POWER IN
Blue
. Steady glow indicates power supply OK;
off indicates no power.
PROCESSOR
Green
. Steady glow indicates processor is OK;
off when POWER IN is lit indicates processor
failure.
DMX INPUT
Amber
. Steady glow indicates port latched to ac
-
tive DMX source; off indicates no signal present.
RELAY
Red
. Steady glow indicates relay is energized.
Flickers for momentary action.
FUNCTION
Amber
. Indicates the function associated with
the numeric display.
Model 1003 12-Relay
Contact Closure
Manual
1003-300-REV1
04/04/19
TM
The Pathway eDIN Contact Closure provides twelve
DMX-controlled, form-C relay closures for low voltage
power or signal switching.
RDM discoverable and configurable, with a DIN-rail mount
that makes installation fast and easy.
The 1003 features terminal strips that can be removed from the
card to facilitate easy wiring installation or replacement. Make the
following connections,
WITH THE POWER TURNED OFF.
POWER
The module will run on a range from 9 to 30 VDC at a maximum
of 6 Watts. Observe the correct polarity when connecting the V+
and V-. A second set of terminals are provided on the connector to
daisy-chain power to other eDIN modules. The EARTH GROUND
terminal must be connected to the enclosure’s chassis or electrical
ground terminal to ensure EMC compliance.
DMX512
DMX connections consist of a shield and data pair.
Connect the DATA+ and DATA– wires to D1+ and D1-
respectively for each of DMX IN and DMX THRU.
Observe the same polarity convention throughout the system.
Connect the cable shield to the SHLD COM terminal.
DMX THRU may be daisy-chained to the DMX IN of other eDIN
modules.
DMX PRESENT RELAY CLOSURE
Starting with firmware 1.5.5, the J13 DMX present relay closure is
supported. Wire RCOM to RNO or RNC for normally-open or nor
-
mally-closed, as desired.
CONTACT OUTPUTS
The 1003 can be thought of as twelve DMX controllable switch clo
-
sures. As switches, they need two connections each, as the switches
OVERVIEW
CONNECTIONS
STATUS INDICATORS
provide no voltage or current on their own. One connection is to the
supply and one to the load. Each relay has three sets of contacts;
normally-open (NO), normally-closed (NC), and common (C).
Generally, the normally-open contacts are used; providing an open
switch that closes when the relay is energized. Normally-closed con
-
tacts operate in the opposite manner, providing a closed switch that
opens when the relay is energized.
All common terminals are independent of one another.
RCOM
RNC
NO1
V+
V-
V+
GROUND EARTH
V-
NC
NC
D1+
COM SHLD
D1-
NC
NC
D1+
COM SHLD
D1-
C1
NC1
NO2
C2
NC2
NO3
C3
NC3
NO4
C4
NC4
NO5
C5
NC5
NO6
C6
NC6
NO7
C7
NC7
NO8
C8
NC8
NO9
C9
NC9
NO10
C10
NC10
NO11
C11
NC11
NO12
C12
NC12
ON
OFF
POWER IN
PROCESSOR
DMX INPUT
ISO 5V
POWER IN
9-30VDC
6 Watts Max.
ENTER
RELAY3
RELAY2
RELAY1
RELAY4
RELAY5
RELAY6
RELAY7
RELAY8
RELAY9
RELAY10
RELAY11
RELAY12
RNO
eDIN 12 CHANNEL
CONTACT CLOSURE
OUTPUT
Pathway Connectivity
ADDRESS
MODE
UTIL
TEST
NORMALLY OPEN OR CLOSED
RELAY CONTACT OUTPUTS
2A @ 30VDC MAX
(12 TOTAL)
END OF LINE
TERMINATION SWITCH
DMX IN FROM
CONTROL SYSTEM
DMX THRU TO
OTHER eDIN MODULES
DMX SIGNAL
PRESENT RELAY
STATUS LEDs
MENU
FUNCTION LEDs
POWER IN:
9-30VDC, 5W SUPPLY REQUIRED.
USE #1001-100-24-DIN
POWER SUPPLY OR EQUAL.
CONNECT EARTH GROUND TO PROTECT
DMX INPUT FROM RF INTERFERENCE
CARRIED ON CABLE SHIELD.
LED NUMERIC
DISPLAY
PROGRAM
PUSHBUTTONS