Installation & Operating Instructions for the
Owner's Installation ,Manual
WARNING:SHUT POWER OFF AT FUSE OR CIRCUIT BREAKER
INSTALLING THE DOWNROD
When hanging the Fan REMEMBER to turn off the power. Follow the steps below to hang your fan properly:
1)Remove the bolt, lock pin and set screws from the top of the housing
2)Route wires exiting from the top of the fan motor through the bolt&pin , canopy and then through the ball / downrod.
3)Align the holes at the bottom of the down rod with the holes in the coupling on top of the top housing .
4)Carefully insert the Bolt through the holes in the Coupling and down rod. Be careful not to jam the Bolt against the wiring inside the downrod. Insert the locking pin through the hole near the end
of the Bolt until it snaps into its locked position.
5)Tighten two set screws on top of the fan housing fimnly
CHANGING THE OOWNROD (OPTIONAL)
NOTE: Your fan comes with a 25cm downrod attached to the hanger ball.
In addition, a 10cm downrod has been provided to be used in case the
ceiling is lower.In this case, perform the following steps for correct
installation:
1. Remove the hanger ball from down rod by loosening the setscrew at the
top of the downrod which holds the hanger ball to the downrod.
2. Slide the hanger ball down the down rod and remove the support pin.
3. Insert the support pin in the holes at the top of the 10cm downrod and
slide the hanger ball up the 10cm downrod. Make sure the support pin is
properly seated in the grooves in the top of the hanger ball.
4.Tighten the set crews firmly .
SAFETY CABLE INSTALLATION
Canopy
Downrod&
-----"===r----,-�
=":'�'=----
Decorative
hanger ball
Canopy cover
Coupling cover
Bolt-�=
,_ __ Lock pin
o
o1------- Set screw
Coupling--�����-
For Canadian installation and for USA fan and light kit combinations over 35 lbs, the safety cable must be installed into the house structure beams. Make sure that when the safety cable is fully
extended the lead wires are longer than the cable and no stress is placed on the lead wires. Note: If Installing The Secondary Support Safety Cable in the U.S., Do Not Remove Knockouts In The Outlet
Box.
'
,,,.
INSTALLING THE FAN TO MOUNTING BRACKET ON CEILING
WARNING To avoid possible electrical dhock. be sure electricity is turned off at the main fuse box before wiring.
1.lnstall ball end of downrod into mounting bracket opening. Align (engage) slot on ball with tab on mounting bracket.
Warning: Failure to align slot on ball with tab may result in serious injury.
2.Slide the canopy up to ceiling and align the keyhole slots on the canopy with the preassembled screws on the hanger
bracket. Twist clockwise untill locks.Tighten two screws securely.
3.Attach the decorative canopy cover to the bottom of the canopy by pressing it until it locks.
TT
USING YOUR CEILING FAN
REMOTE CONTROL
Turn on the power and check the operation of the fan
1- Fan Shutdown
2- Speed Controlle
3- Lamp Switch
4- Timer(2H,4H,8H)
Reverse function
Slide the forward/reverse
switch on the coupling to
get desired airflow
direction