background image

4

XP-25 Owner’s Manual

Before you sit back and listen, take time to read and understand 

cartridge loading.  When you find the desired setting, please record 

that setting so that you can come back to it in the future.  For your 

convenience we left space at the end of this manual for just these 

sorts of details.

TECHNICAL DETAILS:

As previously indicated the XP-25 is a twin chassis design.  One 

chassis holds the fully filtered and regulated power supplies and 

the second chassis houses the analog gain circuits, input switching, 

loading and all those details and features normally associated with a 

reference RIAA phono stage.

The two chassis are interconnected with a shielded and filtered Din-

25 cable.  This Din-25 cable only carries power, never analog signal.   

 As far as this product is concerned you may use either Din-25 power 

connector on the power supply chassis to link-up with the XP-25 

control module.  Both power connectors are identical and provide 

identical performance from the phono-stage. The second Din-25 

connector is capable of powering either another XP-25 phono-stage 

or a Pass Laboratories XP-20 pre-amplifier without degradation of 

measured or perceived performance.

Consumers frequently ask us if they may substitute a Din-25 cable 

of their choice for the one Pass Laboratories supplies.  The answer is 

yes, provided that cable carries all the necessary legal approvals.  For 

those of you so inclined, please pick a shielded and filtered cable so 

as to not degrade the full measure of performance your new XP25 is 

capable of producing.  

Never attach or detach the Din_25 cable with the power supply, 

powered up from the wall.  Always unplug your XP-25 from line 

voltage prior to attaching or removing the Din 25 cable.

The rear of the power supply chassis has a standard IEC 320 power 

inlet module a fuse holder and twin Din-25 power connectors.  As 

with the Din-25 cable, the user is free to substitute a suitable IEC 

power cord of their choice.  This product accepts any cordset with 

an IEC 60320 C13 connector or equivalent.  Be aware however that 

the XP-25 power supply is not particularly sensitive to differences in 

properly terminated power cords.

If you substitute an aftermarket power cord you need to be aware 

of the following.  The ground pin on the power cord provides this 

Summary of Contents for XP-25

Page 1: ...1 XP 25 Owner s Manual pass TM XP 25 Owner s Manual Feb 4 2010 ...

Page 2: ... sound with dramatic detail and spectacular layering Those listeners familiar with Pass Laboratories previous phono pre amps will be struck by the clear delineation of bass notes in the XP 25 and the greater sense of music in a real physical space Like some great musicians we get requests You spoke and we listened so that you can listen better Now the XP 25 a product designed at the intersections ...

Page 3: ... had clearly taken a page from the automotiveandmotorcycleracingcognoscenti whoseengineerswho were doing everything in their power to lower un sprung mass in an effort to get tires to say in intimate contact with the roughest terrain at the highest possible speeds In both worlds the ability to accurately track the impossible landscape is the ultimate goal minimalmovingmassassociatedwithacompliants...

Page 4: ...ring either another XP 25 phono stage or a Pass Laboratories XP 20 pre amplifier without degradation of measured or perceived performance Consumers frequently ask us if they may substitute a Din 25 cable of their choice for the one Pass Laboratories supplies The answer is yes provided that cable carries all the necessary legal approvals For those of you so inclined please pick a shielded and filte...

Page 5: ...ge indicated on the product is consistent with the nominal voltage supplied at your location All XP25 products are protected by a voltage specific type 3AG fuse 1 4 x 1 1 4 For 100 Volts ac and 120 Volts ac the fuse will be 1 amp for 220 Volts ac and 240 Volts ac the fuse will be 1 2 amp In all instances the fuse will have a slow blow time constant Substitution of another time constant other than ...

Page 6: ...h a series loading of 47k ohms and 100 pf of parallel capacitance Like gain these settings too are selectable from the front panel of the XP25 Presuming 47k ohm in the case of moving magnet greatest benefit comes from exploring the pallet of available capacitive loading choices Infrequently moving magnet cartridges will perform best at other than 47k ohm but that would be an exception Moving Coil ...

Page 7: ...ds best for the listener Specifically in selecting a cartridge load we will be listening for a compromise loading which sounds best across the whole audio spectrum and specifically not that loading which optimizes one cut on one LP The front panel controls of the XP 25 load each channel of the phono cartridge independently through closely to preserve the best possible spatial elements of recording...

Page 8: ...peat the listening test I am sure you get the idea it is not complicated but it can be time consuming Capacitive loading follows the same rigor and affects the finer points of resistive loading The final and optimal setting will require alternating between resistive and reactive loading elements peaking each element in turn until no further gains are achieved Capacitive loading will not affect mov...

Page 9: ...sight but are no substitute for human judgment of that which is pleasant As in art classic audio components are the results of individual and collective efforts that reflect a coherent underlying goal and philosophy by the major participants If successful they make both a subjective and objective statement of quality which is meant to illicit appreciation in the final product It is essential that ...

Page 10: ...an relax and focus on the results WARRANTY Please check with the factory authorized distributor in the country where you are purchasing this product for specific warranty information All Pass Laboratories products purchased new from an authorized Pass Laboratories dealer in NorthAmerica are covered by a transferable limited 3 year warranty This warranty includes all parts and labor charges incurre...

Page 11: ...ld a modified product be returned to the factory for repair the owner will be required to pay all necessary charges for the repair in addition to those charges required to return the product to it s original configuration In the case of safety issues no product shall be returned to the customer without those safety issues being corrected to the most recent accepted standards Removaloralterationofo...

Page 12: ...dB 47 Single ended 66 dB 60 SE 76 dB 70 SE RIAA response plus minus 1 dB 20 20 KHz Distortion 005 THD 1mV MC input 002 THD 10mV MM input Maximum Output 22 volts rms Output Impedance 150 150 ohms Input Impedance 100pF 750pF on any input 30 ohm 47K ohm any input Unweighted Noise 93 dB ref 10 mV MM 85 dB ref 1 mV MC Power consumption 25 watts Dimensions 2 17 W x 12 D x 4 H Shipping Weight 55 pounds i...

Page 13: ... one that is fully safety rated by the necessary local authority Power Cord Protection Power supply cords should be routed so that they are not likely to be walked on abraded or pinched by items placed on or against them paying particular attention to cords where they enter plugs or exit from a device Never under any circumstance insert a cut or damaged power cord into a mains power socket Power a...

Page 14: ...14 XP 25 Owner s Manual ...