Assemble the body ( type) or
alarm unit ( type) is
attached.
Thread the wires through the wiring hole.
Insert a mounting bolt into the installation hole.
4
Fix the Terminal Block
bracket in place with a nut.
5
Feed the wiring
through the hole
and set the pole
in place to install.
6
Attach the mounting nut from the back-side.
5
Drill Hole
(∅11mm in two places)
4
Use commercially
available bolt nuts
(M10) to fasten with.
5
7
Attach the wires
6
Use waterproof sealing if needed.
6
Use waterproof sealing if needed.
8
Point
Point
With the body ( type), or
alarm unit ( type), turn it to
the right to remove.
B
N
(→ (P.21))
For Direct mount and cable model
WJ
Point
(→ (P.21))
(→ Wiring Example (P.22))
Point
Use sealing to prevent water intrusion.
(from the mounting back-side)
If the installed environment exposes water,
etc., to the back-side of the mounting surface,
be sure to Use sealing on the mounting and
distribution holes.
When not using an attachment
angle, make a fitting hole of
∅
22-23mm.
For Steel pole and the Mount angle with the cable model
LJ
Mounting
Surface
35mm
12.2
N.m(Standard)
Recommended Torque
0.75
N.m(Standard)
Recommended Torque
30
N.m(Standard)
Recommended Torque
Threaded bore for cable gland attachment
(Effective Screw Length for M16x1.5 is 12 mm in length)
B
N
〈Notes〉 Do not pull the lead wire
connected to the Terminal
Block bracket and body (or
alarm unit).
For Direct Mount/Screwless Terminal Block model
TN
0.75
N.m(Standard)
Recommended Torque
Installation Template(→P.29)
5
4
What
voltage?
DC?
AC?
Not used
9±1mm
If wiring is extended beyond its factory length,
a relevance in the length of the wire and wire
gauge that will cause a voltage drop.
Caution
■About Mode Switch-over
When entering the "Mode Change", the operating mode can be changed to the "Smart Mode". In the "Smart Mode", various
lighting and alarm patterns can be arranged. Visit our company's homepage (http://www.patlite.com) for further details.
The wiring example indicates how to connect to external contacts for every classification.
If there are any special applications that require asking questions concerning this product, feel free to contact your
PATLITE Sales Representative.
Wiring Example Index
LED Tier 1 / Input 1
/ ①
Red
Function Name
[Signal Tower Mode] / [Smart Mode]
Lead Wire Color
(Cable Specification)
PIN No.
( Direct Mount/
Screwless Terminal
Block Spec.)
→Refer to the figure on
the right "Screwless Terminal
Block connector PIN
arrangement."
TN
Screwless Terminal Block Connector PIN Arrangement
( Direct Mount/ Screwless Terminal Block Specifications)
TN
■Recommended lead wire specifications
■Alarm Sound Pattern (Factory Default)
・Temperature rating should be above 75℃, and the conductor material
should be of copper wire.
UL1007 / UL1430
Wire Type
Alarm1
Alarm2
Alarm 1 and Alarm 2 Entered Simultaneously
Alarm Sound No.2
Alarm Sound No.9
0.5〜1.5mm
2
Wire Gauge (Solid Wire)
AWG20〜16
Wire Gauge (Frayed Wire)
1
Red
2
Orange
3
Green
4
Blue
5
White
6
Gray
7
Black
8
Yellow
9
Gray
10
Black
11
<Note> The lead wire color does not
indicate the LED luminescence color.
Caution
Warning
Do not
pull
the lead wire or
push
it inside the body.
Strip 9±1mm
of wire insulation
from the wire to insert it in the
Screwless Terminal Block. If the
wire is shorter than 9mm, a poor
connection may occur, and if the
wire is too long, there is a
possibility of electric shock or
short-circuiting.
( Direct Mount/ Screwless
Terminal Block Specifications)
It is not necessary to connect to an
external lead for tiers not used.
When an extra lead is not connected, it
should be individually insulated
with
electrical tape or something similar.
Ensure
the proper working
voltage
is used and that
direct
current or alternating current
is
properly applied.
Failure to comply may result in
combustion.
Be sure
the power is disconnected
before replacement or repair.
Failure to comply will result in
damage due to
short-circuiting
.
TN
TN
Wire the product so that
the lead
wire does not protrude from the
Screwless Terminal Block
.
Failure to comply may result in
short-circuiting.
( Direct Mount/ Screwless
Terminal Block Specifications)
22
Purple
LED1・Input1
LED2・Input2
LED3・Input3
LED4・Input4
LED5・Input5
Alarm1・Input6
Alarm2・Input7
Power Wire
Flashing/Pulse Enable Common
Power Line (Signal-line Side)
Mode Change
Alarm Sound No.1
Wiring Example
Wiring
5
21