Parry
-British Built for Purpose
IN146-9
10
Technical Information
High Rate (All figures are NET)
Low Rates: (All figures are NET)
Injector Sizes
Gases
Burner Injector
Natural G20
193
Propane G31
119
Gas
Operating Pressure
Total Heat Input
NATURAL G20
20mb/8” W.G.
4.72 KW = 16,122Btu/h
PROPANE G31
37mb/14.8” W.G.
4.98 KW = 17,015 Btu/h
Gas Rate
M³/HR
FT³/HR
LB/HR
KG/HR
NATURAL G20
0.500
17.65
PROPANE G31
0.204
7.204
0.859
0.390
AIR FLOW RATE
FOR COMBUSTION
20m3/hr
5
180
Gas
Operating Pressure
Total Heat Input
NATURAL G20
20mb/8” W.G.
3.194 KW = 10,596 Btu/h
PROPANE G31
37mb/14.8” W.G.
4.774 KW = 15,412 Btu/h
Gas Rate
M³/HR
FT³/HR
LB/HR
KG/HR
NATURAL G20
0.338
11.787
PROPANE G31
0.195
6.897
0.822
0.373