40
GB
HF-arc is not created?
The burner switch is faulty.
Soldering point on the burner
switch or plug loosened.
Valve/manometer fails.
Replace electrode.
Bad ignition?
Burner wear parts damaged
or worn.
Change wear parts.
Plasma burner
8
is not ready
for operation?
Current switch is
switched off.
Air transmission is restricted.
Workpiece is not connected
to the earthing terminal.
Switch the current switch
to “on”.
Another indication of this is
a green flame. Check the
air supply.
Check the connections.
Sparks fly upwards, instead of
down through the material?
The plasma beam does not
penetrate the material.
Burner sleeve
8c
is too far
away from the material.
Material was probably not
earthed properly.
Lifting speed is too quick.
Increase the current.
Reduce the gap between the
burner sleeve
8c
and
material.
Check the connection for
correct earthing.
Reduce the speed.
Initial cut but not completely
drilled through?
Potential connection
problem.
Check all connections.
Slag formation on interfaces?
Tool/material creates heat.
Cutting speed too low or
current too high.
Plasma burner component
parts are worn
8b
,
8c
,
8d
,
8e
.
Allow the material to cool
down and then continue
cutting.
Increase the speed and/or
reduce the current until the
slag has been reduced to a
minimum.
Check and replace worn
parts.
Consumables wear quickly?
Performance was
overstretched.
Arc control time exceeded.
Incorrect plasma burner
assembly.
Insufficient air supply,
pressure too low.
Faulty air compressor.
Material too thick, increase
the angle to avoid material
from being blown back into
the tip.
Do not control the arc for
more than 5 seconds. You
can also start with contact
between the burner sleeve
8c
and metal or with a
3 mm distance to the metal.
Check the performance of
the external air compressor
and make sure the pressure
is 4–4.5 bar.