background image

CONNECT  TO

Green fan wire ....Bare supply wire

Red or Black receiver wire(ACIN L)....Red or Black supply wire

White receiver wire(AC IN N)....White supply wire

White receiver wire(TO MOTOR N)....White fan wire

Black receiver wire(TO MOTOR L)....Black fan wire

Blue receiver wire(FOR LIGHT) ....Blue light wire

CAUTION: Ceiling Angle Shall Not Exceed 30 Degrees,

                 For Mounting Controller,Model RE-022

WHITE

BLACK

ANT

INPUT

OUTPUT

WHITE

WHITE

BLUE

BLUE

BLACK

RED or BLACK

RECEIVER

CANOPY

CANOPY

RECEIVER

(FIG.4)

WIRE NUT

Use wire connecting nuts 

supplied with the remote 

controller.

(FIG.3)

Use wire connecting nuts supplied with the fan

FROM POWER SOURCE 

AC 110- 120 VOLT 60Hz 

3.5AMPS.

ANTENNA PUT

 

AT OUTSIDE

 

OF CANOPY BOX CAN GET

MORE OPERATION

 

DISTANCE

FAN MUST BE KEPT AT THE HIGH SPEED

LIGHT MUST BE KEPT AT THE ON P0SITION

Remote controller

GENERAL INFORMATION

INSTRUCTION OF INSTALLATIONAND OPERATION

1.SETTING THE CODES
  To set the codes, perform the following steps:
A.Setting the codes on the transmitter:
  a.Remove battery cover.Press firmly on the arrow and slide battery cover off.
  b.Slide code switches to your choice of up or down position.(Factory setting is all up. Do not use this position.Use a
      Small screwdriver or ball point pen to slide firmly up or down (Figure 1)).
B.Setting the codes on the receiver:
  The Learn Key must be pressed with in 30 seconds, after pressing the Power button.
  If not, please press the Power button to restart.
  Keep pressing the button learn key in excess of 3 second it becomes a LEARN status.
  The receiver can remember the last codes status. The light flash two times.

2.INSTALLING RECEIVER IN CEILING FAN
A.Safety precautions:
WARNING: HIGH VOLTAGE! Disconnect power by 
removing fuse or switching off circuit breaker.
Do not use with solid state fans.
Electrical wire must meet all local and national 
electrical code requirements.
Supply for fan must be 110/120 volt, 60Hz. Maximum 
fan motor amps: 1.0,Maximum light watts: 180
incandescent or ballast and LED.
Otherwise power can cause serious injury or death.
B.lnstalling receiver in fan:
  a.Remove power from the circuit.
  b.Remove ceiling fan canopy from the mounting
  bracket.
  c.Disconnect existing wiring between ceiling fan and
  Supply in electrical junction box.
  d. Make connections as follows, using the wire nuts
  supplied:

This remote controller is desianed to separatelv control vour ceilina fan speed and light on and off.
There are four buttons(HI,MED, LoW,OFF) to control the speed of the fan and off.
The light button will control the light on and off.
The red indicator on the transmitter will light when one of the five buttons is pressed.

Installation & Operating Instructions for the

Parrotuncle Owner's Installation ,Manual

WARNING: SHUT POWER OFF AT FUSE OR CIRCUIT BREAKER

F6305110V/F6305BK110V

Summary of Contents for F6305110V

Page 1: ...CEILING FAN...

Page 2: ...F6305110V F6305BK110V Installation Operating Instructions for the Parrotuncle Owner s Installation Manual WARNING SHUT POWER OFF AT FUSE OR CIRCUIT BREAKER...

Page 3: ...must UL listed and marked suitable for use with the model fan you are installing Switches must be UL general use switches Refer to the instructions packaged with the light kits and switches for prope...

Page 4: ...CONTROL 1PCS Installation Operating Instructions for the Parrotuncle Owner s Installation Manual WARNING SHUT POWER OFF AT FUSE OR CIRCUIT BREAKER Balanced parts package 4 2h 4h 8h 1 2 3 White Black o...

Page 5: ...Installation Operating Instructions for the Parrotuncle Owner s Installation Manual WARNING SHUT POWER OFF AT FUSE OR CIRCUIT BREAKER Finish Finish F6305110V F6305BK110V...

Page 6: ...1 2 3 Installation Operating Instructions for the Parrotuncle Owner s Installation Manual WARNING SHUT POWER OFF AT FUSE OR CIRCUIT BREAKER washers Outlet box spring washer F6305110V F6305BK110V...

Page 7: ...Finish Installation Operating Instructions for the Parrotuncle Owner s Installation Manual WARNING SHUT POWER OFF AT FUSE OR CIRCUIT BREAKER Finish F6305110V F6305BK110V...

Page 8: ...BLACK RED or BLACK RECEIVER CANOPY WIRE NUT Use wire connecting nuts supplied with the remote controller Use wire connecting nuts supplied with the fan FROM POWER SOURCE AC 110 120 VOLT 60Hz 3 5AMPS C...

Page 9: ...fecting your comfort B Cool weather Reverse An upward air ow moves warm air off the ceiling This allows Reverse you to set heating unit on a lower setting without affecting your comfort Installation O...

Page 10: ...the receiver The Learn Key must be pressed with in 30 seconds after pressing the Power button If not please press the Power button to restart Keep pressing the button learn key in excess of 3 second i...

Page 11: ...frequency energy and if not installed and used in accordance with the instructions may casue harmful interference to radio communications However there is no guarantee that interference will not occur...

Page 12: ...for the Parrotuncle Owner s Installation Manual WARNING SHUT POWER OFF AT FUSE OR CIRCUIT BREAKER size of product F6305110V F6305BK110V 1320 52 278 10 19 20 321 12 3 5 483 19 335 13 1 5 284 11 1 5 132...

Page 13: ...et to the same frequency Check the main and branch circuit fuses or breakers If using a Variable Speed Wall Switch ensure it is speci cally designed for use with a ceiling fan Check the line wire conn...

Page 14: ...re from the center of the selected blade to point on the ceiling Rotate the fan un e next blade is oned and repeat the measurement using the same point from the ceiling for every blade Measurements sh...

Page 15: ...l noticeable 4 If the blade wobble is still noticeable interchanging two adjacent side by side blades can redistribute the weight and possibly result in smoother operation WARNING TO REDUCE THE RISK O...

Page 16: ......

Reviews: