background image

GAS CONVERSION

 

Conversion from Natural Gas (NG) to Liquid Propane (LP) or vice versa may only be performed by an authorized service agent. 

CLEANING 

 It is important to clean and check the range daily. Cleaning and checking the range regularly can avoid serious accidents. Stop using if 

user feels that there is a problem with the range. 

1.

Before cleaning, turn off all gas valves.

2.

Clean the burners and drip tray of all debris and spillage daily.  A complete cleaning every day will ensure a good service and
extend the service life of the range.

3.

Clean the stainless steel surface with warm soapy water every day and rinse it completely. Do not saturate range with water,
excessive water will cause operational issues.  During cleaning, do not clean the stainless steel surface with abrasive
detergents, brushes, scraper etc. The residual iron scale may cause rusting.

4.

Do not clean the surface with chlorine cleanser (bleach, dish detergent, hydrochloric acid etc.). Do not clean the
floor where the device locates with corrosive substance.

5.

Do not change the burner shutter settings.

6.

Accumulation  of  substances  containing  salt or acidic  ingredients,  e.g.,  vinegar,  lemon  juice,  spices,  salt  etc. can cause
corrosion. Please do not allow these substances to have long contact with the unit.

7.

After cleaning, ensure that the ports of the burners are open and clear of any residue.

8.

Clean cast iron top grates with a mild soap and water solution.  Rinse thoroughly and dry with a clean towel.  Immediately after
drying, season grates lightly with liquid vegetable oil.  After seasoning, replace grates on range and turn burners on LOW, allow grates
to heat for 15 minutes before using pots or pans on the range top.  Failure to season grates after cleaning will result in rust.

9.

If the range sits idle for a significant period, please turn off the gas valve upstream the range.

TROUBLESHOOTING 

Problem 

Possible Causes 

Solution 

The pilot flame can’t be ignited

 

The gas pressure is too low

 

Adjust the relieve valve to 
increase pressure

 

The pilot flame can’t be ignited

 

The nozzle is clogged

 

Unclog the nozzle

 

The pilot flame can’t be ignited

 

Connection of the thermocouple is 
loose

 

Tighten the thermocouple

 

The pilot flame can’t be ignited

 

The thermocouple is defective

 

Replace the thermocouple

 

Summary of Contents for PLATINUM PT-RGR36C

Page 1: ...arding your purchased equipment Please read the manual thoroughly prior to equipment set up operation and maintenance Failure to comply with regular maintenance guidelines outlined in this manual may...

Page 2: ...GAS ODOR IS DETECTED TURN OFF GAS AT MAIN SHUTOFF VALVE AND CONTACT THE LOCAL GAS COMPANY OR GAS SUPPLIER FOR SERVICE WARNING IMPROPER INSTALLATION ADJUSTMENT ALTERATION SERVICE OR MAINTENANCE CAN CA...

Page 3: ...burner Never attempt to move grates while cooking BEFORE INSTALLATION Installation of this device should be performed by a professional licensed technician Installation of this unit should conform to...

Page 4: ...at a gas shut off valve should be installed upstream the device where it is easily reached during operation 4 Make sure you are using the correct gas supply that is specified for this model If the gas...

Page 5: ...Max To set the flame to Min rotate counterclockwise another 90 degrees When finished turn off main burner by rotating the knob clockwise to off position Pilot should remain lit For complete shutdown...

Page 6: ...ot change the burner shutter settings 6 Accumulation of substances containing salt or acidic ingredients e g vinegar lemon juice spices salt etc can cause corrosion Please do not allow these substance...

Page 7: ...d off The air shutter is too open Adjust the damper It has a light back sound when the gas supply is turned off Gas pressure too low Increase the gas pressure It has a light back sound when the gas su...

Page 8: ...ntiguous United States Hawaii and metropolitan areas of Alaska and Canada may vary The following conditions are not covered by warranty Equipment failure relating to improper installation improper uti...