M o d e l   N o . P S - 2 2 2 2

  S u g g e s t e d   L a b o r a t o r y   A c t i v i t i e s

7

Xplorer GLX Setup

Make sure that the Xplorer GLX is turned on, and insert the General Flow Sensor into one of the PASPORT input 
ports at the top of the GLX.

In the GLX Home screen, use the cursor buttons to highlight “Sensors” 
and then press the “Checkmark” button.

In the General Flow Sensor screen, use the “Up” and “Down” cursor 
buttons to select a choice such as “Pitot Air” and then press the 
“Checkmark” button to change the selection from “Visible” to Not Vis-
ible”, or 

vice versa

.

Press the “Home” button to return to the Home screen, and use the cur-
sor buttons to select a display. Press the “Checkmark” button to open 
your display choice.

Care

After use with fluids, care should be taken to remove all fluid from the 
hoses that attach the sensor to the Venturi Tube or the Pitot Tube. Fluids left 
in the hoses may migrate into the sensor and cause damage over time.

Suggested Laboratory Activities

Visit the PASCO Web site at www.pasco.com and enter PS-2222 in the Search window. Click the User Resources 
tab to see the Downloads menu for the downloadable suggested activity write-ups. Activities may be similar to 
the following:

Derivation of the Venturi Pressure Velocity Relationship

Pump Delivery Studies - Measure fluid velocity as a function of pump speed and working head

Measurement of Velocity and Pressure Losses in Piping Networks (when used with the PS-2107 Absolute 
Pressure Sensor and the ME-2224 Pressure Tap)

Measurement of Velocity and Pressure Losses in Valves (when used with the PS-2107 Absolute Pressure 
Sensor and the ME-2224 Pressure Tap)

Summary of Contents for PASPort PS-2222

Page 1: ...able PS 2500 Required Items Information PASCO Interface see www pasco com PASCO Data Acquisition Software see www pasco com Accessories used with the sensor Accessories used with the sensor ME 2220 Ve...

Page 2: ...values for flow velocity or volumetric flow assuming standard temperature and pres sure The units of measure are selectable as metric or non metric Venturi Tube ME 2220 The General Flow Sensor measur...

Page 3: ...uch as PASCO Capstone Select the type of fluid air or water Set up a data display in the software Click Record press the button on the GLX or touch Start to begin recording data Specifications The pre...

Page 4: ...pressure port is higher than the pressure applied to the high pressure port may result in permanent damage to the sensor Changing Fluid Use Care must be taken when changing from measurement in liquid...

Page 5: ...ars with the interface s icon Click the Data Summary icon in the Tools palette to open the Data Summary panel The panel lists the sensor s measure ments for example Differential Pressure Diff Press kP...

Page 6: ...tion Zero drift can occur due to tempera ture position or hose placement changes SPARKvue Setup When SPARKvue starts up it shows the Home Screen for a moment and then shows a screen that lists the par...

Page 7: ...fluids care should be taken to remove all fluid from the hoses that attach the sensor to the Venturi Tube or the Pitot Tube Fluids left in the hoses may migrate into the sensor and cause damage over...

Page 8: ...are trademarks or registered trademarks of PASCO scientific in the United States and or in other countries For more information visit www pasco com legal Product End of Life Disposal Instructions Thi...

Reviews: