background image

Chapter 2  Operation  

 

User Manual, MAR-5915-2x 
User Manual 

 

 

Page 20 of 40 

MNL-0655-01  Rev A6 

ECO-5592 

05 Feb 19 

 

Vertical Mounting 

To install the DuraMAR5915-2X vertically on a mounting surface: 

14.  Create a hole pattern on the mounting surface that matches the pattern shown in Figure 3.  The 

mounting holes are 0.27” in diameter. 

15.  Attach the baseplate to the mounting surface using the four mounting holes.  Attachment screws 

should be 1/4-20.   

 

 

Important!  

Ensure that mounting screw length allows proper thread engagement of the mounting hardware. 

 

 

Figure 3.  Mounting Holes 

 

 

 

Summary of Contents for DuraMAR 5915-2X

Page 1: ...USER MANUAL Parvus DuraMAR 5915 2X Rugged Cisco 5915 Mobile Access Router combined with Cisco ESS 2020 L2 Ethernet Switch MNL 0655 01 Rev A6 ECO 5592 Effective 05 Feb 19 ...

Page 2: ... of Curtiss Wright This document contains proprietary information that is protected by copyright All rights are reserved No part of this document may be photocopied reproduced or translated into another language without the prior written consent of Curtiss Wright Contact Information Defense Solutions Division Curtiss Wright 3222 S Washington St Salt Lake City Utah USA 84115 Phone 1 801 483 1533 To...

Page 3: ... Loading the ROU IOS Image After Zeroization 16 Loading the ROU IOS Configuration After Zeroization 17 Loading the SWI IOS Image After Zeroization 17 Installation 19 Orientation 19 Choosing a Mounting Location Thermal Considerations 19 Vertical Mounting 20 Horizontal Mounting 21 Grounding 22 Chapter 3 Connector and LED Descriptions 23 ROU ring 23 Connector Identification and Mapping 23 J1 PWR Pino...

Page 4: ...ge 4 of 40 MNL 0655 01 Rev A6 ECO 5592 05 Feb 19 Shock 37 Vibration 37 Humidity 37 Sealing 37 Altitude 37 EMI EMC 37 Input Voltage 38 Chapter 5 Troubleshooting 39 Product Identification 39 Technical Assistance 39 Returning for Service 39 Chapter 6 Contact Info 40 ...

Page 5: ...ring cables 11 Figure 2 SWI ring cables 11 Figure 3 Mounting Holes 20 Figure 4 Side Mounting Holes 21 Figure 5 Rear View 22 Figure 6 MAR 5915 2x Connectors 23 Figure 7 Connector J1 Power 24 Figure 8 Connector J2 ETH 0 25 Figure 9 Connector J3 CON 26 Figure 10 J2 LED Mapping to J2 Signal Name and Cisco Port Name 27 Figure 11 Front Panel Dimensions 36 ...

Page 6: ...eatures that are unique to the combined system Description of Safety Symbols The following symbols are used in this manual to indicate important information and potentially dangerous situations Warning Danger electrical shock hazard Personal injury or death could occur Also damage to the system connected peripheral devices or software could occur if the warnings are not followed carefully Caution ...

Page 7: ...AR 5915 0X and DuraNET 30 2020 by combining them in a single system An internal connection links these two components MAR 5915 port FE 0 4 is internally connected to ESS 2020 port FE 18 The 5915 router is physically housed in the DuraSTAX ring labeled ROU hereafter referred to as the ROU ring The ESS 2020 is physically housed in the DuraSTAX ring labeled SWI hereafter referred to as the SWI ring ...

Page 8: ...tion Rugged MIL STD Design Qualified for MIL STD 810G and DO 160G conditions temp shock vibration humidity altitude dust water ingress Qualified for MIL STD 461F and DO 160G EMI EMC Conducted Radiated Emissions Susceptibility and MIL STD 1275 704 Power Input and Transient Protections Filtered transient protected power supply for aircraft and vehicle use Extended temperature open architecture PC104...

Page 9: ...nse for 5 25 or 50 users Product Number Description MAR 5915 20 DuraMAR 5915 Router w ESS 2020 Switch MAR 5915 00 DUNET 30 2020 01 2020LANBase IOS 5915 BaseIOS MAR 5915 21 DuraMAR 5915 Router w ESS 2020 Switch MAR 5915 01 DUNET 30 2020 01 2020LANBase IOS 5915 AdvIOS MAR 5915 22 DuraMAR 5915 Router w ESS 2020 Switch MAR 5915 02 DUNET 30 2020 01 2020LANBase IOS 5915 AdvIOS CME5 MAR 5915 23 DuraMAR 5...

Page 10: ...Chapter 1 Introduction User Manual MAR 5915 2x User Manual Page 10 of 40 MNL 0655 01 Rev A6 ECO 5592 05 Feb 19 Block Diagrams ...

Page 11: ...the system These cables are suitable for bench top testing and proof of concept setups The same cable set works with all 2X models Final installation should use custom cables designed for the target environment Refer to Chapter 3 Connector and LED Descriptions for information required to design custom cables Figure 1 ROU ring cables Figure 2 SWI ring cables power cable shown is not part of the SWI...

Page 12: ...ize Test cable DB 9 1 ROU RS 232 serial console port cable Flying leads 2 ROU SWI Zeroize and Ground wire CBL 1554 03 38999 J6 SWI Gigabit Ethernet port and console port DB 9 1 SWI Console port RJ 45 1 SWI Gigabit Ethernet port 1 GbE1 CBL 2549 01 38999 J7 SWI Gigabit Ethernet port and 10 100Base T port RJ 45 1 SWI 10 100Base T port 17 RJ 45 1 SWI Gigabit Ethernet port 2 GbE2 CBL 2550 01 38999 J8 S...

Page 13: ... for ROU configuration or J6 J9 for SWI configuration Note To use the J9 console remove the cover plate over connector J9 Save the cover and screws J9 should be covered when not in use Connect CBL 1536 01 between J9 and the host PC serial port Caution Do not connect to both SWI console ports at the same time J6 Console and J9 Console are the same port Connecting to both ports will result in an ele...

Page 14: ...is shipped with a Cisco factory installed IOS on both the router and switch portions Custom network configuration is the responsibility of the customer This manual is not intended as a guide to the Cisco 5915 ESS2020 or IOS That information is available directly from Cisco Systems at www cisco com The Cisco website is also the source for Cisco IOS files ...

Page 15: ...SS2020 SWI From an IOS prompt enter the following commands Switch enable Switch conf t Switch config service declassify erase flash Switch config exit Switch Initiating Zeroization Caution Triggering zeroization from either ring ROU or SWI will cause the entire system to be zeroized If you only want to zeroize one system ensure that zeroization is enabled on only that ring see above The hardware s...

Page 16: ...en the tftp server on the host PC 6 Open a terminal emulator on the host PC Note The Solarwinds TFTP server has a file transfer size limit of 32 MB This is normally not a problem for the base IOS here But if the Advanced IOS or other file in excess of 32 MB is transferred the file is too large for Solarwinds The TFTPD32 TFTP server handles the larger file size without a problem Load Procedure Ther...

Page 17: ... if ip address 192 168 100 10 255 255 255 0 Router config if no shut Router config if exit Router config exit Router copy tftp 192 168 100 11 filename startup config Destination filename startup config 10 Make sure that the ok xxxx bytes message is displayed If not fix the error and repeat the copy tftp command 11 Power off the system 12 Power on the system 13 After the reload completes press Ente...

Page 18: ...ccessfully copied to flash c2020 universalk9 mz 150 2 EC bin switch set BAUD 9600 Now illegible characters will appear in the TeraTerm window when enter is pressed In TeraTerm go to Setup Serial Port and change Baud rate to 9600 OK confirm switch prompt is visible again Now from switch prompt boot from flash using the following command switch boot flash c2020 universalk9 mz 150 2 EC bin SWI should...

Page 19: ...mal Considerations The DuraMAR5915 2X enclosure is highly efficient at removing heat from the inside of the unit to the outside of the finned enclosure It is best to mount the unit on a thermally cool thermally conductive surface to keep the overall temperature as low as possible Every effort has been made to meet stringent thermal performance criteria as outlined in the specifications However it ...

Page 20: ...ng surface 14 Create a hole pattern on the mounting surface that matches the pattern shown in Figure 3 The mounting holes are 0 27 in diameter 15 Attach the baseplate to the mounting surface using the four mounting holes Attachment screws should be 1 4 20 Important Ensure that mounting screw length allows proper thread engagement of the mounting hardware Figure 3 Mounting Holes ...

Page 21: ...zontal 1 Create a hole pattern on the mounting surface that matches the pattern shown in Figure 4 The mounting holes are 0 33 in diameter 2 Attach the switch to the mounting surface using the two side mounting holes Attachment screws should be 5 16 18 Important Ensure that mounting screw length allows proper thread engagement of the mounting hardware Figure 4 Side Mounting Holes 400 ...

Page 22: ...ind grounding hole for attachment of a grounding cable using a 1 4 20 bolt is provided on the rear of each ring of the system It is recommended that you use only one grounding hole Choose the grounding hole that allows the shortest grounding cable length Caution The grounding lug tie holes are shallow 0 375 Select the proper screw length for your grounding application and avoid over tightening Fig...

Page 23: ...connector part numbers along with suggested mating connector details It also provides LED indicator descriptions Figure 6 MAR 5915 2x Connectors ROU ring Connector Identification and Mapping Connector Label Description Part Number Mating Connector J1 PWR 12 36 VDC 28v Nominal Power Input D38999 20FA98PN D38999 26FA98SN J2 ETH 0 2X 10 100 Switched 2X 10 100 Routed D38999 20FC35SN D38999 26FC35PN J3...

Page 24: ... Page 24 of 40 MNL 0655 01 Rev A6 ECO 5592 05 Feb 19 J1 PWR Pinouts J1 provides power input signals for 28V power to the Parvus Power Supply Figure 7 Connector J1 Power P N D38999 20FA98PN Shell Size 9 J1 Signal Name Description 38999 Pin V 28 VDC A V 28 RTN C Chassis Chassis B ...

Page 25: ...ctor Pinout The ROU ring provides two switched and two routed ports to the outside Ports 0 and 1 are the routed ports ports 2 and 3 are the switched ports Note Port 4 is internally connected to SWI port FE18 J2 Signal Name Description 38999 Pin ETH 0_PORT0_TX 10 100 TX 0 1 ETH 0_PORT0_TX 10 100 TX 0 2 ETH 0_PORT0_RX 10 100 RX 0 3 ETH 0_PORT0_RX 10 100 RX 0 4 ETH 0_PORT1_TX 10 100 TX 1 5 ETH 0_PORT...

Page 26: ...r on the DuraMAR 5915 front panel socket side appears as an exact mirror of the picture on the left P N D38999 20FB35SN Shell Size 11 J3 Signal Name Description 38999 Pin Zeroize Zeroization of System 2 GND Signal Ground Used for zeroization 1 CONS_TXD_RS232 Console Transmit Data 10 CONS_DTR_RS232 Console Data Terminal Ready 8 CONS_RTS_RS232 Console Ready to Send 9 CONS_RXD_RS232 Console Receive D...

Page 27: ...o router Steady green light indicates steady state IOS load completed and running R0 R1 Routed Ethernet ports 0 0 and 0 1 on connector J2 Steady green light indicates link status S0 S1 S2 Switched Ethernet ports 0 2 0 3 and 0 4 on connector J2 Steady green light indicates link status Figure 10 shows the mapping of Cisco port names to J2 signal names and to the LED labels on the front panel Figure ...

Page 28: ... connector on the SWI Ring identified in Figure 6 Connector Label Part Number Function Cisco Port Mapping Mating Connector J6 ETH CON D38999 20FB35SA 1x Gigabit Ethernet Console G0 1 Console D38999 26FB35PA J7 ETH2 D38999 20FB35SB 1x Gigabit Ethernet 1x 10 100Base T G0 2 F0 17 D38999 26FB35PB J8 ETH3 D38999 20FF35SN 16x 10 100Base T F0 1 F0 16 D38999 26FF35PN J9 CON WD9F3C8AT7SU AA Console and Zer...

Page 29: ...ntained in the J6 connector J6 9 through J6 13 Caution Do not connect to both console ports at the same time J6 Console and J9 Console are the same port Connecting to both ports will result in an electrical conflict on both connections This is a rear view The connector on the DuraMAR 5915 front panel socket side appears as an exact mirror of the picture on the left Note J6 on MAR 5915 2x is functi...

Page 30: ...on and this documentation refers to these four pairs as pair Ax Ax Ax pair Bx Bx Bx pair Cx Cx Cx and pair Dx Dx Dx J2 has an additional Fast Ethernet port requiring only two pairs of wires Rx Rx and Tx Tx This is a rear view The connector on the DuraMAR 5915 front panel socket side appears as an exact mirror of the picture on the left J7 Pin Signal 1 GE2_Ax 2 GE2_Ax 3 GE2_Bx 4 GE2_Bx 5 GE2_Cx 6 G...

Page 31: ...16 This is a rear view The connector on the DuraMAR 5915 front panel socket side appears as an exact mirror of the picture on the left J8 Pin Signal J8 Pin Signal J8 Pin Signal 1 Tx16 23 Rx3 45 Tx9 2 Tx16 24 Rx3 46 Tx9 3 Rx16 25 Tx4 47 Rx9 4 Tx1 26 Tx4 48 Rx9 5 Tx1 27 Tx5 49 Rx8 6 Tx15 28 Tx5 50 Rx8 7 Rx16 29 No Connect 51 Tx10 8 Rx1 30 Rx5 52 Tx10 9 Rx1 31 Rx5 53 Rx13 10 Tx2 32 Rx4 54 Rx13 11 Tx2...

Page 32: ...N Pinouts Caution Do not connect to both console ports at the same time J6 Console and J9 Console are the same port Connecting to both ports will result in an electrical conflict on both connections Insert arrangement front view J9 Pin Signal 1 No Connect 2 TXD_OUT 3 RXD_IN 4 No Connect 5 GND 6 No Connect 7 CTS_IN 8 RTS_OUT 9 Zeroize ...

Page 33: ...3 u ab Ethernet Fast Ethernet Gigabit Ethernet IEEE 802 3ad Link Aggregation LACP Resilient Ethernet Protocol REP IEEE 802 1D w s STP RSTP MSTP IEEE 802 1p Layer2 COS Prioritization IEEE 802 1q VLAN IEEE 802 1AB Link Layer Discovery Protocol LLDP VLAN Trunking Protocol v2 VTPv2 Network Time Protocol NTP UDLD Flex Links VLAN Trunking Protocol v3 VTPv3 EtherChannel Voice VLAN Multicast IGMPv1 v2 v3 ...

Page 34: ...e Agent Syslog Response Time Reporter NTP Client TFTP Client and Server DHCP Client and Server DHCP Relay HSRP Network Address Translation Address Conservation DHCP Client Address Negotiation Easy IP Phase I Voice Support Cisco Unified Comms Manager Express for Remote IP Telephony Command Control Comms 5 25 User License Support Advanced IOS add on option Routing Bridging IPv4 and IPv6 Routing IPv6...

Page 35: ...e CCEVS EAL and Federal Information Processing Standard FIPS 140 2 Certification Pending on Cisco 5915 Router Card building on Legacy Cisco 3200 EAL3 Certification QoS Quality of Service QoS Classification Prioritization of Data guaranteeing determinism for mission critical data Generic Traffic Shaping Class Based Ethernet Matching Mobile Access Routing 802 1p Class of Service Committed Access Rat...

Page 36: ... Max Qualified to MIL STD 704F and MIL STD 1275D Steady State Voltage Ripple Surges and Spikes Galvanic Isolation 1500 VDC Dimensions Figure 3 Mounting Holes and Figure 11 provide the physical dimensions of the DuraMAR 5915 2X Dimensions 4 98 H x 6 75 D x 6 25 W 12 65cm H x 17 15cm D x 15 88cm W D 8 25 including connectors mounting tabs Figure 11 Front Panel Dimensions Physical Weight 6 6 lbs 3 kg...

Page 37: ... 516 DO 160G Vibration Random Vibration 10Hz to 2000Hz 3 Axes Jet Helo Tracked Vehicle Profile 3 Axes MIL 810G Meth 514 Humidity Humidity Up to 95 RH 40C Non Condensing per MIL STD 810G Method 507 5 Procedure II Aggravated Sealing Water Immersion 1 Meter 30 Minutes per IP67 and MIL STD 810G Method 512 5 Procedure I Blowing Sand and Dust per MIL STD 810G Method 510 5 DO 160G Section 12 Cat S sealed...

Page 38: ...fications User Manual MAR 5915 2x User Manual Page 38 of 40 MNL 0655 01 Rev A6 ECO 5592 05 Feb 19 Input Voltage Meets MIL STD 704F MIL STD 1275D and DO 160G Section 16 Cat A Section 17 Cat B and Section 18 Category R ...

Page 39: ... Service Contract that also includes an extension of the standard hardware warranty period In either case you need to provide the CSN Cisco Serial Number from the 5915 and ESS2020 in order to obtain coverage For either ring issue the show version command The CSN is returned as the Processor Board ID in both cases Returning for Service Before returning any Parvus product please fill out a Return Ma...

Page 40: ...info Defense Solutions Division Curtiss Wright 3222 S Washington St Salt Lake City Utah USA 84115 801 483 1533 FAX 801 483 1523 Website www curtisswrightds com parvus Sales 1 800 483 3152 or 801 483 1533 slp_sales curtisswright com Product Technical Support 1 801 433 6322 slp_tsupport curtisswright com Customer Feedback slp_feedback curtisswright com ...

Reviews: