background image

-8-

(Unit

mm)

 

  Using this template

1. Confirm the hole position on the product.
2. Secure the template to the installation surface
    using adhesive tape.
3. Mark the installation holes using a nail punch, 

etc.

4. Drill the holes in the  installation surface.

 Confirm the direction of the name plate and the

     wiring route before you drill the holes.

φ

30

3-120

°

Wiring thru
 hole 

φ

12

Installation
 hole 3-

φ

4

5

Name plate
position

Buzzer transmission

direction

5. Installation 

Mounting

 Drill mounting holes in the wall or panel. (See the following installation diagram.)

 Secure the side mounting bracket with hex bolts and hex nuts (not supplied) .

 Install the Signal Tower vertically at a location that has sufficient strength and minimal vibration.

 With buzzer models, the alarm can be heard best from the front direction.

     Therefore, make sure the Signal Tower is facing the correction direction before installation.

 This product can be used only indoors. (Do not use it outdoors.)

 Do not install the Signal Tower sideways or inverted.

 Make sure of the specified operating voltage and current before use.

 Do not leave the product or use it without LED unit installed.

 Use the soft cloth with moisture when the LED unit or bodies must be cleaned

 

 up. (Do not use thinner, benzine, gasoline or oil.)

 When installing this product, do not twist the product with excessive torque or

    the product may be damaged.

 During installation, do not remove the waterproof sheet. It may cause a malfunction.

 This product has 1mm thick waterproof packing at the bottom of the pole

 

 bracket. However, when complete waterproofing is not provided due to the

 

 unevenness of the installation surface, apply waterproof sealant between

 

 the unit and the installation surface to maintain waterproof conditions.

 For use on a flat surface of a Type 1 Enclosure.

 For the model LCE-

02A

(FB)(W)

, maximum surrounding air temperature is at 40

.

    For the model LCE-

M2A

(FB)(W)

, LCS-

02A, maximum surrounding air

 

 temperature is at 60

.

 Warranty is not valid for malfunctions that are caused by handling that does

 

 not observe the caution instructions, unauthorized modifications or natural

 

 calamities. Do not use this product for purposes other than those specified

 

 in this manual.

Caution

Panel board maximum

installable thickness : 10

1400

1100

35

φ

40

11

12

111

(13)

1-Light  158

257.5

27

φ

17.3

5-Lights 298

3-Lights 228

4-Lights 263

2-Lights 193

2-

φ

9

R20

57

27

20

17

11

32

φ

17.3

R20

30

44.5

2-

φ

4.2

(Unit : mm)

4. Dimensions

1350

LCE-

M2AFB

(

W

)

 Type

LCE-

02A

(

FB

)(

W

)

 Type / LCE-

M2A

(

W

)

 Type

[Accessory
  :L-angle dimension]

1-Light  158

5-Lights 298

3-Lights 228

4-Lights 263

2-Lights 193

950

35

φ

40

11

12

167

257.5

27

φ

17.3

1-Light  213

5-Lights 353

3-Lights 283

4-Lights 318

2-Lights 248

LCE-

□□□

A

(

FB

)

 Type

 / 

LCS-

02A Type

Hex bolt(M8)

Hex nut

(

M8

)

Mounting

bracket

Mounting hole

2-

φ

9

Flat surface

Hex nut

(

M17, P=1.5

)

Mounting hole

18

)

20

Side Mounting Installation

Flat Surface Installation

LCE-

□□□

A

(

FB

)

W Type

Panel board maximum

installable thickness : 10

(13)

1150

35

φ

40

11

1-Light 61

18

11

264

φ

17.2

5-Lights 201

4-Lights 166

3-Lights 131

2-Lights 96

[LCS-

02A Type]

1-Light  213

5-Lights 353

3-Lights 283

4-Lights 318

2-Lights 248

3-M3(P=1.5)

3-M3(P=1.5)

Summary of Contents for LCE-102AFBK

Page 1: ...LCE A LCS A 1 LED LCE A LED LCS A 02 AC DC 24V M2 AC90 250V 1 5 FB 1 5 02 AC DC 24V LCE A LCS 02A B95100295 L...

Page 2: ...11 32 17 3 R20 30 44 5 2 4 2 mm LCE 02AFB W LCE M2A W LCE M2AFB W LCS 02A 1150 35 40 11 1 61 32 264 18 17 2 5 201 4 166 3 131 2 96 L 1400 1100 35 40 11 1 158 12 111 1 158 257 5 27 17 2 5 298 3 228 4 2...

Page 3: ...AC 350mA Is 500mA Vs 35V AC LED 1 2 250V 1A LED AC DC 24V 1 27 2mA 15 2mA Is 100mA Vs 35V AC 4 5mA AC 90 250V Is 10mA Vs 35V AC 100V 12A 250V 30A 200 sec LCE 02A W LCS 02A 1A AC DC 24V AC 90 250V 1A...

Page 4: ...PNP 24V 1A 1A LCE AFB W 1A NPN PNP Vc 35V IL 0 1mA Ic 100mA LED Ic 300mA NPN PNP I O DC 24V I O DC 24V 1A DC 24V I O I O COM COM COM COM I O I O DC 24V LED A 0 39N m I O I O I O 1A 1A NPN 90 250V NPN...

Page 5: ...102AFB W 202A W 202AFB W 302A W 302AFB W 402A W 402AFB W 502A W 502AFB W 0 52kg 0 16kg 0 58kg 0 22kg 0 55kg 0 19kg 0 61kg 0 25kg 0 58kg 0 22kg 0 64kg 0 28kg 0 61kg 0 25kg 0 67kg 0 31kg 0 64kg 0 28kg...

Page 6: ...6 Ver 2 0 2014 06 01 4 4 25...

Page 7: ...ng parts such as a machine cover Warning Concerning replacement parts such as LED unit etc be sure to use those specified in this manual For safety make sure to connect an external fuse to the power s...

Page 8: ...oduct has 1mm thick waterproof packing at the bottom of the pole bracket However when complete waterproofing is not provided due to the unevenness of the installation surface apply waterproof sealant...

Page 9: ...ut the lead wire or push it into the pole or the body Install the external contact fuse on the power supply side as shown in the wiring example in order to prevent burn in case of a wiring error Enoug...

Page 10: ...r screw See 3 Part Names Caution Do not remove a LED unit forcibly or it may damage the unit Once the center screw is loose or removed the LED units and the head cover are unstable Handle carefully to...

Page 11: ...kg 0 77kg 0 41kg Power sorce wire UL1015 AWG18 Lead wire UL1007 AWG22 90 250V AC 50 60Hz LCE 02A FB W Type LCE M2A FB W Type is mass of the direct mount type type 1Light 2Lights 3Lights 4Lights 5Light...

Page 12: ...12 B95100295 14 12 NHI L...