background image

www.parweld.co.uk

www.parweld.co.uk

4

1.0 Safety Precautions

ELECTRIC SHOCK can kill.

Touching live electrical parts can cause fatal shocks or severe burns. 
The electrode and work circuit is electrically live whenever the output 
is on. The input power circuit and machine internal circuits are also 
live when power is on. 

Do not touch live electrical parts.

Wear dry, sound insulating gloves and body protection.

Insulate yourself from work and ground using dry insulating mats 
or covers big enough to prevent any physical contact with the work 
ground.

Additional safety precautions are required when any of the following 
electrically hazardous conditions are present: in damp locations 

or while wearing wet clothing; on metal structures such as floors, 
gratings, or scaffolds; when in cramped positions such as sitting, 

kneeling, or lying; or when there is a high risk of unavoidable or 
accidental contact with the work piece or ground.

Disconnect input power before installing or servicing this equipment. 
Lockout/tagout input power according to Safety Standards.

Properly install and ground this equipment according to national and 
local standards.

Always verify the supply ground - check and ensure that input power 
cable ground wire is properly connected to ground terminal in the 
receptacle outlet.

When making input connections, attach proper grounding conductor 

first - double-check connections.

Frequently inspect input power cable for damage or bare wiring - 
replace cable immediately if damaged - bare wiring can kill.

Turn off all equipment when not in use.

Do not use worn, damaged, under sized, or poorly spliced cables.

Do not drape cables over your body.

If earth grounding of the work piece is required, ground it directly 
with a separate cable.

Do not touch electrode if you are in contact with the work, ground, or 

another electrode from a different machine.

Use only well-maintained equipment. Repair or replace damaged 
parts at once. Maintain unit according to manual.

Wear a safety harness if working above floor level.

Keep all panels and covers securely in place.

Clamp work cable with good metal-to-metal contact to work piece or 
worktable as near the weld as practical.

Insulate work clamp when not connected to work piece to prevent 
contact with any metal object.

Welding produces fumes and gases. Breathing these fumes and 
gases can be hazardous to your health.

FUMES AND GASES can be hazardous.

Keep your head out of the fumes. Do not breathe the fumes.
If inside, ventilate the area and/or use local forced ventilation at the 
arc to remove welding fumes and gases.

If ventilation is poor, wear an approved respirator.

Read and understand the Material Safety Data Sheets (MSDS’s) and 
the manufacturer’s instructions for metals, consumable, coatings, 
cleaners, and de-greasers.

Work in a confined space only if it is well ventilated, or while wearing 

an air-supplied respirator. Always have a trained watch person 
nearby. Welding fumes and gases can displace air and lower the 
oxygen level causing injury or death. Be sure the breathing air is 
safe.

Do not weld in locations near de-greasing, cleaning, or spraying 
operations. The heat and rays of the arc can react with vapours to 
form highly toxic and irritating gases.

Do not weld on coated metals, such as galvanized, lead, or cadmium 
plated steel, unless the coating is removed from the weld area, the 
area is well ventilated, and while wearing an air-supplied respirator. 

The coatings and any metals containing these elements can give off 

toxic fumes if welded.

ARC RAYS can burn eyes and skin.

Arc rays from the welding process produce intense, visible and 
invisible (ultraviolet and infrared) rays that can burn eyes and skin. 

Sparks fly off from the weld.

Wear an approved welding helmet fitted with a proper shade of filter 

lense to protect your face and eyes when welding or watching

Wear approved safety glasses with side shields under your helmet.

Use protective screens or barriers to protect others from flash, glare 

and sparks; warn others not to watch the arc.

Wear protective clothing made from durable, flame resistant material 

(leather, heavy cotton, or wool) and foot protection. Welding on 
closed containers, such as tanks, drums, or pipes, can cause them 

to blow up. Sparks can fly off from the welding arc. The flying sparks, 
hot work piece, and hot equipment can cause fires and burns. 

Accidental contact of electrode to metal objects can cause sparks, 

explosion, overheating, or fire. Check and be sure the area is safe 

before doing any welding.

WELDING can cause fire or explosion.

Remove all flammables within 10m of the welding arc. If this is not 

possible, tightly cover them with approved covers.

Do not weld where flying sparks can strike flammable material.

Protect yourself and others from flying sparks and hot metal.

Be alert that welding sparks and hot materials from welding can 
easily go through small cracks and openings to adjacent areas.

SAFETY

Summary of Contents for XTS 163

Page 1: ...OPERATOR MANUAL ISSUE 4 XTS 163 XTS 163 DV...

Page 2: ...maintenance this equipment should provide years of reliable service All our systems conform to ISO9001 2008 and are independently audited by NQA The entire product range carries the CE mark and is con...

Page 3: ...ing Connection 6 5 4 Output Polarity Connections 6 5 5 Torch Installation 7 5 6 Work Return Lead Connection 7 6 0 Operation 7 6 1 MMA Welding Guide 7 6 2 Basic Tig Welding Guide 7 7 0 Fault Finding 8...

Page 4: ...health FUMES AND GASES can be hazardous Keep your head out of the fumes Do not breathe the fumes If inside ventilate the area and or use local forced ventilation at the arc to remove welding fumes and...

Page 5: ...damage hearing Wear approved ear protection if noise level is high Shielding gas cylinders contain gas under high pressure CYLINDERS can explode if damaged Protect compressed gas cylinders from exces...

Page 6: ...late The XTS163 machine should only be used on 230v supply Refer to the specifications table for voltage tolerances The XTS 163 DV will automatically switch between 110 or 230V input without adjustmen...

Page 7: ...per fusion of weld and base metal Types of electrodes Arc welding electrodes are classified into a number of groups depending on their applications There are a great number of electrodes used for spec...

Page 8: ...c Wrong electrode angle d Travel speed of electrode is too high e Scale or dirt on joint surface a Use larger electrodes and preheat the plate b Increase welding current c Adjust angle so the welding...

Page 9: ...dges of weld or excessive burn through Welding current is too high Decrease weld current Description Possible Cause Remedy Weld bead too small or insufficient penetration or ripples in bead are widely...

Page 10: ...n the primary supply voltage b Switch on the welding power source c Have a qualified service engineer repair the connection Maximum output welding current cannot be achieved with nominal mains supply...

Page 11: ...t connections Stock Code Description Maximum Outlet Pressure E700140 Argon Preset Regulator 3 0 Bar E700141 Argon Indicator Regulator 3 0 Bar E700113 1 Gauge Argon 30 lpm ow E700123 2 Gauge Argon 30 l...

Page 12: ...rch c w 2 Piece Power Cable and dinse connection WP17V 12 2 IX WP17V 25 2 IX Valved Flexible neck Tig Torch c w 2 Piece Power Cable and dinse connection WP17VFX 12 2 IX WP17VFX 25 2 IX B 1 2 5 9 10 13...

Page 13: ...ens Body 040 1 0mm Bore 45V25 Gas Lens Body 1 16 1 6mm Bore 45V26 Gas Lens Body 3 32 2 4mm Bore 45V27 Gas Lens Body 1 8 3 2mm Bore Standard Gas Lens Cup Stock Code Description I 54N18 Standard Gas Len...

Page 14: ...h all homogeneous component parts being controlled to ensure material contents as per the list below Cadmium 0 01 by weight Lead 0 1 by weight Mercury 0 1 by weight Hexavalent chromium 0 1 by weight P...

Page 15: ...t such defects by suitable repair or replacement at Parweld s sole option of any components or parts of the product determined by Parweld to be defective Parweld makes no other warranty express or imp...

Page 16: ...Parweld Limited Bewdley Business Park Long Bank Bewdley Worcestershire England DY12 2TZ tel 44 1299 266800 www parweld co uk info parweld co uk...

Reviews: