18
1
1
4
4
.
.
I
I
n
n
s
s
t
t
a
a
l
l
l
l
i
i
n
n
g
g
t
t
h
h
e
e
s
s
t
t
o
o
v
v
e
e
-
-
p
p
o
o
w
w
e
e
r
r
c
c
o
o
n
n
n
n
e
e
c
c
t
t
i
i
o
o
n
n
s
s
F
F
i
i
t
t
t
t
i
i
n
n
g
g
o
o
n
n
a
a
P
P
o
o
w
w
e
e
r
r
S
S
u
u
p
p
p
p
l
l
y
y
C
C
a
a
b
b
l
l
e
e
W
W
A
A
R
R
N
N
I
I
N
N
G
G
:
:
I
I
n
n
s
s
t
t
a
a
l
l
l
l
a
a
t
t
i
i
o
o
n
n
M
M
U
U
S
S
T
T
O
O
N
N
L
L
Y
Y
b
b
e
e
c
c
a
a
r
r
r
r
i
i
e
e
d
d
o
o
u
u
t
t
b
b
y
y
a
a
q
q
u
u
a
a
l
l
i
i
f
f
i
i
e
e
d
d
a
a
p
p
p
p
r
r
o
o
v
v
e
e
d
d
i
i
n
n
s
s
t
t
a
a
l
l
l
l
e
e
r
r
,
,
i
i
e
e
.
.
a
a
n
n
E
E
l
l
e
e
c
c
t
t
r
r
i
i
c
c
i
i
a
a
n
n
.
.
Using a screwdriver, prize open tabs of the Terminal board cover.
Remove the wire clamp screw.
Fasten the wires beneath the corresponding screw heads, using brass ‘bridge’ for single phase supply.
Fasten cable clamp and close the cover of the terminal board.
The AC power supply should be 220-240 V. For electric cookers, the minimum 45A fuse, or at least 45A a
distribution circuit breaker.
W
W
a
a
r
r
n
n
i
i
n
n
g
g
:
:
C
C
o
o
n
n
n
n
e
e
c
c
t
t
t
t
h
h
e
e
p
p
o
o
w
w
e
e
r
r
c
c
o
o
r
r
d
d
m
m
u
u
s
s
t
t
b
b
e
e
i
i
n
n
a
a
c
c
c
c
o
o
r
r
d
d
a
a
n
n
c
c
e
e
w
w
i
i
t
t
h
h
t
t
h
h
e
e
i
i
n
n
s
s
t
t
r
r
u
u
c
c
t
t
i
i
o
o
n
n
s
s
l
l
i
i
s
s
t
t
e
e
d
d
i
i
n
n
t
t
h
h
e
e
t
t
a
a
b
b
l
l
e
e
b
b
e
e
l
l
o
o
w
w
Wire cross-sectional
area(mm2)
Connection mode
L
L
1
1
L
L
2
2
L
L
3
3
N
N
E
E
1
1
N
N
~
~
Min6
-
-
-
-
Min6
Min6
2
2
N
N
~
~
Min2.5
Min2.5
-
-
Min6
Min6
3
3
N
N
~
~
Min2.5
Min1.5
Min1.5
Min6
Min6
C
C
o
o
n
n
n
n
e
e
c
c
t
t
i
i
n
n
g
g
t
t
h
h
e
e
s
s
u
u
p
p
p
p
l
l
y
y
c
c
a
a
b
b
l
l
e
e
t
t
o
o
t
t
h
h
e
e
m
m
a
a
i
i
n
n
s
s
Install an approved circuit breaker with a minimum contact opening of 3 mm, between the appliance and the mains fuse
box .The circuit breaker should be sized according to the load and should comply with current regulations in New Zealand
(the earth wire should not be interrupted by the circuit breaker).
The supply cable should be positioned so that it does not reach a temperature of more than 50 °C with respect to the room
temperature, anywhere along its length Before switching fuse ON in meter-box check:
Earth continuity. The electrical safety of this appliance can only be guaranteed if the cooker is correctly installed
and earthed, in compliance with regulations on electrical installations.
The electrical capacity of the system and sockets will support the maximum power of the appliance, as indicated
on the data plate
Go to section “Installing your new cooker”
NOTE
: All Upright cookers must comply to local regulations AS/NZS 3000:2007 guidelines. Qualified Electrician will have a
copy of these guides that must be adhered to.