![Partner SP-630-Q Service Manual Download Page 17](http://html1.mh-extra.com/html/partner/sp-630-q/sp-630-q_service-manual_3947437017.webp)
17
Jumper
Setting
Description
JP3
(COM3 Power Select Jumper)
1-2 Close
COM3 Pin 9: 5V
3-4 Close (Default)
COM3 Pin 9: RING
5-6 Close
COM3 Pin 9: 12V
JP4
(COM4 Power Select Jumper)
1-2 Close
COM4 Pin 9: 5V
3-4 Close (Default)
COM4 Pin 9: RING
5-6 Close
COM4 Pin 9: 12V
JT1
(Touch Panel USB or PS/2 Interface
Select Jumper)
1-2 Close
PS/2 Interface
2-3 Close (Default)
USB Interface