background image

OPERATOR TROUBLESHOOTING

                

  

 PROBLEM

   

 

 

 

            

CORRECTIVE ACTION

Fasteners will not drive completely into wood.

Fasteners penetrate properly during normal 
operation, but won't drive fully at faster speeds.

Fasteners drive too deeply into wood.

Fastener jams in nose of tool.

Tools skips during operation - no fasteners are 
driven from time to time.

Tool operates, but no fasteners are driven.

Air leaks at cap when tool is connected to air. 

Adjust work contacting element (retract length).

Increase air pressure (do not exceed 120 psi).

Increase air flow to tool -- use larger air lines 
(3/8 inch ID minimum).

Adjust work contacting element (extend length).

Reduce air pressure.

Open front guide latch, release jammed fastener, 
and close latch securely.

Check magazine for proper fasteners. Magazine fol-
lower should slide freely. Clean as needed to remove 
debris.

Make sure correct fasteners are being used. 
Use fasteners that meet Paslode

®

 specifications only.

Increase air flow to tool -- use larger air lines 
(3/8 ID minimum).

Adjust work contacting element where available.

Check magazine for proper fasteners. Fasteners 
should slide freely with no follower pressure.

Open front guide latch or loosen magazine knob and 
check for jams or debris in the nose area. Clear as 
necessary.

Increase air pressure (do not exceed 120psi).

Tighten capscrews.

Summary of Contents for F400S

Page 1: ...P Operating and Maintenance Manual PNEUMATIC TOOLS 403606 18 08 07...

Page 2: ...length in inches that can be used with the tool 00 S 00 P Type of tool P powerpack DL double length Gauge of fastener Indicates crown size W wide S standard I intermediate N narrow Maximum fastener l...

Page 3: ...ur new tool Also read Paslode s warranty statement in the back of this manual Even though Paslode ia a leader in the power fastening business we continually strive to find new and better ways of impro...

Page 4: ...a safety mechanism called a work contacting element to help prevent accidental firing Never tamper with disable or remove the work contacting element Do not use the tool unless the work contacting el...

Page 5: ...he bottom of each branch line A refrigerant type dryer is installed on the system Air hoses are kept as short as practical A regular maintenance program is followed Outdoor Air System Installation Be...

Page 6: ...ed We can use the following example 10 tools X 30 fasteners minute tool X 1 2 X 0 051scfm 100psi 18 36 scfm This number is found in the Air Consumption Chart In this example using the air consumption...

Page 7: ...ir hose requirements and lengths In general no other special installation is required 5 If the operator is working at a bench or table it is usually best to run the air line underneath the bench A sma...

Page 8: ...tool trigger to avoid unintentional fastener discharge Sequential Operation Silver Trigger The sequential operating kit prevents succesive or bounce driving Depress the work contacting element and ho...

Page 9: ...Remove the retainer from a nail coil and place the nail coil in the magazine with the tips of the nails against the loading tray and with about 4 inches of coil unwound Step No 4 Slide the free strip...

Page 10: ...he nails The tool is now ready for use RHP 350 PowerMaster Plus Strip Nailers Step No 1 Grasp the nailer handle firmly Pull the magazine follower all the way to the rear of the magazine until it is la...

Page 11: ...ep No 3 When the follower reaches the reload area marked on the side of the magazine you may insert a new strip of nails When the follower arrow reaches the lockout area the tool automatically locks t...

Page 12: ...the tank will keep the air free of frost Testing the Tool After Servicing After replacing any part or parts it is important to check the tool for proper operation This ensures that the tool was put t...

Page 13: ...Keep tool lubricated Prevent clogging of filter with dirt Prevent air leakage and pro mote efficient operation Promote operator safety and efficient tool operation Prevent jamming of fasteners Assure...

Page 14: ...air lines 3 8 inch ID minimum Adjust work contacting element extend length Reduce air pressure Open front guide latch release jammed fastener and close latch securely Check magazine for proper fastene...

Page 15: ...TOOL WARRANTY TOOL WARRANTY AND LIMITATIONS An Illinois Tool Works Company 888 Forest Edge Drive Vernon Hills Illinois 60061 P 13...

Page 16: ...P An Illinois Tool Works Company 888 Forest Edge Drive Vernon Hills Illinois 60061 www paslode com Printed in U S A 2007 Illinois Took Works Inc...

Reviews: