To configure, first press the ▲ or ▼ buttons to select the 

desired function, indicated by the LED next to ADDRESS, 

MODE, UTIL, or TEST. Once selected, press and hold 

the ENTER button until three dots appear across the 

bottom of the display. The card is now in EDIT mode.
When  done  editing  a  parameter,  press  ENTER.  The  dots  will 

disappear, the new  value will be saved and the unit will be ready 

for operation.

Once in MODE edit, choose from the following:

• 

MODE 1: HTP (Highest Takes Precedence)

The highest level present on the analog input OR the DMX512 

input for a given control channel is the level that will be present 

on the DMX512 output. 

• 

MODE 2: Analog Takes Precedence (Analog Priority)

If the analog input level for a given channel is 4% or greater (8-bit 

value greater than 10), the DMX512 output for that channel will 

reflect the analog input value, and the corresponding DMX512 

input value will be ignored. If the analog input value for a given 

channel is less than 4% (8-bit value less than 11), the DMX input 

level will determine the output level for that channel.

• 

MODE 3: DMX Takes Precedence (DMX Priority)

Whenever the DMX512 input data stream is present at the DMX 

IN, the DMX input levels will determine the DMX512 output levels 

of all channels, and all analog input levels will be ignored.

• 

MODE 4: Contact Closure Input

Whenever a given contact input is closed for a given channel 

(input shorted to COM), the DMX512 output for that channel 

will be 100% (8-bit value 255). When the contact input is open, 

the output for that channel will be determined by the DMX input 

level, if present. 

• 

MODE 5: Preset Recall

When a given contact input is closed momentarily (input shorted 

to COM), the corresponding recorded preset will be activated on 

a crossfade time of 5 seconds. All 512 possible DMX channels 

are stored for each preset. A recalled preset will be HTP (highest-

takes-precedence) merged, on a channel-by-channel basis, with 

any DMX input present on the DMX IN port. 

• 

MODE 6: DMX Takes Precedence over Preset Recall

Whenever DMX512 is present at the DMX IN, the DMX input 

levels will determine the DMX512 output levels, and all recalled 

presets will be ignored.

Once in ADDRESS edit mode, press ▲ or ▼ to change the start 

address to the desired value. Inputs will be numbered sequentially 

starting from this DMX slot. Press ENTER to save the address. Valid 

addresses range from 1 to 512.

Once in TEST mode, use the ▲ or ▼ buttons to select an input from 

1 to 24. Press ENTER again to display the selected input’s present 

level (from 0 to 100%) when operating in analog input mode.
When in contact input mode, the display will show the state of the 

selected input (0 or 100).
TEST is operating mode dependent and will ignore DMX control 

while in edit mode.

Press the ▲ or ▼ buttons until UTIL is reached and the screen reads 

REC. Press ENTER until the dots appear. Use the ▲ or ▼ buttons 

to select the desired preset number. Connect incoming DMX to the 

DMX IN terminal and verify the look is correct.
Press ENTER to capture and store the incoming DMX as a preset in 

the chosen location. Repeat for each additional preset to be stored.

Press the ▲ button while turning power on to enter self-test mode. 

All LEDs will flash sequentially. The display will cycle 0 through 9, 

then show the serial number and firmware version. Cycle power to 

end self-test.

CONFIGURATION

SET OPERATING MODE

SET DMX ADDRESS

TEST MODE

PRESET RECORDING

SELF-TEST

UTIL has two settings: the first shows the input number associated 

with the current active preset. The second accesses preset recording 

- see PRESET RECORDING below.

UTIL MODE

DMX rules require the last device on a DMX line to be 

terminated with a 120Ω resistor between pins 2 and 3 

to prevent signal reflection. If there is no connection to 

the DMX THRU terminals, the DMX Terminate switch 

should be ON. 
If  there  are  other  devices  connected  to  the  DMX 

THRU terminal, the DMX Terminate switch should be 

OFF and termination be applied to the final device in the daisy-chain.

DMX TERMINATE

The  1006  is  fully  compliant  with  ANSI  E1.20  Remote  Device 

Management  as  a  responder  device.  An  RDM  Controller  can 

discover and set the card’s DMX start address, firmware version 

and operating mode. The 1006 will report input DC voltages as a 

sensor property.

With Pathscape software, the user can upgrade the firmware in the 

field.

E1.20 RDM RESPONDER FEATURES