Passtech AP300 User Manual Download Page 1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Passtech Co., Ltd.   

 

 

Copyright 

  2017 Passtech Inc. All rights reserved. You are strictly prohibited to copy, disclose, distribute, 

or  use  this  document  in  part  or  as  a  whole  for  any  purposes  other  than  those  for  which  this  document  is 

disclosed. This document is copyrighted and contains confidential information and other intellectual property 

rights  of  Passtech  Inc.  Any  unauthorized  use,  copy,  disclosure  or  distribution  constitutes  infringement  of 

Passtech

’s intellectual property r

ights. 

USER GUIDE 

ACCESS POINT 

(AP300_Ethernet Setting) 

Summary of Contents for AP300

Page 1: ...for any purposes other than those for which this document is disclosed This document is copyrighted and contains confidential information and other intellectual property rights of Passtech Inc Any un...

Page 2: ...on Passtech assumes no liability and is not responsible for infringement of patents and or any other intellectual or industrial property rights of third parties which may result from assistance provid...

Page 3: ...s Preparation 4 1 1 SETUP Components 4 1 2 Setting Diagram 4 2 AP Setting 5 2 1 SERVER AP300 Communication Diagram 5 2 2 AP Setting 5 3 Server Setting 11 3 1 Server pre setting DB Connection 11 3 2 Se...

Page 4: ...AP300 ACCESS POINT User Manual Version 1 0 4 http www esmartlock com 1 Components Preparation 1 1 SETUP Components 1 2 Setting Diagram...

Page 5: ...www esmartlock com 2 AP Setting 2 1 SERVER AP300 Communication Diagram 2 2 AP Setting Before creating AP account please check PC IP and TCP IP first by running Command Prompt and inputting ipconfig c...

Page 6: ...AP300 ACCESS POINT User Manual Version 1 0 6 http www esmartlock com Click Search button Mac address and IP of connected AP200 will be shown on AP List...

Page 7: ...ned to this AP Local Port Assign the port number on your own Default 5000 Subnet Input the value Subnet Mask checked in Command Prompt Gateway Input the value Default Gateway checked in Command Prompt...

Page 8: ...http www esmartlock com Select RF Channel and then click Conn button and check the message Connected OK from the message box If it is connected well WRITE and READ buttons will be activated Click REA...

Page 9: ...RF Channels you would like to connect 11 25 BUILD Building number 1 50 FLOOR Floor number 1 99 ROOMS Room numbers 1 999 Click WRITE button to save the information of the selected AP and check the mes...

Page 10: ...Building number which you set in AP Settings Group ID Input Group number which you set in AP Settings Lock Start Input Starting Room number of the lock which you set in AP Settings Lock End Input Endi...

Page 11: ...Change the environmental files for DB connection before executing the communication Server Program Run ConfigSetting exe in the folder where the program is installed Input the Connect information to c...

Page 12: ...12 http www esmartlock com Click Config and put information as below Put information same as the one you put for config setting above Local Server IP will be your PC IP Ex 192 168 0 52 1433 1 2 1 2 SQ...

Page 13: ...AP300 ACCESS POINT User Manual Version 1 0 13 http www esmartlock com 3 2 Server Connection Run the Server Program PTHMS_Server exe The program is started as shown below...

Page 14: ...screen will appear and you have to enter the DB connection value as shown below Refer to contents 4 1 The Server Account is the part which sets the communication port to receive or send data form the...

Page 15: ...he server account is created successfully you will see a screen below This is the part where you can register the AP information that connects to Server which you have set from AP Management Program A...

Page 16: ...as AP Client AP Name must be same as AP Client Channel number must be same as AP Client AP IP Address same IP as Local IP in AP Client Lock Info Building Floor Start End Room must be same as AP Client...

Page 17: ...up and Shutdown 1 Server Program Startup Run Server Program PTHMS_Server exe When the program is running a Tray Icon is created as below 2 Program Shutdown To exit the program right click the Server I...

Page 18: ...is using in Hotel Office and any place which is without residential area Item Detail Material ABS Communication 2 4Ghz Zigbee ONLINE LOCK COMM TCP IP SERVER COMM Security AES128 Power Supply DC 12V AD...

Page 19: ...equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense FCC Part 15 21 statement Any changes or...