11
GB IE
CY
After switching on the device, wait until the
device has reached its max. speed. Only
then must you start with the grinding.
The disk will continue to
run after the equipment is
switched off. There is a risk
of injury.
Test run:
Before starting work and after each
change of grinding disk, carry out a test
run of at least 60 seconds with no load.
Switch off the equipment immediately if the
disk runs lumpy, substantial vibrations oc-
cur, or abnormal noises are generated.
Sharpening drills
Drills with a diameter of 3-10 mm can be
sharpened.
1. Mount the selected sharpener
(see Mounting sharpener).
2. Remove the drill holder (14) from
the sharpener.
3. Insert the drill into the drill holder
(14).
4. Insert the drill holder (14) into the
adjusting device (15).
5. Push the drill to the front into the
V-nut up to the metal stop. The
cutting edges of the drill must fit
closely to the metal surfaces.
6. Using the knurled nut fasten the
drill for drill-fastening (12).
7. Remove the drill holder (14) and
insert it into the rotatable drill
mount (11).
8. Check the alignment of the drill.
The cutting edges of the drill must
be touching the grinding wheel
(10).
9. Switch the device off and grind
the drill.
10. Switch the device off and wait for
the grinding wheel (10) to stop.
11. Remove the drill holder (14)
and insert it into the rotatable
drill mount (11) by rotating in
by 180°. Using the same adjust-
ment, you can grind the opposite
cutting edge of the drill.
12. Switch the device off and grind
the drill.
13. Switch the device off and wait for
the grinding wheel (10) to stop.
Sharpening picks and chisels
1. Mount the selected sharpener
(see Mounting sharpener).
2. Place the blade on the tool table
(6) so that the end to be sharp-
ened fits closely to the edge of
the tool table (6). The magnetic
holder (5) keeps the blade in po-
sition.
3. For small picks, use the spacer
(4).
4. Select the angle according to the
existing bevel angle (angle of the
bevelled edge).
5. Release the retaining screw for
the angular adjustment (7) and
turn the tool table (6) into posi-
tion.
6. Tighten the retaining screw for
angular adjustment (7) again.
7. Switch the device on and move
the tool table (6) equally back
and forth along the grinding
wheel (10).
8. Always use light pressure while
sharpening and slowly push the
blade towards the grinding wheel
Summary of Contents for PSS 65 A1
Page 3: ...1 5 4 7 8 9 10 11 12 13 6 3 2 14 15 10 13 16...
Page 19: ...19 GR CY 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16...
Page 21: ...21 GR CY...
Page 22: ...22 GR CY...
Page 23: ...23 GR CY FI 30mA...
Page 24: ...24 GR CY A O...
Page 25: ...25 GR CY 9 1 2 13 3 4 5...
Page 27: ...27 GR CY 2 6 6 5 3 4 4 5 7 6 6 7 7 6 10 8 10 9 10 10 1 2 3 10 4 5 6 7 10 1 2 3 4 10 5 6...
Page 28: ...28 GR CY 7 10 8 9 10 16 10 1 16 2 10 3 10 16 4 60...
Page 29: ...29 GR CY 10...
Page 31: ...31 GR CY 3 16 16 10...
Page 32: ...32 GR CY 3 270702...
Page 52: ...52...
Page 53: ...53 Exploded Drawing Explosionszeichnung o informative informativ PSS 65 A1 20150824 rev02 gs...
Page 54: ...14 15 14 12...
Page 55: ......