8. Function Details
Clear Input Line
8.2.3 Function to Determine Simultaneous Input of Signal Tower Control Line and External Input Line
When multiple changes in Signal Tower control lines and external input lines occur at the same time, use this
function to adjust the period for determining simultaneous input. Select from 3 levels of adjustment [High sensitivity],
[Medium sensitivity], and [Low sensitivity].
8.2.4 Determine Clear Input Line Function
・
On detecting a change in state in the clear input line, this function determines the input status. Use with “8.1.3 Re-
lease Remote Control Function(☞P.47)”.
Tube color: Gray
Tube color: Black
Power Supply Wire
Red
Black
Orange
Green
Blue
White
Amber
Amber
Flashing Common Line
Brown
Brown
Power Supply Wire
Purple
Red
Orange
Green
Blue
White
Purple
Gray
External Input Common line
Gray
Clear Input
External Input 7
External Input 8
External Input 1
External Input 2
External Input 3
External Input 4
External Input 5
External Input 6
LED Red
LED Amber
LED Green
LED Blue
LED White
Buzzer
RS-232C Connection
・
The determine clear input operation occurs when the clear input line changes from OFF to ON.
* The timing for clear input line determination does not change, regardless of the setting of Determine Signal Tower Control
Line Input.
CAUTION
Maintain each of the clear input line's OFF and ON states for 100 ms or longer. It is difficult to determine state changes
when they occur faster than 100 ms.
O N
OFF
Input Red
O N
OFF
Light off
Light on
Result Red
Input Green
Light on
Light off
Result Green
T (input deviation)
CAUTION
When state changes of multiple inputs are not determined to be simultaneous, make adjustments with this function.
Even after adjustments, if simultaneous input does not occur, adjust by making a change in the actual input.
Result*
T
High sensitivity
up to 20ms
Medium sensitivity
up to 40ms
Low sensitivity
up to 60 ms
* The default setting is [High sensitivity].