Installer’s Guide

 

same box. 

Attach the conduit runs to the enclosure using standard 

connectors (not supplied).   The backbox should be clean 
and free of obstructions or foreign materials.  Inside, there 
should be  one  Cat5  wire  with a female RJ45  punchdown 
connector (if necessary, install the mini-jack included) and 
one  or  two  cables  for  the  DMX  connections,  ending  in 
bare  wires.    Identify  which  cable  is  for  DMX  Universe  A 
and which is for DMX Universe B. 

Retrieve  the  faceplate  from  the  storage  container.    In-

spect  it  for  damage  and  to  ensure  the  printed  circuit 
boards are securely fastened. 

Using  the  XLR  pin-out  chart  at  the  start  of  this  guide, 

attach the cable for DMX Universe A to the terminal block 
marked DMX Port A. Repeat,  if necessary, for DMX  Port 
B.  If Cat5 cable is being used to complete the DMX run, 
use the Cat5 pin-out guide instead. 

Using  the  male-to-male  jumper,  connect  the  female 

RJ45 connector to the connector on the back of the circuit 
board of the node.   

If  local  power  is  required,  see  the  note  at  end  of  this 

guide. 

Gently  position  the  faceplate  on  the  backbox  until  the 

screw  holes  line  up,  while  taking  care  that  no  wiring  is 
pinched, excessively bent or stressed inside the box.  Us-
ing the original two screws, reattach the faceplate.  Do not 
over tighten. 

The node is ready to be powered up. 

PATHPORT UNO (6101SS/BL, 6102SS/BL) 

Disconnect  all  power  before  proceeding  with  installa-

tion.    

Pathport  Uno  single-port  nodes  are 

designed  to  be  installed  in  standard 
masonry deep backboxes (ears in) for 
flush  mounting,  or  deep  (minimum 
58mm  or  2.25”)  surface  mount  back-
boxes.   

If the node has been pre-configured, 

check  the  temporary  label  to  ensure 
the  node  is  being  installed  in  the  cor-
rect location. 

Uno  nodes  can  be  permanently  set 

to a specific DMX universe, 1 through 
4,  by  use  of  a  jumper  on  the  back 
edge of the circuit board.  If the system designer has not 
given  specific  instructions  about  the  setting,  then  leave 
the jumper in the NET position.  

Each  Uno  node  ships  with  additional  serial  number 

stickers.    Do  not  lose  these  stickers.    Because  Unos  do 
not have a faceplate screen, tracking serial numbers and 
their locations is necessary to configure the system.  Los-
ing track of this information  will  add considerable time to 
commissioning. 

As each node is installed, remove one of the additional 

serial  number  stickers  and  place  it  on  the  Installation 
Record  Sheet  included  with  each  Uno.    Write  down  the 
location,  jumper  settings  and  any  other  comments.    A 
second  sticker  can  be  placed  on  the  face  of  the  Uno  for 

identification  during  commissioning.    This  sticker  can  be 
easily removed and discarded when no longer needed. 

Once this information is recorded, check the backbox for 

obstructions  or  foreign  material.    The  backbox  should  be 
clean  and  empty  of  debris.    Inspect  the  Uno  and  make 
sure  all  components  are  securely  fastened  and  that  the 
printed circuit boards are intact. 

If  the  back  backbox  contains  an  RJ45  female  punch-

down connector, use a male-to-male jumper to connect it 
to the node.  Otherwise, plug the male RJ45 pigtail directly 
into  the  connector  on  the  back  of  the  node.    Attach  the 
green ground wire to the ground screw in the backbox. 

Gently  insert  the  Uno  straight  into  the  backbox  and 

screw  it  into  place  with  the  long  mounting  screws  provid-
ed.  Place the cover plate over the installed Uno and use 
the  two  short  screws  to  fasten  the  cover  plate.    Do  not 
over-tighten these screws. 

The Uno is ready to be powered up. 

Disconnect all power before proceeding.  
Each Pathport eDIN ships with additional serial number 

stickers.    Do  not  lose  these  stickers.    Because  Pathport 
eDINS  are  intended  for  installation  within  enclosures, 
maintaining  a  log  of  serial  numbers  and  their  locations  is 
necessary  to  configure  the  system.    Losing  track  of  this 
information will add considerable time to commissioning. 

As each  node is  installed,  remove one  of the additional 

stickers  and  place  it  on  the  Installation  Record  Sheet  in-
cluded with each Pathport eDIN.  Write down the location, 
jumper settings and any other relevant comments.  

A  second  serial  number  sticker  may  be  placed  on  the 

exterior cover of the enclosure as a further identifying aid 
during commissioning.  This sticker can easily be removed 
and discarded when no longer needed. 

Securely  mount  DIN  rail  (if  not  already  installed  in  the 

enclosure).  Hook the upper slots on the back of the plas-
tic  extrusion  to  the  DIN  rail  and  then  gently  but  firmly 
press on the bottom front corners of the extrusion to snap 
the  module  onto  the  rail.    Do  NOT  press  directly  on  the 
PCB card itself. 

Attach  the  DMX  wiring  to  the  terminal  strip  output  con-

nector(s).  If the Pathport eDIN is using an auxiliary power 
supply, connect the terminal strip. Observe DC polarity. 

Attach the network cable to the RJ45 connector marked 

Ethernet.  The node is ready to be powered up. Both aux-
iliary  power  and  PoE  can  be  connected  simultaneously 
without damaging the Pathport eDIN.   

Pathport 1011 nodes may be set permanently to a spe-

cific  DMX  universe,  1  through  4,  by  use  of  a  dip  switch 
block on the circuit board.  If the system designer has not 
given  specific  instructions  about  this  setting,  all  switches 
should be left in the OFF position. 