Pass INT-250 Owner'S Manual Download Page 6

6

7

Warranty:

Please check with the factory authorized distributor in the country where you are purchasing
this product for speci

fi

c warranty information.

All Pass Laboratories products purchased new from an authorized Pass Laboratories dealer in
North America are covered by a transferable, limited 3-year warranty. This warranty includes
all parts and labor charges incurred at the factory or factory speci

fi

ed repair facility, exclusive

of any subsequent or consequential damages. Damage due to physical abuse is speci

fi

cally

excluded under this warranty.

For this warranty to apply the customer is responsible for returning the product unmodi

fi

ed to

the factory within the speci

fi

ed warranty period. The customer assumes all responsibility for

shipping and insurance to and from the factory or a factory speci

fi

ed repair facility. The

conditions and stipulations of this Pass Laboratories warranty only applies to units originally
sold new through an authorized dealer. Warranty on factory repair is 60 days and covers only
the scope of the original repair.

Non-North America customers should consult with their original Pass Labs dealer or
distributor for warranty repair instruction prior to contacting the factory or shipping product
to the factory for repair.

Non-North American product must be returned to the country of origin for warranty service.
Foreign distributors are only required to offer warranty service on Pass Laboratories product
that they have imported, veri

fi

able by serial number.

Please note: Conditions of warranty service and customer rights for product purchased
outside the United States may vary depending upon the distributor and local laws. Please check
with your local distributor for speci

fi

c rights and details.

Any modi

fi

cations to Pass Laboratories products that have not received written factory

approval nullify all claims and void all provisions of the warranty and liability by the maker or
authorized distributor. Should a modi

fi

ed product be returned to the factory for repair the

owner will be required to pay all necessary charges for the repair in addition to those charges
required to return the product to it's original con

fi

guration.

In the case of safety issues, no product shall be returned to the customer without those safety
issues being corrected to the most recent accepted standards.

Removal or alteration of original Pass Labs serial numbers voids the factory warranty. Product
with altered or missing serial numbers will be suspect as counterfeit or stolen product.

Pass Laboratories will not repair or in any way indemnify any counterfeit or cloned product.

Pass Laboratories does not offer products in voltages intended for international markets
either to authorized Pass Labs dealers or to third parties located in the United States or
Canada.

Pass Laboratories, 13395 New Airport Rd., Suite G., Auburn,

95602

CA

Phone: 530.878.5350, Fax: 530.878.5358, Web: www.passlabs.com

Preliminary Specs:

INT-250

Gain

29/35 dB

Volume control (1dB steps)

63dB

Remote

yes

Inputs

4

Outputs

2

Power Output /ch (8 ohm

250 Watts

Power Output /ch (4 ohm)

500 Watts

Type

Class AB

Frequency Response

-6dB @ 80     z

KH

Input Impedance (Kohms)

45

Distortion, (1      z, full power)

1%

KH

Damping Factor

150

Slew Rate (V/uS)

50

Output Noise (uV)

<250

Input

(dB)

-60

CMRR

DC Offset (V)

0.05

Leaves Class A at pk Watts:

15

Power Consumption (W)

375

Temperature (deg C.)

53

Dimensions (W x D x H)

19 x 21.25 x 9.06

Weight (

105

LBS

Ship Weight (

)

125

LBS

Summary of Contents for INT-250

Page 1: ...PASS INT 250 250W Integrated Amp AB ...

Page 2: ...r supply cords should be routed so that they are not likely to be walked on abraded or pinched by items placed on or against them paying particular attention to cords where they enter plugs or exit from a device Never under any circumstance insert a cut or damaged power cord into a mains power socket Power and Signal Cables should never be connected disconnected with equipment powered up Failure t...

Page 3: ...mes LED Theamp shouldcycleon and off displayand meterlightswillcomeon and go off Turn the amp off from the faceplate Now you should be ready to connect your sources and speakers QuickConnections Connect your sources to the inputs There are four inputs two with and and two XLR RCA with only The and inputs on 1 and 2 are connected so use RCA XLR RCA INPUT INPUT XLR RCA INPUT RCA XLR or but not both ...

Page 4: ...or 9 Mute button LED 1 Right Speaker Connection 2 Preamp outputs 3 Power Switch RCA XLR AC 4 Mains Inlet 6 Preamp inputs AC RCA XLR 7 Signal Ground 8 Left Speaker Connection Preamp Output L R R L Preamp Inputs 1 2 3 4 Right Right Left Left Left Right Left Right Jumper must be used with single ended input No user serviceable parts inside 3 1 2 Signal Gnd Pass Laboratories Auburn CA 95602 AC Mains 2...

Page 5: ...250 draws less than 0 5 watts Front Display Meter The display show volume level in one dB steps from 0 to 63 The meter operates LED slightly different from our amplifiers in that this meter doesn t show bias but output voltage Input selection The inputs can be selected by the four buttons on the face plate or the input buttons 1 4 on the remote Volume control The volume level can be set by using t...

Page 6: ...ican product must be returned to the country of origin for warranty service Foreign distributors are only required to offer warranty service on Pass Laboratories product thattheyhaveimported verifiable byserialnumber Please note Conditions of warranty service and customer rights for product purchased outsidetheUnitedStatesmayvarydepending upon thedistributorand local laws Pleasecheck withyourlocal...

Page 7: ...Outputs 2 Power Output ch 8 ohm 250 Watts Power Output ch 4 ohm 500 Watts Type Class AB Frequency Response 6dB 80 z KH Input Impedance Kohms 45 Distortion 1 z full power 1 KH Damping Factor 150 Slew Rate V uS 50 Output Noise uV 250 Input dB 60 CMRR DC Offset V 0 05 Leaves Class A at pk Watts 15 Power Consumption W 375 Temperature deg C 53 Dimensions W x D x H 19 x 21 25 x 9 06 Weight 105 LBS Ship ...

Reviews: