2
Systematics, Inc. West Chester, PA. 19380
ELECTRODE
GAS NOZZLE
SHIELDING GAS
WORK
ELECTRODE
GAS NOZZLE
SHIELDING GAS
WORK
Welder controls are simple and
clearly marked. The output voltage
is controlled by a twelve position
tap switch, providing 4 TIG and 8
MIG voltage selections. Wire feed
speed is controlled by the wire
speed potentiometer.
SPECIFICATIONS
PART NUMBER:
PBE250
INPUT POWER REQUIREMENTS:
Voltage
208/230
Phase
single phase
Frequency
50/60 hertz
Current
33/30
OUTPUT POWER
@ 60% Duty Cycle:
- 200 Amps
@ 35% - 250 Amps
DUTY CYCLE TIME PERIOD:
10 minutes
OPEN CIRCUIT VOLTAGE:
18 - 42 volts DC
ARC VOLTAGE:
14 - 28 volts DC
WELD CURRENT RANGE:
30 - 250 amps
WIRE TYPES:
mild steel,
Recommended (for steel)
ER70S-6
stainless steel, aluminum,
bronze, flux cored,
flux cored - gasless
WIRE SIZES:
.023" - .045" steel,
3/64" aluminum,
(.023" - 3/64" alum. w/spool gun)
.030" - .035" bronze,
.030" - .045" flux cored
(gas shielded or gasless)
Recommended Size: Aluminum
.035
Others
.030
SHIELDING GASES:
For Steel
CO2 or Argon/CO2 mix
Recommended (for steel) 75% Argon/
25% CO2
For Aluminum, Bronze
Argon
For Stainless Steel
Argon/2% Oxygen
For Flux cored
CO2 or
Argon/CO2 mix
GLOBULAR TRANSFER
Globular transfer occurs at the
intermediate range of 22 to 24 arc
volts, depending on wire size. As
the name implies, the transfer
takes place in the form of irregu-
larly shaped globules. Globular
transfer is useful in cases where a
lower heat input than that of true
spray is required.
SPRAY TRANSFER
Spray transfer occurs at 22 to 32
arc volts, depending on wire size.
The length of the arc is held
constant by the voltage available.
The higher voltage and current
causes the electrode wire to melt
off before touching the workpiece.
The molten metal crosses the gap to
the workpiece in a spray form.
Spray transfer is used in the down-
hand position and provides higher
deposition rates than short arc
transfer or globular transfer.
DESCRIPTION
The PBE250 consists of a combina-
tion MIG welding power source and
wire feed unit, a MIG torch with 10
foot cable, a ten foot work cable
with clamp, a twenty foot power
input cable, a gas regulator -
flowmeter, a torch accessory kit,
and a built-in cylinder rack and
industrial wheel kit.
FIG. 3. GLOBULAR TRANSFER
FIG. 4. SPRAY TRANSFER