g., vinegar, lemon juice, spices, salt etc. can cause
corrosion. Please do not allow these substances to have long contact with the unit.
7.
After cleaning, ensure that the ports of the burners are open and clear of any residue.
8.
Clean cast iron top grates with a mild soap and water solution. Rinse thoroughly and dry with a clean towel. Immediately after
drying, season grates lightly with liquid vegetable oil. After seasoning, replace grates on range and turn burners on LOW, allow grates
to heat for 15 minutes before using pots or pans on the range top. Failure to season grates after cleaning will result in rust.
9.
If the range sits idle for a significant period, please turn off the gas valve upstream the range.
TROUBLESHOOTING
Problem
Possible Causes
Solution
The pilot flame can’t be ignited
The gas pressure is too low
Adjust the relieve valve to
increase pressure
The pilot flame can’t be ignited
The nozzle is clogged
Unclog the nozzle
The pilot flame can’t be ignited
Connection of the thermocouple is
loose
Tighten the thermocouple
The pilot flame can’t be ignited
The thermocouple is defective
Replace the thermocouple