Menu Descriptions
6400
4
w w w . p a r r i n s t . c o m
39
Hydrogen Entry Mode:
This key steps through
the options for entering hydrogen content for
calculating the net heat of combustion either
manually through the touch screen or auto-
matically through the balance (USB) port.
Oxygen Entry Mode:
This key steps through
the options for entering oxygen content for
calculating the net heat of combustion either
manually through the touch screen or auto-
matically through the balance (USB) port.
Nitrogen Entry Mode:
This key steps through
the options for entering nitrogen content for
calculating the net heat of combustion either
manually through the touch screen or auto-
matically through the balance (USB) port.
Auto Sample ID Controls:
Accesses sub-menu for
controlling the automatic assignment of sample
identification numbers.
Auto Sample ID Controls
Automatic Sample ID:
When set to ON the unit
will automatically assign sample identification
numbers in accordance with parameters set by
the other three keys on this menu. When set
to OFF, the user manually enters each sample
ID when prompted to do so.
Auto Sample ID Prefix:
An entry here will be
used as a prefix for all sample IDs, if the Auto-
matic Sample ID is set to ON. Press this key
to access a sub-menu for entering an alphanu-
meric prefix.
Next Auto Sample ID Number:
Establishes the
initial sample number for a series of tests and
then shows the next sample ID which will be
assigned. Used when the Automatic Sample
ID is set to ON. Press this key to access a sub-
menu for entering a numeric increment.
Auto Sample ID Increment:
Establishes the in-
crement between sample numbers; used when
the Automatic Sample ID is set to ON. Press
this key to access a sub-menu for entering a
numeric increment.
Sample Weight Warning Above:
This key displays
and leads to a sub-menu used to set the maximum
allowable sample weight (including spike) in grams.
A warning will be given if sample weights above
this value are entered.
Spike Weight Entry Mode:
This key steps through
the options for entering spike weights either manu-
ally through the touch screen, balance (USB) port or
network.
Sulfur Entry Mode:
This key steps through the op-
tions for entering the sulfur correction value either
manually through the touch screen or automatically
through the balance (USB) port.
Moisture Entry Mode:
This key steps through the
options for entering the moisture percentage wheth-
er manually through touch screen or automatically
through the balance (USB) port.
Moisture Data Entry Controls
Summary of Contents for 6400
Page 2: ......
Page 9: ...w w w p a r r i n s t c o m 7 Notes 6400...
Page 17: ...w w w p a r r i n s t c o m 15 Notes 6400 1...
Page 19: ...w w w p a r r i n s t c o m 17 Notes 6400 2...
Page 49: ...w w w p a r r i n s t c o m 47 Notes 6400 5...
Page 71: ...w w w p a r r i n s t c o m 69 Notes 6400 9...
Page 81: ...w w w p a r r i n s t c o m 79 Notes 6400 12...
Page 86: ...14 Drawings P a r r I n s t r u m e n t C o m p a n y 84 Figure 14 2 6400 Cutaway Right...
Page 87: ...Drawings 6400 14 w w w p a r r i n s t c o m 85 Figure 14 3 6400 Cutaway Left...
Page 91: ...Drawings 6400 14 w w w p a r r i n s t c o m 89 Figure 14 8 A1456DD Rinse Valve Assembly...
Page 95: ...Drawings 6400 14 w w w p a r r i n s t c o m 93 Figure 14 13 A1268DD Stirrer Motor and Mount...
Page 96: ...14 Drawings P a r r I n s t r u m e n t C o m p a n y 94 Figure 14 14 6400 Bucket Assembly...
Page 99: ...Drawings 6400 14 w w w p a r r i n s t c o m 97 Figure 14 17 A1450DD Bomb Head Assembly View 1...
Page 102: ...14 Drawings P a r r I n s t r u m e n t C o m p a n y 100 Figure 14 20 Wiring Diagram...
Page 103: ...Drawings 6400 14 w w w p a r r i n s t c o m 101 Figure 14 21 Wiring Diagram...
Page 104: ...14 Drawings P a r r I n s t r u m e n t C o m p a n y 102 Figure 14 22 Fuse Diagram...
Page 105: ...w w w p a r r i n s t c o m 103 Notes 6400 14...
Page 109: ......
Page 110: ...587M R03 02 11 14...