5
WARNING
Burn and scald hazard. Failure to install mixing
valve will result in hot water scalding hazard.
Install mixing valve per manufacturer instructions.
!
Hydronic system is supplied with
•
freewatt communicating
thermostat. Utilize thermostat on single “Smart Zone” only.
Select “Smart Zone” as zone with largest heating demand
(not domestic hot water zone) typically the largest space
heating zone on fi rst fl oor of two story home. freewatt
PLUS System will produce best electric power generation
benefi t if Smart Zone represents at least 25% of total home
heating load. Consider combining zones to achieve desired
heat load for Smart Zone if there is no single large zone in
existing distribution system, but many small zones.
freewatt
•
communicating thermostat is directly wired to
freewatt Control Module circuit board. Additional fi ve
zones, with compatible conventional heating thermostats
(new or existing) may be connected directly to freewatt
Control Module circuit board. If more than compatible six
zones (including priority domestic hot water and Smart
Zone) are needed freewatt PLUS System can be
expanded to include additional heating zones. Additional
ECR zone controls may be required.
Hydronic
•
freewatt PLUS System installation may be
phased. Install freewatt PLUS Boiler and Control Module
in required piping confi guration as shown in Section 17,
leaving installation, commissioning, and operation of MCHP
to later date (cap off piping connections to MCHP), if need
to supply heat to building quickly as possible. freewatt
PLUS boiler will provide suffi cient heating capacity to meet
normal loads if MCHP unit is not available for operation.
MCHP unit will provide signifi cant portion of annual
•
heating energy needed in home, MCHP unit alone
cannot be expected to meet all desired comfort and/or
freeze protection needs. Maintaining operation status of
freewatt Boiler as part of freewatt PLUS System is
essential to meeting all comfort and/or freeze protection
needs.
“CHP MODE” switch OFF position conveniently
•
separates and maintains boiler heating function while
disabling operation of MCHP unit and generation of
electric power. This is Bypass Mode of operation.
Full heating operation of hydronic
•
freewatt PLUS System
is not dependent on maintaining working connection to
Internet. Lack of internet connection will prevent remote
communication with system by homeowner or service
provider.
2- INTRODUCTION
Installation of UL and ULC recognized CO detectors with
•
audible alarms (not supplied with system) are required
part of freewatt PLUS installation. freewatt PLUS
Exhaust Gas Detection System included part of freewatt
PLUS System does not provide audible alarm for protec-
tion of building inhabitants from potentially dangerous high
levels of carbon monoxide. Install both Exhaust Gas Detec-
tion System and separate, independent UL recognized CO
Detectors.
Installation of two different outdoor temperature sensors is
•
required for proper operation of hydronic freewatt PLUS
System, both are supplied. One (Honeywell) connects
directly to boiler and other (Tekmar) to freewatt Control
Module.
hydronic
•
freewatt PLUS System will generate heat &
electric power during power outage if installed and commis-
sioned per Installation, Operation, and Maintenance Manual.
Heating system must be connected to APC UTS.
Installation, setup, commissioning and maintenance of
•
freewatt PLUS System requires use of freewatt
PLUS MINT software tool loaded on laptop computer run-
ning Windows XP or Vista with working serial connection.
Call
•
freewatt PLUS Technical Support Line for free-
watt PLUS System installations above 3,300 feet and for
additional information.
Heat rejection kit (sold separately) required for instal-
•
lation.
Water cooled heat rejection kit used when there
•
is uninterruptable supply of water during power
outage. Kit ties into main water supply line and
discharges water to appropriate drain.
Air cooled heat rejection kit used when there is
•
not uninterruptable supply of water during outage
(houses with well pumps). Air cooled heat rejection
system is vertically arranged side discharge fan-coil
unit with closed coolant loop designed for outdoor
installation.
Zone Valves with their own 24 VAC power supply may
•
be used on zones 3-6. Refer to Electrical Wiring and
Connections section for detailed information on use of
steering relays in freewatt control module.
Summary of Contents for freewatt HDJ
Page 43: ...43 15 DETAILED SEQUENCE OF OPERATION...
Page 44: ...44 15 DETAILED SEQUENCE OF OPERATION...
Page 57: ...57 17 5 HDJ 240 VAC Wiring Only 17 PIPING AND WIRING SCHEMATICS...
Page 58: ...58 17 6 HDJ 120 VAC Wiring Only 17 PIPING AND WIRING SCHEMATICS...
Page 59: ...59 17 7 HDJ 120 VAC Wiring Control Module Zone Pumps 17 PIPING AND WIRING SCHEMATICS...
Page 60: ...60 17 8 HDJ 120 VAC Wiring Control Module Zone Valves 17 PIPING AND WIRING SCHEMATICS...
Page 61: ...61 17 9 HDJ 120 VAC Wiring Control Module Hydro Air 17 PIPING AND WIRING SCHEMATICS...
Page 62: ...62 17 10 HDJ Low Voltage Wiring Only 17 PIPING AND WIRING SCHEMATICS...
Page 66: ...66 17 PIPING AND WIRING SCHEMATICS 17 13 HDJ Low Voltage Only Wiring Control Module Hydro Air...
Page 67: ...67 17 PIPING AND WIRING SCHEMATICS 17 14 MCHP Low Voltage Wiring...