Pass INT-60 Owner'S Manual Download Page 8

8

Maintenance:

Leave it on or turn it off: 

The product is designed to be left on all the time. The 

exception to this might be a case where the preamp will not be used for an extended 
time - in that case it can be turn off.

Cleaning: 

The fi nish can be damaged by harsh cleaners and abrasive cloths. We 

fi nd a damp soft cloth works best. You can also use a mild solution of windex or white 
vinegar but be careful to avoid the acrylic window. The acrylic window should only 
be cleaned using “plastic cleaner & polish”.

Remote batteries:

 The two AAA batteries should be replaced every six months at 

least. The batteries are located under the remote back. This is held in place with four 
4-40 phillips fl at head screws. Please note the polarity of the batteries, putting them in 
wrong could cause damage.

Replacing the fuse:

 The fuse should only be replace with the same type and size as 

indicated on the rear. Audio Specialty FUSE: NOTE: The “Overload” and “Time Delay 
characteristics” will differ slightly (due to the different metallurgy of the fuse elements) 
between commercial grade and audio grade fuses. We can’t guarantee that 
your audiophile grade fuse, won’t blow at a different in-rush current threshold, than 
your stock commercial fuse. Use of other than approved fuses, may invalidate your 
product warranty and result in product damage.

INT-60 Specs: 

Inputs:  

 

 

 

 

Four(4) 2 XLR/RCA + 2 RCA

Gain    

 

 

 

 

30/36dB

Output power 

 

 

 

60 Watts rms @ 8 ohms

 

 

 

 

 

 

120 Watts rms @ 4 ohms

Distortion: 

 

 

 

 

1% @ 60 Watts, 8 ohms, 1 KHz

Frequency response:  

 

 

-6 dB @ 80 KHz

Residual Noise  

 

 

 

< 250 uV output, unweighted 20 to 20 KHz

Damping Factor:  

 

 

 

150

Input Impedance:   

 

 

45 Kohm

Idle Power draw: 

 

 

 

~3 Amps @ 120 VAC

Dimensions:    

 

 

 

19”w x 21.25”d x 7.6”h

Weight: 

 

 

 

 

93 lbs

How to replace the fuse:

Summary of Contents for INT-60

Page 1: ...1 pass INT 60 Owner s Manual ...

Page 2: ...stroy equip ment Ventilation Power amplifiers run warm but you should be able to place your hands on them without discomfort You must allow for this heat in installation by providing for free air circula tion around the product Leave a minimum of 6 of space around the amplifier The ventila tion should not be impeded by covering the ventilation openings with items such as newspa pers table cloths cur...

Page 3: ...ame efficient toroidal design in the power supply with both an electrostatic and Mu metal shield along with vacuum impregnating and epoxy fill This gives us a very quiet transformer both electrically and mechanically The power supply circuitry itself is also lower noise and has additional filtering a little more complicated but worth it The INT 60 uses a simplified preamp and volume control circuit th...

Page 4: ...have the blue LED in the center of the meter on Push the power button on the faceplate a few times The amp should cycle on and off display and meter lights will come on and go off Turn the amp off from the faceplate Now you should be ready to connect your sources and speakers Quick Connections Connect your sources to the inputs There are four inputs two with XLR and RCA and two with RCA only The X...

Page 5: ...les between Standby and On The four Input Select switches select the active input 1 through 4 directly The right most button on the front panel is Mute Pressing this button toggles between mute on and mute off Mute on removes signal from the output of the preamp The electronic volume control allows 63 dB range and is driven by a micro controller that reads the optical encoder serving as a front pa...

Page 6: ... not used with the INT 60 This is used on other Pass products and has no effect on this product Tape is not used with the INT 60 This is used on other Pass products and has no effect on this product Pass Thru is not used with the INT 60 This is used on other Pass products and has no effect on this product Display is not used with the INT 60 This is used on other Pass products and has no effect on ...

Page 7: ...7 ...

Page 8: ...ing them in wrong could cause damage Replacing the fuse The fuse should only be replace with the same type and size as indicated on the rear Audio Specialty FUSE NOTE The Overload and Time Delay characteristics will differ slightly due to the different metallurgy of the fuse elements between commercial grade and audio grade fuses We can t guarantee that your audiophile grade fuse won t blow at a d...

Page 9: ...factory or shipping product to the factory for repair Non North American product must be returned to the country of origin for warranty service Foreign distributors are only required to offer warranty service on Pass Laboratories product that they have imported verifiable by serial number Please note Conditions of warranty service and customer rights for product purchased outside the United States ...

Page 10: ...10 pass Pass Laboratories Inc 13395 New Airport Rd Suite G Auburn CA 95602 530 878 5350 passlabs com ...