21
To adjust the fuel consumption per hour, start the unit and wait for the display to show heat level 3. Go to menu
and the combustion calibration will appear. The factory setting default should be zero.
The thermostat mode is very simple and regulates automatically the room temperature. For pellets, the heat level
1 is the minimum and the heat level 3 or 4 are used for the maximum power. For corn or wheat, the heat level 2 is
used for minimum power and the heat level 3 or 4 is used for maximum power. When the red heat level number 3
or 4 appears, the thermostat is on full power.
Caution:
When the thermostat mode is activated without a thermostat installed, the heat level 1 will appear after
the startup.
Note: Refer to the page 15 on tabs B to activate a thermostat when the unit is functioning.
Refer to page 13 on table 5 when unit is in standby mode.
How to program the fuel consumption on the control panel
Results (hopper empty)
Display values
19 hours
-1
18 hours
-2
17 hours
-3
21 hours
+1
22 hours
+2
23 hours
+3
Thermostat mode
Reference table for heat level 3
Programming fuel consumption
Thermostat functions
Paromax created the mixing mode on normal operation to disturb the fuel on heat level 1, 2 and 3.
Every 12 hours on the same heat level setting, the mixing mode well increase by 1 heat level for 5 minutes to
regenerate the fuel bed. After 5 minutes, the heat level returns to your selected level.
Refer to page 15 on table B to activate the mixing mode when the unit is running and press
Enable mixing mode.
An X will appear in the box.
Note: The mixing mode is deactivated when the thermostat mode is activated
Mixing mode